Samsung Galaxy Watch vs Garmin: Sensors Compared

Samsung's Galaxy Watch7 and Watch Ultra offer an FDA-cleared ECG app and cuffless blood pressure estimates that need cuff calibration every 28 days; they pair only with Android. Garmin's Venu 3 and Fenix 8 offer an ECG App in eligible regions and battery measured in weeks. No study compares current Samsung and Garmin heart-rate accuracy.

Devices

ChatPPG comparison of Samsung Galaxy Watch (Watch7 / Ultra) and Garmin (Venu 3 / Forerunner 965 / Fenix 8). Product photographs, not a measurement.

Samsung Galaxy Watch7 in green: product photograph from Samsung’s gallery. Garmin fēnix 8 47 mm AMOLED, slate gray case with a black silicone band (part 010-02904-00): product photograph from Garmin.

At a glance

This page does not list head-to-head accuracy numbers, so the scoreboard shows hardware differences only.

SpecificationSamsung Galaxy Watch (Watch7 / Ultra)Garmin (Venu 3 / Forerunner 965 / Fenix 8)
BatteryDiffers425 / 300 mAh (Watch7 44 / 40 mm); Ultra up to 100 h Power SavingUp to 14 days (Venu 3); 23 days (FR965); 16 days (Fenix 8 47 mm AMOLED)
Water ResistanceDiffers5ATM + IP68 (Watch7); 10ATM + IP68 (Ultra)5 ATM (Venu 3, FR965); 10 ATM + 40 m dive (Fenix 8)
ECGDiffersECG Monitor app (FDA K201168)Venu 3 and Fenix 8: ECG App
Blood pressureDiffersEstimates; calibrate every 28 days—

Primary rows only. The study tables further down list more results from the accuracy database.

Hardware specs

SpecificationSamsung Galaxy Watch (Watch7 / Ultra)Garmin (Venu 3 / Forerunner 965 / Fenix 8)
BatteryDiffers425 / 300 mAh (Watch7 44 / 40 mm); Ultra up to 100 h Power SavingUp to 14 days (Venu 3); 23 days (FR965); 16 days (Fenix 8 47 mm AMOLED)
Water ResistanceDiffers5ATM + IP68 (Watch7); 10ATM + IP68 (Ultra)5 ATM (Venu 3, FR965); 10 ATM + 40 m dive (Fenix 8)
ECGDiffersECG Monitor app (FDA K201168)Venu 3 and Fenix 8: ECG App
Blood pressureDiffersEstimates; calibrate every 28 days—

Hardware only. Study results are not repeated in this table. Differs marks values that are not the same. An em dash means this page did not publish that figure.

Specs verified on October 17, 2026: Samsung: Galaxy Watch7 and Watch Ultra compared with previous models, Samsung Support: Galaxy Watch Ultra battery, Samsung Support: blood pressure on Galaxy Watch, Samsung Support: watch and phone compatibility, FDA 510(k) K201168: Samsung ECG Monitor App, Shcherbina et al. 2017, J Pers Med (seven wrist devices), Gillinov et al. 2017, Med Sci Sports Exerc (exercise HR vs ECG, n=50), Miller et al. 2022, Sensors (six devices vs PSG and ECG, n=53), Garmin Venu 3 owner's manual: battery information, Garmin Forerunner 965 owner's manual: battery information, Garmin Fenix 8 owner's manual: battery information, Garmin: ECG App expands to Australia and the EU (Venu 3, Fenix 8).

Pros and cons

Samsung Galaxy Watch (Watch7 / Ultra)

Pros

  • ECG Monitor app (FDA K201168)
  • Cuff-calibrated blood pressure estimates
  • Ultra: 10ATM + IP68; up to 100 h Power Saving

Cons

  • Android only
  • Blood pressure needs recalibration every 28 days; not for diagnosis
  • Older Gear S2 had the highest HR error of seven devices (Shcherbina 2017)

Garmin (Venu 3 / Forerunner 965 / Fenix 8)

Pros

  • Up to 14 days (Venu 3), 23 days (FR965), 16 days (Fenix 8 47 mm AMOLED)
  • ECG App on Venu 3 and Fenix 8 (regional availability)

Cons

  • No blood pressure estimates
  • Forerunner 245 overnight HR ICC 0.41 vs ECG (Miller 2022)

What published studies show

One table per metric. These rows come from the accuracy database and are not repeated as a second card list. From the wearable accuracy database (v1.0.0).

Heart rate at rest2 studies

Device testedResultReferenceSampleStudy
Samsung Galaxy Watch Active29.4 bpm (seated rest)Mean absolute errorHolter ECGn = 23, Rest, sedentary, low- and high-intensity phasesNissen et al. (2022)Independent
Garmin Vivoactive 4ρc = 0.9998Lin's concordance correlationECGn = 263, 30-min standardised recordingTheurl et al. (2023)Independent

Heart rate accuracy across devices →

Heart rate during exercise7 studies

Device testedResultReferenceSampleStudy
Samsung Galaxy Watch Active2squats6.1 bpm (squats)Mean absolute errorHolter ECGn = 23, Rest, sedentary, low- and high-intensity phasesNissen et al. (2022)Independent
Samsung Galaxy Watch 6Significantly higher MAE than Apple Watch SE and Verity SenseStudy finding (no single number)ECG chest strap (Polar H7/H10)n = 37, Low/moderate/high-intensity treadmillJeong et al. (2026)Independent
Samsung Gear S2Highest overall error of 7 devicesStudy finding (no single number)ECGn = 60, Sitting, walking, running, cyclingShcherbina et al. (2017)Independent
Samsung Galaxy Watch6−2.67 bpm (LoA −16.90 to 11.57)Mean bias (signed)ECG chest strap (Polar H7/H10)n = 55, Maximal incremental treadmill testInoue et al. (2026)Funding not reported
More results (2)
Device testedResultReferenceSampleStudy
Garmin Vivosmart 5Skin pigmentation did not predict error (P = 0.29)Study finding (no single number)ECG chest strap (Polar H7/H10)n = 28, Rest, cycling, recoveryMulholland et al. (2026)Independent
Garmin Fenix 52.9%–9.2% (range by intensity)Coefficient of variationECG chest strap (Polar H7/H10)n = 25, Sitting, walking, running, sprintsDüking et al. (2020)Independent

1 more result in the database. Heart rate accuracy across devices →

Overnight heart rate1 study

Device testedResultReferenceSampleStudy
Garmin Forerunner 245 MusicICC 0.41Intraclass correlationECGn = 53, Overnight, sleep laboratoryMiller et al. (2022)Other maker funded
Garmin Forerunner 245 Music5.4 bpm (absolute bias)Mean absolute errorECGn = 53, Overnight, sleep laboratoryMiller et al. (2022)Other maker funded

Heart rate accuracy across devices →

HRV (RMSSD)3 studies

Device testedResultReferenceSampleStudy
Garmin Fenix 610.52%Mean absolute percentage errorECGn = 13, Home, during sleep, 536 nightsDial et al. (2025)Independent
Garmin Fenix 60.87Lin's concordance correlationECGn = 13, Home, during sleep, 536 nightsDial et al. (2025)Independent
Garmin Forerunner 245 MusicICC 0.24Intraclass correlationECGn = 53, Overnight, sleep laboratoryMiller et al. (2022)Other maker funded
Garmin Forerunner 245 Music33.1 ms (absolute bias)Mean absolute error (absolute bias)ECGn = 53, Overnight, sleep laboratoryMiller et al. (2022)Other maker funded
More results (1)
Device testedResultReferenceSampleStudy
Garmin Vivoactive 4ρc = 0.66 (moderate)Lin's concordance correlationECGn = 263, 30-min standardised recordingTheurl et al. (2023)Independent

HRV accuracy across devices →

Sleep stages (4-stage)3 studies

Device testedResultReferenceSampleStudy
Samsung Galaxy Watch5κ = 0.42Cohen's kappaPolysomnography (PSG)n = 22, Two Korean sleep centres, in-lab PSGLee et al. (2023)Independent
Samsung Galaxy Watch564.9%Epoch-by-epoch agreementPolysomnography (PSG)n = 22, Two Korean sleep centres, in-lab PSGLee et al. (2023)Independent
Garmin Forerunner 245 Music50%Epoch-by-epoch agreementPolysomnography (PSG)n = 53, Sleep laboratory, 1 night, 9 h in bed, all devices worn togetherMiller et al. (2022)Other maker funded
Garmin Forerunner 245 Musicκ = 0.25Cohen's kappaPolysomnography (PSG)n = 53, Sleep laboratory, 1 night, 9 h in bed, all devices worn togetherMiller et al. (2022)Other maker funded
More results (1)
Device testedResultReferenceSampleStudy
Garmin Vivosmart 4κ = 0.21Cohen's kappaPolysomnography (PSG)n = 25, Sleep laboratory, 1 nightSchyvens et al. (2025)Funding not reported

Sleep accuracy across devices →

Sleep vs wake (2-stage)3 studies

Device testedResultReferenceSampleStudy
Garmin Vivosmart 4> 90% (all devices)SensitivityPolysomnography (PSG)n = 62, Sleep laboratory, 1 nightSchyvens et al. (2025)Funding not reported
Garmin Fenix 5SWorse than actigraphyStudy finding (no single number)Polysomnography (PSG)n = 34, Sleep laboratory, 3 nights incl. disrupted nightChinoy et al. (2021)Funding not reported
Garmin Vivosmart 3Worse than actigraphyStudy finding (no single number)Polysomnography (PSG)n = 34, Sleep laboratory, 3 nights incl. disrupted nightChinoy et al. (2021)Funding not reported
Garmin Forerunner 245 Music89%Epoch-by-epoch agreementPolysomnography (PSG)n = 53, Sleep laboratory, 1 night, 9 h in bed, all devices worn togetherMiller et al. (2022)Other maker funded
More results (1)
Device testedResultReferenceSampleStudy
Garmin Forerunner 245 Musicκ = 0.35Cohen's kappaPolysomnography (PSG)n = 53, Sleep laboratory, 1 night, 9 h in bed, all devices worn togetherMiller et al. (2022)Other maker funded

Sleep accuracy across devices →

Total sleep time2 studies

Device testedResultReferenceSampleStudy
Samsung Gear Sportr = 0.59Pearson correlationResearch actigraphyn = 45, Home, 7 daysAsgari Mehrabadi et al. (2020)Independent
Garmin Forerunner 945MAE 84.63 min (overestimate)Mean absolute errorPolysomnography (PSG)n = 49, 1 night PSG + MSLTBudig et al. (2022)Independent

Sleep accuracy across devices →

Blood oxygen (SpO2)8 studies

Device testedResultReferenceSampleStudy
Samsung Galaxy Watch5Met ISO RMS ≤ 4% at normoxia and SpO2 < 90%Study finding (no single number)Medical-grade pulse oximetern = 18, Induced hypoxemia (FiO2 14%, 12%, 10%), ISO 80601-2-61Walzel et al. (2023)Independent
Samsung Galaxy Watch4RMSD 1.8%Root-mean-square errorArterial blood gas (SaO2)n = 24, Hypoxia lab, SaO2 plateaus 70–100%, FDA/ISO procedureBrowne et al. (2025)Independent
Samsung Galaxy Watch4RMSE 2.54 points (overnight, vs PSG oximetry)Root-mean-square errorPSG pulse oximetryn = 51, In-lab overnight PSG, continuous SpO2Browne et al. (2024)Maker funded
Garmin Vivosmart 43.3% (rest)Root-mean-square errorMedical-grade pulse oximetern = 36, Rest, COPD outpatientsStøve et al. (2023)Funding not reported
More results (2)
Device testedResultReferenceSampleStudy
Garmin Venu 2S5.8% (RMSE 6.7%)Mean absolute errorMedical-grade pulse oximetern = 49, Spot readings, with and without chronic pulmonary diseaseJiang et al. (2023)Independent
Garmin Venu 2S6.7%Root-mean-square errorMedical-grade pulse oximetern = 49, Spot readings, with and without chronic pulmonary diseaseJiang et al. (2023)Independent

3 more results in the database. SpO2 accuracy across devices →

Atrial fibrillation detection1 study

Device testedResultReferenceSampleStudy
Samsung Galaxy Watch3smartwatch ECG app, inconclusive tracings counted85% (spec 75%)Sensitivity12-lead ECGn = 201, Tertiary cardiology service, single-lead ECG algorithmsMannhart et al. (2023)Funding not reported
Samsung Galaxy Watch3smartwatch ECG app, inconclusive tracings counted75%Specificity12-lead ECGn = 201, Tertiary cardiology service, single-lead ECG algorithmsMannhart et al. (2023)Funding not reported

AFib accuracy across devices →

VO2max estimate3 studies

Device testedResultReferenceSampleStudy
Garmin Forerunner 2457.9% / 7.2% (two runs)Mean absolute percentage errorIndirect calorimetryn = 35, Treadmill ramp testEngel et al. (2026)Funding not reported
Garmin Fenix 67.05% (CCC 0.73)Mean absolute percentage errorIndirect calorimetryn = 19, Graded exercise test and outdoor runCarrier et al. (2025)Independent
Garmin Forerunner 920XT7.3%Mean absolute percentage errorIndirect calorimetryn = 24, LabPassler et al. (2019)Independent

VO2max accuracy across devices →

Energy expenditure (calories)4 studies

Device testedResultReferenceSampleStudy
Samsung Galaxy Watch5physical activity energy expenditure, 10 min+56.76 kcalMean bias (signed)Indirect calorimetryn = 50, 10-min recumbent cycling intervalsKostrna et al. (2026)Independent
Samsung Galaxy Watch6 / Watch710.10–12.55%Mean absolute percentage errorIndirect calorimetryn = 148, 27-min intermittent treadmill runningFerreira et al. (2026)Funding not reported
Garmin Fenix 515.9%–34.5% (range by intensity)Coefficient of variationIndirect calorimetryn = 25, Sitting, walking, running, sprintsDüking et al. (2020)Independent
Garmin Forerunner 955physical activity energy expenditure, 10 min+68.61 kcalMean bias (signed)Indirect calorimetryn = 51, 10-min recumbent cycling intervalsKostrna et al. (2026)Independent
More results (1)
Device testedResultReferenceSampleStudy
Garmin Fenix 6walking32.0% walk / 21.8% runMean absolute percentage errorIndirect calorimetryn = 20, Outdoor 2-km walk (6 km/h) and run (10 km/h)Le et al. (2022)Independent

Calories accuracy across devices →

Respiratory rate1 study

Only maker-funded evidence for Samsung on this metric.

Device testedResultReferenceSampleStudy
Samsung Galaxy WatchRMSE 1.13 breaths/min (overnight average)Root-mean-square errorPolysomnography (PSG)n = 195, Overnight PSG, nasal thermocouple referenceJung et al. (2023)Maker funded

Blood pressure3 studies

Device testedResultReferenceSampleStudy
Samsung Galaxy Watch5SBP −0.34 / DBP +0.62 mmHgMean bias (signed)Validated cuff (Omron M4)n = 37, 28 days after one calibrationWalzel et al. (2026)Funding not reported
Samsung Galaxy Watch Active283% (spec 41%) for hypertensionSensitivity24-h ambulatory BP monitorn = 40, 24-h ambulatory BP monitoringFalter et al. (2022)Independent
Samsung Galaxy Watch (BP)Pre/post calibration SBP error 6.8 ± 5.6 mmHgStudy finding (no single number)Cuff used for calibrationn = 760, Real-world, 4 weeks post calibrationHan et al. (2023)Funding not reported

Blood pressure watch guide →

Skin temperature1 study

Only maker-funded evidence for Samsung on this metric.

Device testedResultReferenceSampleStudy
Samsung Galaxy Watch5r = 0.42 vs oral temperaturePearson correlationOral thermometern = 85, Nightly wrist skin temperature vs oral temperature on wakingKim et al. (2026)Maker funded

Verdict

Samsung adds blood pressure estimates on Android; Garmin offers much longer battery and works with iPhone too. Independent heart-rate evidence for both brands comes from older models.

Frequently asked questions

Which has better heart rate accuracy: Samsung Galaxy Watch or Garmin?

No study compares current models. Older-model results: Samsung Gear S2 had the highest error of seven devices (Shcherbina 2017); Garmin Forerunner 235 reached 0.81 concordance with ECG (Gillinov 2017).

Can Samsung Galaxy Watch blood pressure replace a cuff?

No. Samsung requires calibration with a cuff every 28 days and says the feature is not intended for diagnosis.