PaperarXiv:2510.10366

Vision4PPG: Emergent PPG Analysis Capability of Vision Foundation Models for Vital Signs like Blood Pressure

Preprint2025Added Oct 26, 2026

  • SK
  • AE
  • LP
  • MW
  • XH

Authors: Saurabh Kataria, Ayca Ermis, Lovely Yeswanth Panchumarthi, Minxiao Wang, Xiao Hu

arXiv preprint

Open code

TL;DR

Vision4PPG turns 1D PPG into 2D images (STFT magnitude, STFT phase, and recurrence plots) and fine-tunes public vision foundation models, DINOv3 and SigLIP-2 ViT-B (86M parameters), with LoRA. It is an adaptation of vision models, not a PPG-pretrained foundation model. In the authors' Table 1, those vision models win 9 of 14 diastolic/systolic MAE comparisons against fully tuned MOMENT-385M and PPG-GPT-345M; SigLIP-2's Aurora-Oscillometric DBP/SBP MAE is 5.32/18.57 mmHg. The bed BCG set is an exception, where MOMENT and PPG-GPT report lower error than either vision model.

  • Authors: Kataria, Ermis, Panchumarthi, Wang, Hu (Emory Nursing)
  • arXiv:2510.10366v1 (11 Oct 2025); DOI 10.48550/arXiv.2510.10366
  • DINOv3 and SigLIP-2 ViT-B, 86M; LoRA on Q, K, V (r=8, alpha=16, dropout 0.05)
  • Table 1: SigLIP-2 Aurora-Oscillometric DBP/SBP MAE 5.32/18.57 mmHg
  • Authors: vision FMs win 9/14 DBP/SBP comparisons vs MOMENT-385M and PPG-GPT-345M
  • Table 2: PPG-GPT HR MAE 7.83 bpm (DaLiA) beats both vision models; DINOv3 respiration MAE 4.41 breaths/min (BIDMC) and SpO2 MAE 2.19% (MIMIC-III)

Abstract

Photoplethysmography (PPG) sensor in wearable and clinical devices provides valuable physiological insights in a non-invasive and real-time fashion. Specialized Foundation Models (FM) or repurposed time-series FMs are used to benchmark physiological tasks. Our experiments with fine-tuning FMs reveal that Vision FM (VFM) can also be utilized for this purpose and, in fact, surprisingly leads to state-of-the-art (SOTA) performance on many tasks, notably blood pressure estimation. We leverage VFMs by simply transforming one-dimensional PPG signals into image-like two-dimensional representations, such as the Short-Time Fourier transform (STFT). Using the latest VFMs, such as DINOv3 and SIGLIP-2, we achieve promising performance on other vital signs and blood lab measurement tasks as well. Our proposal, Vision4PPG, unlocks a new class of FMs to achieve SOTA performance with notable generalization to other 2D input representations, including STFT phase and recurrence plots. Our work improves upon prior investigations of vision models for PPG by conducting a comprehensive study, comparing them to state-of-the-art time-series FMs, and demonstrating the general PPG processing ability by reporting results on six additional tasks. Thus, we provide clinician-scientists with a new set of powerful tools that is also computationally efficient, thanks to Parameter-Efficient Fine-Tuning (PEFT) techniques.

Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Blood pressure

Signals

Keywords

foundation-modelvisionemorycuffless-bplora

Datasets

Models

How it works

How Vision4PPG works: Setup → Method → TargetSetup: PPG-BP Database (Guilin / Liang 2018) (Dataset); Brno University of Technology Smartphone PPG Database (BUT PPG) (Dataset); VitalVideos (Dataset); PPG-DaLiA (Dataset). Method: Vision4PPG. Target: Blood pressure.SetupPPG-BP Database (Guilin / Liang 2018): DatasetPPG-BP Database (Guilin /…DatasetBrno University of Technology Smartphone PPG Database (BUT PPG): DatasetBrno University of Technology…DatasetVitalVideos: DatasetVitalVideosDatasetPPG-DaLiA: DatasetPPG-DaLiADatasetMethodVision4PPGTargetBlood pressureBlood pressure

Cite this paper

APA

Kataria, S., Ermis, A., Panchumarthi, L. Y., Wang, M., & Hu, X. (2025). Vision4PPG: Emergent PPG Analysis Capability of Vision Foundation Models for Vital Signs like Blood Pressure. arXiv preprint. https://doi.org/10.48550/arXiv.2510.10366

BibTeX

@misc{kataria2025vision4ppg,
  title         = {{Vision4PPG: Emergent PPG Analysis Capability of Vision Foundation Models for Vital Signs like Blood Pressure}},
  author        = {Kataria, Saurabh and Ermis, Ayca and Panchumarthi, Lovely Yeswanth and Wang, Minxiao and Hu, Xiao},
  year          = {2025},
  howpublished  = {arXiv preprint},
  doi           = {10.48550/arXiv.2510.10366},
  eprint        = {2510.10366},
  archivePrefix = {arXiv}
}

Built from the hub record. Check it against the publisher before submitting.

Added to the ChatPPG research hub