Paperdoi:10.5281/zenodo.22858828

Quality-Aware Wrist Photoplethysmography for Subject Independent Stress-State Monitoring: ECG-Referenced Validation and Selective Prediction

Venue listed2026Added Oct 11, 2026

  • OO
  • EZ

Authors: Oluwaseun Omotoso, Egberibo Paul Waredibamo (as listed on Zenodo)

Zenodo record (Text; part of ISSN 2581-7175)

Key results

All results

Results as reported by the authors; not independently reproduced. A SOTA star marks the best value among results reported under the same evaluation protocol; ties go to the earlier publication.

TL;DR

WESAD wrist BVP (64 Hz) + wrist ACC (32 Hz) + chest ECG (700 Hz), 15 participants, 865 60-s windows (30-s step), baseline vs stress, LOSO. Raw PRV best macro-F1 0.838; PPG+ACC best AUROC 0.956 / AUPRC 0.933; full model AUROC 0.952 with lowest Brier 0.116. Selective prediction: error 13.33% at 79.8% coverage → 7.48% at 61.9%.

  • Form factor: wrist

Abstract

Wearable photoplethysmography (PPG) offers scalable monitoring of short-timescale physiological stress, but motion artifact and the non-equivalence of pulse-rate variability (PRV) and electrocardiographic heart-rate variability (HRV) limit reliability. This study evaluates a quality-aware PPG machine-learning framework using the WESAD benchmark. Wrist blood-volume pulse (64 Hz), wrist accelerometry (32 Hz), and chest ECG (700 Hz) from 15 participants were segmented into 865 60-s windows with a 30-s step for baseline-versus-stress classification. Subjectindependent leave-one-subject-out (LOSO) evaluation compared raw PRV, conventionally filtered PRV, PPG+ACC, quality-aware PRV, and a full PPG+ACC+quality model. Raw PRV produced the highest mean Macro-F1 (0.8379), whereas PPG+ACC achieved the highest AUROC (0.9560) and AUPRC (0.9330). The full model achieved AUROC 0.9524, AUPRC 0.9295, and the lowest Brier score (0.1164). Selective prediction reduced error from 13.33% at 79.77% coverage to 7.48% at 61.85% coverage, while accepted-window Macro-F1 increased from 0.8346 to 0.8885. ECG-referenced analysis showed strong correlation for heart rate (r = 0.841, p = 0.0107) but weak correlation and poor agreement for RMSSD (r = 0.209; bias = 0.1669 s), demonstrating that PPG-derived PRV should not be treated as interchangeable with ECG-derived HRV. The results support uncertainty-aware wearable stress-state monitoring while identifying physiological validity and between-subject heterogeneity as key deployment constraints.

Verbatim from DataCite (opens in a new tab) · Licence: https://creativecommons.org/licenses/by/4.0/legalcode

Results on ChatPPG leaderboards · 1

All leaderboards
LeaderboardMethodResultRank
WESAD AUROCMental workload assessmentQuality-aware PPG+ACC0.956AUROC, higher is better#5 of 7

1 row is credited to this paper. Ranks apply within each leaderboard only, as reported by the source.

Tasks & signals

Tasks

Mental workload assessmentStressSignal quality

Signals

Keywords

StressWESADSQISelective PredictionPRV Vs HRVLOSO

Datasets used

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG, ACC); Form factor (wrist). Method: Method. Target: Stress; Signal quality.SetupSignals: PPG, ACCSignalsPPG, ACCForm factor: wristForm factorwristMethodMethodTargetStressStressSignal qualitySignal quality

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Omotoso, O., & Waredibamo, E. P. (2026). Quality-Aware Wrist Photoplethysmography for Subject Independent Stress-State Monitoring: ECG-Referenced Validation and Selective Prediction. Zenodo record. https://doi.org/10.5281/zenodo.22858828
Omotoso, Oluwaseun and Egberibo Paul Waredibamo. 2026. "Quality-Aware Wrist Photoplethysmography for Subject Independent Stress-State Monitoring: ECG-Referenced Validation and Selective Prediction." Zenodo record. https://doi.org/10.5281/zenodo.22858828.
Omotoso, O. and Waredibamo, E. P. (2026) 'Quality-Aware Wrist Photoplethysmography for Subject Independent Stress-State Monitoring: ECG-Referenced Validation and Selective Prediction', Zenodo record. doi: 10.5281/zenodo.22858828.
Omotoso, Oluwaseun, and Egberibo Paul Waredibamo "Quality-Aware Wrist Photoplethysmography for Subject Independent Stress-State Monitoring: ECG-Referenced Validation and Selective Prediction." Zenodo record, 2026. https://doi.org/10.5281/zenodo.22858828.
O. Omotoso and E. P. Waredibamo, "Quality-Aware Wrist Photoplethysmography for Subject Independent Stress-State Monitoring: ECG-Referenced Validation and Selective Prediction," Zenodo record, 2026, doi: 10.5281/zenodo.22858828.
@article{omotoso2026qualityaware,
  title         = {{Quality-Aware Wrist Photoplethysmography for Subject Independent Stress-State Monitoring: ECG-Referenced Validation and Selective Prediction}},
  author        = {Omotoso, Oluwaseun and Waredibamo, Egberibo Paul},
  year          = {2026},
  journal       = {Zenodo record},
  doi           = {10.5281/zenodo.22858828}
}