The BIDMC PPG and Respiration Dataset is a small, carefully annotated PhysioNet dataset for estimating respiratory rate from the PPG. It was contributed by Marco Pimentel, Alistair Johnson, Peter Charlton and David Clifton and published on PhysioNet as version 1.0.0 on June 20, 2018.
The recordings were extracted from the much larger MIMIC-II matched waveform database and come from critically ill patients during hospital care at the Beth Israel Deaconess Medical Centre in Boston, MA, USA. There are 53 recordings, each 8 minutes long. Each one contains physiological signals sampled at 125 Hz (PPG, impedance respiratory signal and ECG), physiological parameters sampled at 1 Hz (heart rate, respiratory rate and SpO2), fixed parameters such as age and gender, and manual breath annotations. Two annotators marked individual breaths using the impedance respiratory signal, which gives an unusually clean reference for respiratory rate.
The dataset first appeared in a 2016 paper by Pimentel and colleagues on estimating respiratory rate from pulse oximeters, published in IEEE Transactions on Biomedical Engineering 64(8):1914-1923. That paper proposed using multiple autoregressive models of different orders to find the dominant respiratory frequency in three respiratory-induced variations of the PPG (frequency, amplitude and intensity). Tested on two datasets with 95 eight-minute recordings in total, it achieved accuracy comparable to existing methods while keeping over 90% of the input data. Because it ships with synchronized PPG, ECG and breath labels, BIDMC is now a common test set for respiratory rate estimation and also appears as a downstream task in PPG foundation model papers such as SiamQuality.
The data comes in three formats: WFDB (the PhysioNet standard, five files per recording), CSV (separate files for breaths, signals, numerics and fixed variables) and a Matlab file compatible with the RRest toolbox of respiratory rate algorithms. The total uncompressed size is 207.7 MB. It is open access on PhysioNet under the Open Data Commons Attribution License v1.0, so you can download it without credentialing; cite both the PhysioNet record and the original paper.
Recordings
53, each 8 minutes
Formats
WFDB, CSV, Matlab (RRest compatible)
Size
207.7 MB; DOI 10.13026/C2208R
Source
MIMIC-II matched waveform database, Beth Israel Deaconess Medical Centre, Boston
This dataset contains signals and numerics extracted from the much larger MIMIC II matched waveform Database, along with manual breath annotations made from two annotators, using the impedance respiratory signal.
Verbatim fromPhysioNet· Licence: Open Data Commons Attribution License v1.0
BIDMC PPG and Respiration (Pimentel 2016 / PhysioNet): overview
The BIDMC PPG and Respiration Dataset contains 53 eight-minute recordings from critically ill patients at Beth Israel Deaconess Medical Centre, extracted from the MIMIC II matched waveform database. Each has PPG, impedance respiration and ECG at 125 Hz, 1 Hz heart rate, respiratory rate and SpO2, age and gender, and individual breaths annotated by two annotators. It was built to evaluate respiratory-rate estimation from the PPG (Pimentel et al.) and is open on PhysioNet under ODC-By.
Mainly for estimating respiratory rate from the PPG; it also has ECG, HR and SpO2.
What is the sampling rate of BIDMC?
Waveforms (PPG, ECG, impedance respiration) at 125 Hz; numerics such as HR, RR and SpO2 at 1 Hz.
How long are the BIDMC recordings?
Each of the 53 recordings is 8 minutes long.
Is BIDMC free to use commercially?
It is under the Open Data Commons Attribution License v1.0, which allows any use with attribution.
How do I download the BIDMC dataset?
Open access on PhysioNet (https://physionet.org/content/bidmc/1.0.0/) under ODC-By 1.0. No credentialed account is required.
What is the BIDMC PPG and Respiration Dataset?
It is a PhysioNet dataset of 53 eight-minute ICU recordings with PPG, ECG and impedance respiration at 125 Hz plus manual breath annotations from two annotators, built for respiratory rate estimation.
BIDMC vs MIMIC PERform?
BIDMC is a small set of 53 recordings with manual breath labels drawn from MIMIC-II. MIMIC PERform is a larger collection of PPG, ECG and other signals from MIMIC-III built for broader benchmarking.
What are BIDMC benchmark results?
The original paper's autoregressive method gave a median mean absolute error of 1.5 breaths per minute on one of its two test datasets with a 32 second window, while keeping over 90% of the input data.
Cite this dataset
This citation is the paper recorded with this dataset. Check it against the publisher before submitting.
Pimentel, M. A. F., Johnson, A. E. W., Charlton, P. H., Birrenkott, D., Watkinson, P. J., Tarassenko, L., & Clifton, D. A. (2017). Toward a Robust Estimation of Respiratory Rate From Pulse Oximeters. IEEE Transactions on Biomedical Engineering, 64(8), 1914–1923. https://doi.org/10.1109/tbme.2016.2613124
Pimentel, Marco A. F., Alistair E. W. Johnson, Peter H. Charlton, Drew Birrenkott, Peter J. Watkinson, Lionel Tarassenko, and David A. Clifton. 2017. "Toward a Robust Estimation of Respiratory Rate From Pulse Oximeters." IEEE Transactions on Biomedical Engineering 64 (8): 1914–1923. https://doi.org/10.1109/tbme.2016.2613124.
Pimentel, M. A. F., Johnson, A. E. W., Charlton, P. H., Birrenkott, D., Watkinson, P. J., Tarassenko, L. and Clifton, D. A. (2017) 'Toward a Robust Estimation of Respiratory Rate From Pulse Oximeters', IEEE Transactions on Biomedical Engineering, 64(8), pp. 1914–1923. doi: 10.1109/tbme.2016.2613124.
Pimentel, Marco A. F., et al. "Toward a Robust Estimation of Respiratory Rate From Pulse Oximeters." IEEE Transactions on Biomedical Engineering, vol. 64, no. 8, 2017, pp. 1914–1923. https://doi.org/10.1109/tbme.2016.2613124.
M. A. F. Pimentel et al., "Toward a Robust Estimation of Respiratory Rate From Pulse Oximeters," IEEE Transactions on Biomedical Engineering, vol. 64, no. 8, pp. 1914–1923, 2017, doi: 10.1109/tbme.2016.2613124.
@article{pimentel2017toward,
title = {{Toward a Robust Estimation of Respiratory Rate From Pulse Oximeters}},
author = {Pimentel, Marco A. F. and Johnson, Alistair E. W. and Charlton, Peter H. and Birrenkott, Drew and Watkinson, Peter J. and Tarassenko, Lionel and Clifton, David A.},
year = {2017},
journal = {IEEE Transactions on Biomedical Engineering},
volume = {64},
number = {8},
pages = {1914--1923},
publisher = {Institute of Electrical and Electronics Engineers (IEEE)},
doi = {10.1109/tbme.2016.2613124}
}
Cite the ChatPPG record
Cite the dated snapshot 2026-10 for a fixed, reproducible version. Please also cite the original publications listed above.
APA
ChatPPG. (2026). BIDMC PPG and Respiration (Pimentel 2016 / PhysioNet): dataset record (Version 2026-10) [Data set]. ChatPPG Research Hub. https://chatppg.com/research/datasets/bidmc
BibTeX
@misc{chatppg_dataset_bidmc,
author = {{ChatPPG}},
title = {{BIDMC PPG and Respiration (Pimentel 2016 / PhysioNet): dataset record}},
year = {2026},
month = nov,
version = {2026-10},
howpublished = {\url{https://chatppg.com/research/datasets/bidmc}},
note = {ChatPPG Research Hub, Snapshot 2026-10, https://chatppg.com/research/snapshots/2026-10}
}
CITATION.cff
cff-version: 1.2.0
message: "If you use this resource, please cite it as below."
type: dataset
title: "BIDMC PPG and Respiration (Pimentel 2016 / PhysioNet): dataset record"
authors:
- name: "ChatPPG"
url: "https://chatppg.com/research/datasets/bidmc"
repository-artifact: "https://chatppg.com/research/snapshots/2026-10"
version: "2026-10"
date-released: "2026-11-22"
History
Record updated
Newsletter
Get new PPG datasets, papers and models
Get alerts when new models are benchmarked on BIDMC PPG and Respiration (Pimentel 2016 / PhysioNet), plus the weekly digest.
New datasets, papers and models
Practical guides from the hub
Unsubscribe anytime
The waveform is an illustration of a PPG pulse, not a recording.
Articles and algorithm explainers
Read more about BIDMC PPG and Respiration (Pimentel 2016 / PhysioNet)