Quality-Aware Wrist Photoplethysmography for Subject Independent Stress-State Monitoring: ECG-Referenced Validation and Selective Prediction

Oluwaseun Omotoso, Egberibo Paul Waredibamo (as listed on Zenodo)

Zenodo record· 2026
PPGIMUDOI

Summary

WESAD wrist BVP (64 Hz) + wrist ACC (32 Hz) + chest ECG (700 Hz), 15 participants, 865 60-s windows (30-s step), baseline vs stress, LOSO. Raw PRV best macro-F1 0.838; PPG+ACC best AUROC 0.956 / AUPRC 0.933; full model AUROC 0.952 with lowest Brier 0.116. Selective prediction: error 13.33% at 79.8% coverage → 7.48% at 61.9%.

Key facts

Form Factor
wrist
License
Not stated

Reported benchmarks

Mental workload / stress

WESAD · AUROC ↑

#4 of 6
0.956

LOSO 15 subj, 60-s windows, baseline vs stress; low-tier venue; selective prediction improves accepted-window F1

Updated: Oct 11, 2026