Dataset

Brno University of Technology Smartphone PPG Database (BUT PPG)

BUT PPG is a database of smartphone camera PPG recordings for evaluating PPG signal quality and estimating heart rate. It was created by the cardiology team at the Department of Biomedical Engineering, Brno University of Technology, and version 2.0.0 was published on PhysioNet on August 23, 2024 by Andrea Nemcova, Radovan Smisek, Eniko Vargova, Lucie Maršánová, Martin Vitek, Lukas Smital, Marina Filipenska, Pavlina Sikorova and Pavel Gálík. The motivation is practical. Many smartphone heart rate apps are not tested, certified or verified by medical experts. A sensible app should check signal quality before estimating heart rate and discard poor recordings, and BUT PPG was built to develop and compare algorithms for both steps. The data comprises 3,888 10-second PPG recordings from 50 subjects (25 female, 25 male) aged 19 to 76, collected between August 2020 and December 2021. Subjects either placed an index finger over the rear camera and LED of a Xiaomi Mi9 or Huawei P20 Pro smartphone, or held an ear to the front camera in the telephoning position; about half the recordings are from each site. The PPG was built from the red channel of the video by averaging each frame, then inverted, giving a sampling frequency of 30 Hz. A Bittium Faros 360 or 180 recorder captured single-lead ECG at 1,000 Hz as the heart rate reference and, in most cases, three-axis acceleration at 100 Hz. Recordings were made at rest and during deliberate disturbances: higher pressure on the camera, moving the finger or ear on the lens, walking, coughing, laughing, changing the light and talking. Each record has a binary quality label (1 means good enough for heart rate estimation, 0 means heart rate cannot be detected reliably), a reference heart rate from verified QRS positions, and single-value annotations of blood pressure, SpO2 and glycaemia. Subject information includes gender, age, height, weight, measurement spot and motion type. All data is in WFDB format with a CSV annotation file. The total uncompressed size is 203.3 MB, or an 86.7 MB ZIP, and it is open access under the Creative Commons Attribution 4.0 International license. BUT PPG is a standard public benchmark for smartphone camera PPG quality assessment, which makes it a useful contrast to wrist and fingertip clinical PPG datasets.

Recordings
3,888 10-second smartphone PPG recordings
Size
203.3 MB; CC BY 4.0
Creator

Brno University of Technology; PhysioNet version 2.0.0 (August 23, 2024), DOI 10.13026/tn53-8153

PPG

Xiaomi Mi9 and Huawei P20 Pro cameras, finger or ear, 30 Hz

Reference

single-lead ECG at 1,000 Hz, accelerometer at 100 Hz; binary quality label and reference HR

Original description

Brno University of Technology Smartphone PPG Database (BUT PPG) is a database created by the cardiology team at the Department of Biomedical Engineering, Brno University of Technology, for the purpose of evaluating PPG quality and estimation of heart rate (HR). The data comprises 3,888 10-second recordings of PPGs and associated ECG signals used for determination of reference HR. All of the signals contain QRS complex positions, most signals contain moreover accelerometric data (ACC), and single-value annotations of blood pressure, blood oxygen saturation and glycaemia. The data were collected from 50 subjects (25 female, 25 male) aged between 19 to 76 years at rest and during various types of movement. Recordings were carried out between August 2020 and December 2021. PPG data were collected by smartphones Xiaomi Mi9 and Huawei P20 Pro with sampling frequency of 30 Hz. Reference ECG signals and ACC data were recorded using a mobile recorder Bittium Faros 360 or 180 with a sampling frequency of 1,000 Hz (ECG) and 100 Hz (ACC). Each PPG signal includes annotation of quality and reference HR. PPG signal quality is indicated binary: 1 indicates good quality for HR estimation, 0 indicates signals where HR cannot be detected reliably and thus these signals are unsuitable for any analysis.

Verbatim fromPhysioNet· Licence: Creative Commons Attribution 4.0 International Public License

Brno University of Technology Smartphone PPG Database (BUT PPG): overview

The Brno University of Technology Smartphone PPG Database (BUT PPG) was built to evaluate PPG signal quality and heart-rate estimation from phone cameras. Version 2.0 on PhysioNet contains 3,888 ten-second PPG recordings with paired ECG for reference heart rate. Most records also include accelerometer data, and single-lead ECG QRS positions are provided. Licence is CC BY 4.0.

What's inside

Recordings
3,888 × 10 s PPG
Subjects
50
PPG
Smartphone camera PPG at 30 Hz
ECG reference
Faros ECG at 1000 Hz with QRS positions
Motion
Accelerometer at 100 Hz on most records
Tasks
PPG quality, heart-rate estimation
Licence
CC BY 4.0

How to access it

Host: PhysioNet

  1. Open the PhysioNet project page (DOI 10.13026/tn53-8153).
  2. Download version 2.0.0 under CC BY 4.0 (open access).
  3. Use the QRS annotations and ECG channel for reference heart rate.

Licence: CC BY 4.0

What it allows: Sharing and adaptation, including commercial, with attribution.

Caveats

  • Smartphone PPG at 30 Hz is much lower than wearable PPG; algorithms may not transfer.
  • Subject-wise splits matter: many recordings come from fewer subjects.

Similar datasets

DatasetSubjectsSignalsLicence
IEEE Signal Processing Cup 2015 (TROIKA)12ppg, accel, ecgCC BY 4.0
PPG-DaLiA15ppg, ecg, accel, skin-temp, respScientific, non-commercial use with credit to the owners
BIDMC PPG and Respiration (Pimentel 2016 / PhysioNet)53ppg, ecg, resp, spo2ODC-By 1.0
Pulse Transit Time PPG22ppg, ecg, accel, gyroODbL 1.0

Sources: PhysioNet BUT PPG · DOI · Updated 2026-10-19

Brno University of Technology Smartphone PPG Database (BUT PPG): ChatPPG research summary card

Key numbers

50
Subjects
2
Reference labels
HR, GLUCOSE
100Hz
Released sampling rate
smartphone PPG 30Hz; Faros ECG 1000Hz; accel 100Hz mostly

How it works

How Brno University of Technology Smartphone PPG Database (BUT PPG) works: Devices & body sites → Signals recorded → TasksDevices & body sites: Bittium Faros (Bittium · Chest). PPG sites: Finger, Face camera. Signals recorded: Brno University of Technology Smartphone PPG Database (BUT PPG), 50 subjects · 100Hz, signals PPG, ECG. Tasks: Glucose; Heart rate.Devices & body sitesBittium Faros: Bittium · ChestBittium FarosBittium · ChestPPG sites: Finger, Face cameraPPG sitesFinger, Face cameraSignals recordedBrno University of Technology…50 subjects · 100HzPPGECGTasksGlucoseGlucoseHeart rateHeart rate
Sampling
smartphone PPG 30Hz; Faros ECG 1000Hz; accel 100Hz mostly
Reference labels
hr, glucose

Devices· 1

Full photo credits, sources and licences are on each device page.

Leaderboard rows· 1

All leaderboards
TaskDatasetMetricValueRank
Heart rate estimationBrno University of Technology Smartphone PPG Database (BUT PPG)MAE (bpm) ↓7.86#1 / 1

Papers and models using this dataset· 14

#16 of 186 most-used datasets by published papers and models · #8 of 88 PPG · #10 of 78 ECG

Browse these 9 papers in the research explorer (filtered to Brno University of Technology Smartphone PPG Database (BUT PPG))

FAQ

How do I download BUT PPG?

From PhysioNet https://physionet.org/content/butppg/2.0.0/ under CC BY 4.0 (DOI 10.13026/tn53-8153).

How many recordings are in BUT PPG?

Version 2.0 has 3,888 ten-second smartphone PPG recordings with ECG-derived reference heart rate.

What is BUT PPG used for?

PPG signal-quality assessment and heart-rate estimation from smartphone cameras, with ECG as the reference.

What is BUT PPG?

BUT PPG is a PhysioNet database of 3,888 ten-second smartphone camera PPG recordings from 50 subjects, with ECG-based reference heart rate and a binary quality label for each record.

BUT PPG vs PPG-DaLiA?

BUT PPG uses smartphone cameras at 30 Hz on the finger or ear with labeled disturbances. PPG-DaLiA uses a wrist Empatica E4 at 64 Hz during daily life activities.

What are BUT PPG benchmark tasks?

It is meant for PPG quality classification (good vs poor) and heart rate estimation against an ECG reference, with blood pressure, SpO2 and glycaemia as extra labels.

Cite this dataset

Cite this dataset with the fields recorded here. Check it against the publisher before submitting.

Nemcova, A., Smisek, R., Vargova, E., Maršánová, L., Vitek, M., Smital, L., Filipenska, M., Sikorova, P., & Gálík, P. (2024). Brno University of Technology Smartphone PPG Database (BUT PPG) [Data set]. physionet. https://doi.org/10.13026/TN53-8153
Nemcova, Andrea, Radovan Smisek, Eniko Vargova, Lucie Maršánová, Martin Vitek, Lukas Smital, Marina Filipenska, Pavlina Sikorova, and Pavel Gálík. 2024. "Brno University of Technology Smartphone PPG Database (BUT PPG)." physionet. https://doi.org/10.13026/TN53-8153.
Nemcova, A., Smisek, R., Vargova, E., Maršánová, L., Vitek, M., Smital, L., Filipenska, M., Sikorova, P. and Gálík, P. (2024) 'Brno University of Technology Smartphone PPG Database (BUT PPG)', physionet. doi: 10.13026/TN53-8153.
Nemcova, Andrea, et al. "Brno University of Technology Smartphone PPG Database (BUT PPG)." physionet, 2024. https://doi.org/10.13026/TN53-8153.
A. Nemcova et al., "Brno University of Technology Smartphone PPG Database (BUT PPG)," physionet, 2024, doi: 10.13026/TN53-8153.
@misc{nemcova2024brno,
  title         = {{Brno University of Technology Smartphone PPG Database (BUT PPG)}},
  author        = {Nemcova, Andrea and Smisek, Radovan and Vargova, Eniko and Maršánová, Lucie and Vitek, Martin and Smital, Lukas and Filipenska, Marina and Sikorova, Pavlina and Gálík, Pavel},
  year          = {2024},
  howpublished  = {physionet},
  publisher     = {PhysioNet},
  doi           = {10.13026/TN53-8153}
}

Cite the ChatPPG record

Cite the dated snapshot 2026-10 for a fixed, reproducible version. Please also cite the original publications listed above.

APA

ChatPPG. (2026). Brno University of Technology Smartphone PPG Database (BUT PPG): dataset record (Version 2026-10) [Data set]. ChatPPG Research Hub. https://chatppg.com/research/datasets/butppg

BibTeX
@misc{chatppg_dataset_butppg,
  author       = {{ChatPPG}},
  title        = {{Brno University of Technology Smartphone PPG Database (BUT PPG): dataset record}},
  year         = {2026},
  month        = nov,
  version      = {2026-10},
  howpublished = {\url{https://chatppg.com/research/datasets/butppg}},
  note         = {ChatPPG Research Hub, Snapshot 2026-10, https://chatppg.com/research/snapshots/2026-10}
}
CITATION.cff
cff-version: 1.2.0
message: "If you use this resource, please cite it as below."
type: dataset
title: "Brno University of Technology Smartphone PPG Database (BUT PPG): dataset record"
authors:
  - name: "ChatPPG"
url: "https://chatppg.com/research/datasets/butppg"
repository-artifact: "https://chatppg.com/research/snapshots/2026-10"
version: "2026-10"
date-released: "2026-11-13"

History

  1. Record updated