Model

Vision4PPG

From “Vision4PPG: Emergent PPG Analysis Capability of Vision Foundation Models for Vital Signs like Blood Pressure”
PPGarXiv preprintOpen codeWeights: not released
PreprintCatalog paper date: 2025Added to atlas: Oct 26, 2026Source

Activity counts measure attention, not model quality. Missing counts are unknown. Publication status follows the linked source; a listed venue alone does not confirm peer review.

Vision4PPG turns 1D PPG into 2D images (STFT magnitude, STFT phase, and recurrence plots) and fine-tunes public vision foundation models, DINOv3 and SigLIP-2 ViT-B (86M parameters), with LoRA. It is an adaptation of vision models, not a PPG-pretrained foundation model. In the authors' Table 1, those vision models win 9 of 14 diastolic/systolic MAE comparisons against fully tuned MOMENT-385M and PPG-GPT-345M; SigLIP-2's Aurora-Oscillometric DBP/SBP MAE is 5.32/18.57 mmHg. The bed BCG set is an exception, where MOMENT and PPG-GPT report lower error than either vision model.

Authors
Kataria, Ermis, Panchumarthi, Wang, Hu (Emory Nursing)
Signals
PPG

arXiv:2510.10366v1 (11 Oct 2025); DOI 10.48550/arXiv.2510.10366

DINOv3 and SigLIP-2 ViT-B, 86M; LoRA on Q, K, V (r=8, alpha=16, dropout 0.05)

Table 1

SigLIP-2 Aurora-Oscillometric DBP/SBP MAE 5.32/18.57 mmHg

Authors

vision FMs win 9/14 DBP/SBP comparisons vs MOMENT-385M and PPG-GPT-345M

Table 2

PPG-GPT HR MAE 7.83 bpm (DaLiA) beats both vision models; DINOv3 respiration MAE 4.41 breaths/min (BIDMC) and SpO2 MAE 2.19% (MIMIC-III)

Code

github.com/saurabh-kataria/Vision4PPG; no weights released with the preprint

At a glance
Type
FM adaptation
Modalities
PPG
Form factor
Imagified PPG vision fm
Parameters
86M
Architecture
DINOv3 and SigLIP-2 ViT-B (86M) with LoRA on Q, K, and V (r=8, alpha=16, dropout 0.05); 1D PPG rendered as STFT magnitude, STFT phase, or recurrence plots
Venue
arXiv preprint
Year
2025
Weights
Not released
Licence
Not reported
Caveats
Not reported
Added
Oct 26, 2026
Updated
Oct 26, 2026

Abstract

Photoplethysmography (PPG) sensor in wearable and clinical devices provides valuable physiological insights in a non-invasive and real-time fashion. Specialized Foundation Models (FM) or repurposed time-series FMs are used to benchmark physiological tasks. Our experiments with fine-tuning FMs reveal that Vision FM (VFM) can also be utilized for this purpose and, in fact, surprisingly leads to state-of-the-art (SOTA) performance on many tasks, notably blood pressure estimation. We leverage VFMs by simply transforming one-dimensional PPG signals into image-like two-dimensional representations, such as the Short-Time Fourier transform (STFT). Using the latest VFMs, such as DINOv3 and SIGLIP-2, we achieve promising performance on other vital signs and blood lab measurement tasks as well. Our proposal, Vision4PPG, unlocks a new class of FMs to achieve SOTA performance with notable generalization to other 2D input representations, including STFT phase and recurrence plots. Our work improves upon prior investigations of vision models for PPG by conducting a comprehensive study, comparing them to state-of-the-art time-series FMs, and demonstrating the general PPG processing ability by reporting results on six additional tasks. Thus, we provide clinician-scientists with a new set of powerful tools that is also computationally efficient, thanks to Parameter-Efficient Fine-Tuning (PEFT) techniques.

Verbatim fromarXiv· arXiv metadata (abstracts are released under CC0)

Vision4PPG: ChatPPG research summary card

Key results

5.32
MAE
SigLIP-2's Aurora-Oscillometric DBP/SBP MAE is 5.32/18.57 mmHg

How it works

How Vision4PPG works: Input signals → Model → Downstream tasksInput signals: PPG (Photoplethysmogram). Datasets: PPG-BP Database (Guilin / Liang 2018), Brno University of Technology Smartphone PPG Database (BUT PPG), VitalVideos, PPG-DaLiA, BIDMC PPG and Respiration (Pimentel 2016 / PhysioNet), Bed-Based BCG (Carlson, K-State). Model: Vision4PPG, 86M parameters (Transformer · Masked reconstruction). Downstream tasks: Blood pressure.Input signalsPPG: PhotoplethysmogramPPGPhotoplethysmogramDatasets: PPG-BP Database (Guilin / Liang 2018), Brno University of Technology Smartphone PPG Database (BUT PPG), VitalVideos, PPG-DaLiA, BIDMC PPG and Respiration (Pimentel 2016 / PhysioNet), Bed-Based BCG (Carlson, K-State)DatasetsPPG-BP Database (Guilin / Liang 2018)…Model×NVision4PPG86M parametersTransformer · Masked reconstructionDownstream tasksBlood pressureBlood pressure

Datasets linked in the hub; pretraining vs evaluation roles follow the paper.

Pretraining data
Public vision corpora (DINOv3 LVD-1689M; SigLIP-2 WebLI), not PPG
Architecture
DINOv3 and SigLIP-2 ViT-B (86M) with LoRA on Q, K, and V (r=8, alpha=16, dropout 0.05); 1D PPG rendered as STFT magnitude, STFT phase, or recurrence plots
Inputs
PPG
Approach
PPG · foundation model · vision · emory · cuffless bp · lora

Datasets· 6

Papers· 1

Cite

APA

Kataria, S., Ermis, A., Panchumarthi, L. Y., Wang, M., & Hu, X. (2025). Vision4PPG: Emergent PPG Analysis Capability of Vision Foundation Models for Vital Signs like Blood Pressure. arXiv preprint. https://doi.org/10.48550/arXiv.2510.10366

BibTeX

@misc{kataria2025vision4ppg,
  title         = {{Vision4PPG: Emergent PPG Analysis Capability of Vision Foundation Models for Vital Signs like Blood Pressure}},
  author        = {Kataria, Saurabh and Ermis, Ayca and Panchumarthi, Lovely Yeswanth and Wang, Minxiao and Hu, Xiao},
  year          = {2025},
  howpublished  = {arXiv preprint},
  doi           = {10.48550/arXiv.2510.10366},
  eprint        = {2510.10366},
  archivePrefix = {arXiv}
}

Built from the hub record. Check it against the publisher before submitting.

History

  1. Added to the ChatPPG research hub