Dataset

BIDMC PPG and Respiration (Pimentel 2016 / PhysioNet)

The BIDMC PPG and Respiration Dataset is a small, carefully annotated PhysioNet dataset for estimating respiratory rate from the PPG. It was contributed by Marco Pimentel, Alistair Johnson, Peter Charlton and David Clifton and published on PhysioNet as version 1.0.0 on June 20, 2018. The recordings were extracted from the much larger MIMIC-II matched waveform database and come from critically ill patients during hospital care at the Beth Israel Deaconess Medical Centre in Boston, MA, USA. There are 53 recordings, each 8 minutes long. Each one contains physiological signals sampled at 125 Hz (PPG, impedance respiratory signal and ECG), physiological parameters sampled at 1 Hz (heart rate, respiratory rate and SpO2), fixed parameters such as age and gender, and manual breath annotations. Two annotators marked individual breaths using the impedance respiratory signal, which gives an unusually clean reference for respiratory rate. The dataset first appeared in a 2016 paper by Pimentel and colleagues on estimating respiratory rate from pulse oximeters, published in IEEE Transactions on Biomedical Engineering 64(8):1914-1923. That paper proposed using multiple autoregressive models of different orders to find the dominant respiratory frequency in three respiratory-induced variations of the PPG (frequency, amplitude and intensity). Tested on two datasets with 95 eight-minute recordings in total, it achieved accuracy comparable to existing methods while keeping over 90% of the input data. Because it ships with synchronized PPG, ECG and breath labels, BIDMC is now a common test set for respiratory rate estimation and also appears as a downstream task in PPG foundation model papers such as SiamQuality. The data comes in three formats: WFDB (the PhysioNet standard, five files per recording), CSV (separate files for breaths, signals, numerics and fixed variables) and a Matlab file compatible with the RRest toolbox of respiratory rate algorithms. The total uncompressed size is 207.7 MB. It is open access on PhysioNet under the Open Data Commons Attribution License v1.0, so you can download it without credentialing; cite both the PhysioNet record and the original paper.

Recordings
53, each 8 minutes
Formats
WFDB, CSV, Matlab (RRest compatible)
Size
207.7 MB; DOI 10.13026/C2208R
Source

MIMIC-II matched waveform database, Beth Israel Deaconess Medical Centre, Boston

Signals at 125 Hz

PPG, impedance respiration, ECG; parameters at 1 Hz: HR, RR, SpO2

Manual breath annotations from two annotators

Original description

This dataset contains signals and numerics extracted from the much larger MIMIC II matched waveform Database, along with manual breath annotations made from two annotators, using the impedance respiratory signal.

Verbatim fromPhysioNet· Licence: Open Data Commons Attribution License v1.0

BIDMC PPG and Respiration (Pimentel 2016 / PhysioNet): overview

The BIDMC PPG and Respiration Dataset contains 53 eight-minute recordings from critically ill patients at Beth Israel Deaconess Medical Centre, extracted from the MIMIC II matched waveform database. Each has PPG, impedance respiration and ECG at 125 Hz, 1 Hz heart rate, respiratory rate and SpO2, age and gender, and individual breaths annotated by two annotators. It was built to evaluate respiratory-rate estimation from the PPG (Pimentel et al.) and is open on PhysioNet under ODC-By.

What's inside

Recordings
53 × 8 min
Signals (125 Hz)
PPG (PLETH), impedance respiration (RESP), ECG leads
Numerics (1 Hz)
HR, RR, pulse rate, SpO2
Annotations
Manual breath annotations from two independent annotators
Fixed variables
Age, gender, ward location
Formats
WFDB, CSV and MATLAB (RRest-compatible)

How to access it

Host: PhysioNet

  1. Open access: no account needed.
  2. Download the zip, or stream records with wfdb (pn_dir='bidmc').
  3. Use the .breath annotations as the respiratory-rate reference.

Licence: Open Data Commons Attribution License v1.0 (ODC-By)

What it allows: Any use, including commercial, with attribution.

Load BIDMC PPG and Respiration (Pimentel 2016 / PhysioNet) in Python

Testedpip install wfdb
import wfdb

rec = wfdb.rdrecord("bidmc01", pn_dir="bidmc")        # streams from PhysioNet
print(rec.sig_name, rec.fs, rec.p_signal.shape)        # PPG, ECG, impedance resp at 125 Hz
ppg = rec.p_signal[:, rec.sig_name.index("PLETH,")]
breaths = wfdb.rdann("bidmc01", "breath", pn_dir="bidmc")
print(len(breaths.sample), "manual breath annotations")

Run on 16 Oct 2026: bidmc01 has signals RESP, PLETH, V, AVR, II at 125 Hz, shape (60001, 5), and 335 breath annotations.

Caveats

  • Only 53 short recordings: report subject-level results, not window-level.
  • Patients are critically ill and mostly at rest; do not expect results to transfer to ambulatory wearables.
  • Signal names carry a trailing comma in WFDB (e.g. 'PLETH,').
  • Monitor-derived RR is from impedance and can disagree with the manual breath annotations; use the annotations as reference.

Similar datasets

DatasetSubjectsSignalsLicence
CapnoBase IEEE TBME RR benchmark (Karlen 2013)n/appg, ecg, respCustom terms specific to this dataset
MIMIC PERform35ppg, ecg, resp, abpODbL
VitalDB6,388ppg, ecg, resp, abp, co2CC BY 4.0 (PhysioNet release)
MIMIC-III-Ext-PPG6,189ppg, ecg, resp, abpPhysioNet Credentialed Health Data License 1.5.0

Sources: BIDMC on PhysioNet · Pimentel et al. 2017 · Updated 2026-10-19

BIDMC PPG and Respiration (Pimentel 2016 / PhysioNet): ChatPPG research summary card

Key numbers

53
Subjects
3
Reference labels
SPO2, HR, RESP RATE
1 Hz
Released sampling rate
waveforms 125 Hz; numerics 1 Hz

How it works

How BIDMC PPG and Respiration (Pimentel 2016 / PhysioNet) works: Devices & body sites → Signals recorded → TasksSignals recorded: BIDMC PPG and Respiration (Pimentel 2016 / PhysioNet), 53 subjects · 1 Hz, signals PPG, ECG, SpO₂, Respiration. Tasks: Heart rate; SpO₂.Signals recordedBIDMC PPG and Respiration…53 subjects · 1 HzPPGECGR / IRSpO₂RespirationTasksHeart rateHeart rateSpO₂O₂SpO₂
Sampling
waveforms 125 Hz; numerics 1 Hz
Reference labels
spo2, hr, resp rate
Device roles
Reference PPG · Clinical reference (ECG)

Leaderboard rows· 1

All leaderboards
TaskDatasetMetricValueRank
Heart rate estimationBIDMC PPG and Respiration (Pimentel 2016 / PhysioNet)MAE (bpm) ↓1.227#1 / 1

Papers and models using this dataset· 21

Papers

Show 3 more papers

Models

#9 of 186 most-used datasets by published papers and models · #6 of 88 PPG · #7 of 78 ECG

Browse these 15 papers in the research explorer (filtered to BIDMC PPG and Respiration (Pimentel 2016 / PhysioNet))

FAQ

What is the BIDMC dataset used for?

Mainly for estimating respiratory rate from the PPG; it also has ECG, HR and SpO2.

What is the sampling rate of BIDMC?

Waveforms (PPG, ECG, impedance respiration) at 125 Hz; numerics such as HR, RR and SpO2 at 1 Hz.

How long are the BIDMC recordings?

Each of the 53 recordings is 8 minutes long.

Is BIDMC free to use commercially?

It is under the Open Data Commons Attribution License v1.0, which allows any use with attribution.

How do I download the BIDMC dataset?

Open access on PhysioNet (https://physionet.org/content/bidmc/1.0.0/) under ODC-By 1.0. No credentialed account is required.

What is the BIDMC PPG and Respiration Dataset?

It is a PhysioNet dataset of 53 eight-minute ICU recordings with PPG, ECG and impedance respiration at 125 Hz plus manual breath annotations from two annotators, built for respiratory rate estimation.

BIDMC vs MIMIC PERform?

BIDMC is a small set of 53 recordings with manual breath labels drawn from MIMIC-II. MIMIC PERform is a larger collection of PPG, ECG and other signals from MIMIC-III built for broader benchmarking.

What are BIDMC benchmark results?

The original paper's autoregressive method gave a median mean absolute error of 1.5 breaths per minute on one of its two test datasets with a 32 second window, while keeping over 90% of the input data.

Cite this dataset

This citation is the paper recorded with this dataset. Check it against the publisher before submitting.

Pimentel, M. A. F., Johnson, A. E. W., Charlton, P. H., Birrenkott, D., Watkinson, P. J., Tarassenko, L., & Clifton, D. A. (2017). Toward a Robust Estimation of Respiratory Rate From Pulse Oximeters. IEEE Transactions on Biomedical Engineering, 64(8), 1914–1923. https://doi.org/10.1109/tbme.2016.2613124
Pimentel, Marco A. F., Alistair E. W. Johnson, Peter H. Charlton, Drew Birrenkott, Peter J. Watkinson, Lionel Tarassenko, and David A. Clifton. 2017. "Toward a Robust Estimation of Respiratory Rate From Pulse Oximeters." IEEE Transactions on Biomedical Engineering 64 (8): 1914–1923. https://doi.org/10.1109/tbme.2016.2613124.
Pimentel, M. A. F., Johnson, A. E. W., Charlton, P. H., Birrenkott, D., Watkinson, P. J., Tarassenko, L. and Clifton, D. A. (2017) 'Toward a Robust Estimation of Respiratory Rate From Pulse Oximeters', IEEE Transactions on Biomedical Engineering, 64(8), pp. 1914–1923. doi: 10.1109/tbme.2016.2613124.
Pimentel, Marco A. F., et al. "Toward a Robust Estimation of Respiratory Rate From Pulse Oximeters." IEEE Transactions on Biomedical Engineering, vol. 64, no. 8, 2017, pp. 1914–1923. https://doi.org/10.1109/tbme.2016.2613124.
M. A. F. Pimentel et al., "Toward a Robust Estimation of Respiratory Rate From Pulse Oximeters," IEEE Transactions on Biomedical Engineering, vol. 64, no. 8, pp. 1914–1923, 2017, doi: 10.1109/tbme.2016.2613124.
@article{pimentel2017toward,
  title         = {{Toward a Robust Estimation of Respiratory Rate From Pulse Oximeters}},
  author        = {Pimentel, Marco A. F. and Johnson, Alistair E. W. and Charlton, Peter H. and Birrenkott, Drew and Watkinson, Peter J. and Tarassenko, Lionel and Clifton, David A.},
  year          = {2017},
  journal       = {IEEE Transactions on Biomedical Engineering},
  volume        = {64},
  number        = {8},
  pages         = {1914--1923},
  publisher     = {Institute of Electrical and Electronics Engineers (IEEE)},
  doi           = {10.1109/tbme.2016.2613124}
}

Source metadata: Institute of Electrical and Electronics Engineers (IEEE) (2017) · DOI: 10.1109/tbme.2016.2613124

Last verified Oct 11, 2026

Cite the ChatPPG record

Cite the dated snapshot 2026-10 for a fixed, reproducible version. Please also cite the original publications listed above.

APA

ChatPPG. (2026). BIDMC PPG and Respiration (Pimentel 2016 / PhysioNet): dataset record (Version 2026-10) [Data set]. ChatPPG Research Hub. https://chatppg.com/research/datasets/bidmc

BibTeX
@misc{chatppg_dataset_bidmc,
  author       = {{ChatPPG}},
  title        = {{BIDMC PPG and Respiration (Pimentel 2016 / PhysioNet): dataset record}},
  year         = {2026},
  month        = nov,
  version      = {2026-10},
  howpublished = {\url{https://chatppg.com/research/datasets/bidmc}},
  note         = {ChatPPG Research Hub, Snapshot 2026-10, https://chatppg.com/research/snapshots/2026-10}
}
CITATION.cff
cff-version: 1.2.0
message: "If you use this resource, please cite it as below."
type: dataset
title: "BIDMC PPG and Respiration (Pimentel 2016 / PhysioNet): dataset record"
authors:
  - name: "ChatPPG"
url: "https://chatppg.com/research/datasets/bidmc"
repository-artifact: "https://chatppg.com/research/snapshots/2026-10"
version: "2026-10"
date-released: "2026-11-22"

History

  1. Record updated