Cite this dataset
MHEALTH [Data set]. (n.d.). uci-ml-repository. https://doi.org/10.24432/C5TW22
@misc{mhealthmhealth,
title = {{MHEALTH}},
howpublished = {uci-ml-repository},
doi = {10.24432/C5TW22}
}MHEALTH records body motion and vital signs from ten volunteers doing 12 physical activities. Shimmer2 sensors on the chest, right wrist and left ankle measured acceleration, rate of turn and magnetic field, and the chest sensor also recorded 2-lead ECG. It was donated to the UCI repository in 2014 to benchmark human behavior analysis from body-worn sensors.
The MHEALTH (Mobile Health) dataset is devised to benchmark techniques dealing with human behavior analysis based on multimodal body sensing.
The MHEALTH (Mobile HEALTH) dataset comprises body motion and vital signs recordings for ten volunteers of diverse profile while performing several physical activities. Sensors placed on the subject's chest, right wrist and left ankle are used to measure the motion experienced by diverse body parts, namely, acceleration, rate of turn and magnetic field orientation. The sensor positioned on the chest also provides 2-lead ECG measurements, which can be potentially used for basic heart monitoring, checking for various arrhythmias or looking at the effects of exercise on the ECG.
———————————————————————————————————————- DATASET SUMMARY: #Activities: 12 #Sensor devices: 3 #Subjects: 10 ———————————————————————————————————————-
EXPERIMENTAL SETUP The collected dataset comprises body motion and vital signs recordings for ten volunteers of diverse profile while performing 12 physical activities (Table 1). Shimmer2 [BUR10] wearable sensors were used for the recordings. The sensors were respectively placed on the subject's chest, right wrist and left ankle and attached by using elastic straps (as shown in the figure in attachment). The use of multiple sensors permits us to measure the motion experienced by diverse body parts, namely, the acceleration, the rate of turn and the magnetic field orientation, thus better capturing the body dynamics. The sensor positioned on the chest also provides 2-lead ECG measurements which are not used for the development of the recognition model but rather collected for future work purposes. This information can be used, for example, for basic heart monitoring, checking for various arrhythmias or looking at the effects of exercise on the ECG. All sensing modalities are recorded at a sampling rate of 50 Hz, which is considered sufficient for capturing human activity. Each session was recorded using a video camera. This dataset is found to generalize to common activities of the daily living, given the diversity of body parts involved in each one (e.g., frontal elevation of arms vs. knees bending), the intensity of the actions (e.g., cycling vs. sitting and relaxing) and their execution speed or dynamicity (e.g., running vs. standing still). The activities were collected in an out-of-lab environment with no constraints on the way these must be executed, with the exception that the subject should try their best when executing them.
ACTIVITY SET The activity set is listed in the following: L1: Standing still (1 min) L2: Sitting and relaxing (1 min) L3: Lying down (1 min) L4: Walking (1 min) L5: Climbing stairs (1 min) L6: Waist bends forward (20x) L7: Frontal elevation of arms (20x) L8: Knees bending (crouching) (20x) L9: Cycling (1 min) L10: Jogging (1 min) L11: Running (1 min) L12: Jump front & back (20x) NOTE: In brackets are the number of repetitions (Nx) or the duration of the exercises (min).
A complete and illustrated description (including table of activities, sensor setup, etc.) of the dataset is provided in the papers presented in the section "Citation Requests".
Verbatim fromUCI Machine Learning Repository· Licence: CC BY 4.0 (UCI default)
MHEALTH (Banos et al., 2014) records body motion and vital signs from ten volunteers doing 12 physical activities outside the lab. Shimmer2 sensors on the chest, right wrist and left ankle captured acceleration, plus rate of turn and magnetic field on the wrist and ankle units, while the chest unit also recorded 2-lead ECG. Every channel is sampled at 50 Hz and each session was video-labelled. It has no PPG, but its ECG makes it a useful motion-plus-cardiac reference.
Host: UCI Machine Learning Repository
Licence: Creative Commons Attribution 4.0 International (CC BY 4.0)
What it allows: Sharing and adaptation for any purpose, including commercial, with credit.
pip install pandasimport pandas as pd
cols = (["chest_ax", "chest_ay", "chest_az", "ecg1", "ecg2"]
+ [f"ankle_{s}{a}" for s in "agm" for a in "xyz"]
+ [f"arm_{s}{a}" for s in "agm" for a in "xyz"] + ["label"])
df = pd.concat(
[pd.read_csv(f"MHEALTHDATASET/mHealth_subject{i}.log", sep="\t", header=None, names=cols).assign(subject=i)
for i in range(1, 11)], ignore_index=True)
df = df[df.label != 0] # 0 = null class
print(df.shape, df.label.nunique(), df.subject.nunique())Run on the UCI download on 16 Oct 2026: 343,195 labelled rows, 12 activities, 10 subjects.
| Dataset | Subjects | Signals | Licence |
|---|---|---|---|
| PAMAP2 | 9 | accel, gyro, magnetometer, skin-temp, hr | CC BY 4.0 |
| USC-HAD | 14 | accel | Not stated |
| UCI Human Activity Recognition Using Smartphones (UCI-HAR) | 30 | imu | Creative Commons Attribution 4.0 International (CC BY 4.0) |
| OPPORTUNITY | 4 | accel | Creative Commons Attribution 4.0 International (CC BY 4.0) |
| WESAD | 15 | ppg, ecg, accel, skin-temp, eda, resp | Scientific, non-commercial use with credit to the owners |
Sources: MHEALTH on UCI · Banos et al. 2014 · Banos et al. 2015 · Updated 2026-10-16

Icons show the form factor: we have no openly licensed or manufacturer-cleared photo of these exact devices yet.
| Task | Dataset | Metric | Value | Rank |
|---|---|---|---|---|
| Human activity recognition (IMU) | MHEALTH | Accuracy ↑ | 95.09 | #1 / 1 |
| Human activity recognition (IMU) | MHEALTH | f1_har_unspecified ↑ | 99.58 | #1 / 4 |
| Human activity recognition (IMU) | MHEALTH | f1_har_unspecified ↑ | 99.23 | #2 / 4 |
| Human activity recognition (IMU) | MHEALTH | f1_har_unspecified ↑ | 97.33 | #3 / 4 |
| Human activity recognition (IMU) | MHEALTH | Macro-F1 ↑ | 88.62 (%) | #1 / 3 |
| Human activity recognition (IMU) | MHEALTH | Macro-F1 ↑ | 86.1 (%) | #2 / 3 |
| Human activity recognition (IMU) | MHEALTH | Macro-F1 ↑ | 84.6 ± 2.6 (%) | #3 / 3 |
| Human activity recognition (IMU) | MHEALTH | Macro-F1 ↑ | 68.6 probe / 72.4 FT (%) | #1 / 1 |
#25 of 186 most-used datasets by published papers and models · #13 of 84 IMU
Browse these 7 papers in the research explorer (filtered to MHEALTH)
10 volunteers and 12 activities, from standing still to running and jumping.
Yes. The chest Shimmer2 unit records 2-lead ECG at 50 Hz alongside chest acceleration.
50 Hz for every channel.
CC BY 4.0 on the UCI Machine Learning Repository.
MHEALTH [Data set]. (n.d.). uci-ml-repository. https://doi.org/10.24432/C5TW22
@misc{mhealthmhealth,
title = {{MHEALTH}},
howpublished = {uci-ml-repository},
doi = {10.24432/C5TW22}
}Cite the dated snapshot 2026-10 for a fixed, reproducible version. Please also cite the original publications listed above.
ChatPPG. (2026). MHEALTH: dataset record (Version 2026-10) [Data set]. ChatPPG Research Hub. https://chatppg.com/research/datasets/mhealth
@misc{chatppg_dataset_mhealth,
author = {{ChatPPG}},
title = {{MHEALTH: dataset record}},
year = {2026},
month = nov,
version = {2026-10},
howpublished = {\url{https://chatppg.com/research/datasets/mhealth}},
note = {ChatPPG Research Hub, Snapshot 2026-10, https://chatppg.com/research/snapshots/2026-10}
}cff-version: 1.2.0 message: "If you use this resource, please cite it as below." type: dataset title: "MHEALTH: dataset record" authors: - name: "ChatPPG" url: "https://chatppg.com/research/datasets/mhealth" repository-artifact: "https://chatppg.com/research/snapshots/2026-10" version: "2026-10" date-released: "2026-11-24"
Record updated