Paperdoi:10.2139/ssrn.7565250
Reliability-Evidence Fusion for Selective Heart-Rate Estimation from Wearable PPG: A Transformation-Aware Cross-Cohort Study
SSRN preprint
TL;DR
Frames PPG HR reliability as fusion of reliability evidence around a fixed HR estimate: signal-quality scores, learned heteroscedastic scale, and structured-output dispersion are fused to rank windows for retain/abstain without changing the estimate. Proves weak oracle dominance and decomposes AURC gain. Shows that for reciprocal pulse-interval→HR conversion the scale ratio is (ĥ/h)², which can cause operating-range-dependent ranking reversal — the propagated model-scale channel reversed ordering at a reference HR split of 110 bpm.
- Form factor: wrist
Abstract
Selective prediction requires reliability scores that preserve error-risk order, yet wearable photoplethysmography (PPG) pipelines provide heterogeneous evidence from signal quality, learned heteroscedastic scale, and structured-output dispersion. We formulate their combination as fusion of reliability evidence around a shared heart-rate estimate and ask when fusion improves retention–abstention ranking without changing the estimate itself. We prove weak oracle dominance and decompose fitted gain in the area under the risk–coverage curve (AURC) into oracle AURC reduction minus a relative excess-AURC term. For reciprocal pulse-interval-to-heart-rate conversion, the ratio of first-order scales evaluated at the predicted and true operating points is ( h/h)^2, identifying a mechanism capable of operating-range-dependent ranking reversal. Five fusion pipelines were evaluated by post-processing-level cross-fitting on fixed PPG-DaLiA exports (15 subjects) and locked transfer to quality-gated WESAD (13 subjects). The propagated model-scale channel reversed its ordering in a retrospective reference-heart-rate split at 110 beats/min, while the other channels remained positive in both cohorts. On PPG-DaLiA, the pipelines reduced mean AURC by 0.257–0.334 beats/min relative to the post hoc tail-risk-selected single channel, but the tail-risk gain remained uncertain. Risk-aligned variants were similar to equal-rank fusion, and tail regularization did not improve its development tail-risk point estimate. Locked transfer yielded an exploratory 0.125-beats/min tail-risk reduction conditional on the fixed source pipeline, quality gate, and target-selected comparator, although the best single channel changed across cohorts. Benefit depends on incremental information, estimation error, operating range, and cohort shift, not channel count or complexity alone.
Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://www.uspto.gov/ip-policy/copyright-policy/copyright-basics
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Devices
Keywords
Datasets used
How it works
Cite this paper
Nguyen, H. T. P., & Jeong, H. (2026). Reliability-Evidence Fusion for Selective Heart-Rate Estimation from Wearable PPG: A Transformation-Aware Cross-Cohort Study. SSRN preprint. https://doi.org/10.2139/ssrn.7565250
Nguyen, Hang Thi Phuong and Hieyong Jeong. 2026. "Reliability-Evidence Fusion for Selective Heart-Rate Estimation from Wearable PPG: A Transformation-Aware Cross-Cohort Study." SSRN preprint. https://doi.org/10.2139/ssrn.7565250.
Nguyen, H. T. P. and Jeong, H. (2026) 'Reliability-Evidence Fusion for Selective Heart-Rate Estimation from Wearable PPG: A Transformation-Aware Cross-Cohort Study', SSRN preprint. doi: 10.2139/ssrn.7565250.
Nguyen, Hang Thi Phuong, and Hieyong Jeong "Reliability-Evidence Fusion for Selective Heart-Rate Estimation from Wearable PPG: A Transformation-Aware Cross-Cohort Study." SSRN preprint, 2026. https://doi.org/10.2139/ssrn.7565250.
H. T. P. Nguyen and H. Jeong, "Reliability-Evidence Fusion for Selective Heart-Rate Estimation from Wearable PPG: A Transformation-Aware Cross-Cohort Study," SSRN preprint, 2026, doi: 10.2139/ssrn.7565250.
@misc{nguyen2026reliabilityevidence,
title = {{Reliability-Evidence Fusion for Selective Heart-Rate Estimation from Wearable PPG: A Transformation-Aware Cross-Cohort Study}},
author = {Nguyen, Hang Thi Phuong and Jeong, Hieyong},
year = {2026},
howpublished = {SSRN preprint},
doi = {10.2139/ssrn.7565250}
}Added to the ChatPPG research hub