Who leads on each benchmark

Ranked only within the same task, dataset and metric, using the numbers each paper reports. We never average across benchmarks.

24 boards across 7 tasks

AFib / arrhythmia

Long-term ECG and wrist PPG with annotated AF episodes (AFPPGECG)

Bal. accuracy ↑

0.672

Per-window 10 s, deterministic RR-variability tools, no training; sens 78.3 / spec 56.1; 44 pts; only row on this axis

external-single-lead-af

AUROC ↑

0.957

External single-lead AF

icentia11k

Bal. accuracy ↑

0.678

Same pipeline on ECG; sens 71.9 / spec 63.6; 25 pts; only row on this axis

liu-ppg-arrhythmia-6class

AUROC ↑

0.9697

Window-level six-class Macro AUROC (mean ± 0.0011, 3 seeds) on public Liu PPG arrhythmia dataset; multi-class rhythm, not AF-vs-rest

MIMIC-III-Ext-PPG

Macro-F1 ↑

ECG–PPG multi-class rhythm; SQI-anchored LLM (GPT-5.2); not AF-only

MIMIC PERform

Accuracy ↑

MIMIC 8 s AF, frozen features; accuracy only (no AUROC) — not comparable to AUROC rows; Chronos 0.81 / NormWear 0.78 / PaPaGei 0.66

ptb-xl-rhythm

AUROC ↑

0.987

PTB-XL Rhythm AFIB label, 12-lead, linear probe, 100% labels (Table 3 / D1); MIMIC-IV-ECG pretrain

Stanford wrist PPG AF (DeepBeat)

AUROC ↑

0.883

DeepBeat wrist-PPG AF, full finetune, 5-run mean ±0.019 (npj 2026 BenchECG); same protocol ECGFounder 0.846, ECG-CPC 0.832

0.751

Frozen ECG-pretrained encoder on wrist PPG, 5-run mean ±0.013

Cuffless blood pressure

MIMIC-BP

SDE (mmHg) ↓

6.45 / 4.96

MIMIC-BP SDE SBP/DBP; clinical/lab PPG

PPG-BP Database (Guilin / Liang 2018)

MAE (mmHg) ↓

12.89 / 8.71

PPG-BP (Liang 2018) 2 s segments, frozen features (paper Table 1); finger clinical PPG; DBP Chronos 8.37 better

ring-hgcpt

SDE (mmHg) ↓

5.41 / 4.81

Smart-ring PPG, controlled CV perturbations; LOSO; ME 1.08/0.09

uci-bp

MAE (mmHg) ↓

2.46 / 1.46

UCI cuff-less BP 942 subj; 10 s @ 125 Hz; lab PPG

uci-bp

SDE (mmHg) ↓

4.29 / 3.24

UCI-BP transfer SDE; clinical/lab

Human activity recognition (IMU)

DEO

Bal. accuracy ↑

CABiGRU pre-trained on diffusion-generated smartwatch IMU windows, fine-tuned on real data

har-6bench-avg

Macro-F1 ↑

0.65

Average across 6 subject-disjoint benches — not a single-benchmark rank

PAMAP2

Macro-F1 ↑

75.15 LP / 75.80 FT (%)

LOSO, right wrist 50 Hz 2.56 s, NULL kept; comparator Yuan et al. UKB ResNet18 (harnet-ukb) 77.06 LP / 84.00 FT on same protocol (paper Table 5).

udpad

Accuracy ↑

83.7 / 77

LOSO, 60 participants, offline window classification, 6 microgestures + unknown; μDPad intermediate-fusion VGG-style 1D CNN (670k params), Acc+Gyro+PPG(green+IR); value_secondary = F1 77.0. Online HMM: 78.6% acc, 5.3% FPR (abstract states 3.7% FPR)

Heart rate estimation

EarSet

MAE (bpm) ↓

5.020

PPG-only single selected λ; participant-macro; routing off; ICLR'27 sub

PPG-DaLiA

MAE (bpm) ↓

Paper Table 1 frozen

8 s windows, frozen features (paper Table 1); split unstated; same-paper re-runs NormWear 10.16 / PaPaGei 12.25 / Chronos 12.34

8.936

Frozen linear-probe; paper protocol

9.246

PPG-only — not comparable to PPG+ACC SOTA rows above; ICLR'27 sub

9.27

Paper linear-probe

15.22

Under Pulse-PPG protocol (not PaPaGei original)

Mental workload / stress

WESAD

Accuracy ↑

WESAD subject-independent 5-fold CV; mean Accuracy 90.34%; Stress Recall 94.07%

Binary stress, 8 s, frozen features (paper Table 2); accuracy — not comparable to AUROC rows; PaPaGei 0.80 / Chronos 0.77 / NormWear 0.77

WESAD

AUROC ↑

WESAD subject-independent 5-fold CV; dual ECG+PPG encoders + cross-modal correlation fusion; paper AUC-ROC 97.29%

0.9687

Binary stress; paper non-stress definition

LOSO pooled AUC, BVP 64 Hz 60 s windows, stress from 9 subjects; post hoc; interval-only 0.911–0.933; RF 0.972 transductive z-scoring (not ranked)

binary stress; classical ML on HRV features; PPG features linearly calibrated to ECG space (uncalibrated PPG 0.79; ECG 0.85); 15 subjects

0.8043

Under Pulse-PPG protocol

Potassium estimation

mc-med

Pearson r ↑

0.21

model=AnyPPG; frozen encoder probe, 6,348 encounter-matched ED encounters; falls to 0.05 after age + renal adjustment

Sleep staging

hmc

Bal. accuracy ↑

0.7425

HMC sleep staging, EEG, frozen features + strict linear probe, mean ± sd over 3 pretrain seeds (±0.0045); full fine-tune 0.7669

isruc-s1

Bal. accuracy ↑

0.7916

ISRUC subgroup I, EEG, frozen features + strict linear probe, mean ± sd over 3 pretrain seeds (±0.0081); full fine-tune 0.8107

Note: These leaderboards show results as reported by each paper. Differences in train/test splits, evaluation protocols, or preprocessing mean that numbers are not always directly comparable across entries, even within the same board. We never merge metrics or datasets.