Paperdoi:10.21203/rs.3.rs-11204325/v1
Calibrated photoplethysmography-derived heart rate variability approximates electrocardiographic gold-standard performance for stress-state classification
Springer Science and Business Media LLC
Om Chhaya et al., "Calibrated photoplethysmography-derived heart rate variability approximates electrocardiographic gold-standard performance for stress-state classification: a proof-of-concept for scalable alcohol use disorder relapse monitoring", doi:10.21203/rs.3.rs-11204325/v1, CC BY 4.0
TL;DR
This study tested whether heart rate variability from PPG can stand in for ECG when classifying stress, as a proxy for relapse risk in alcohol use disorder. ECG-derived features gave 80% accuracy and an ROC AUC of 0.85. A simple linear calibration that maps PPG features to ECG raised the PPG AUC from 0.79 to 0.85, matching ECG.
- Result: Classical machine learning models achieved 80% accuracy with ROC AUC of 0.85 for binary stress classification using ECG-derived features.
- Result: Linear calibration mapping PPG features to ECG space improved PPG-based ROC AUC from 0.79 to 0.85, matching ECG performance.
Abstract
Heart rate variability (HRV) is a validated non-invasive marker of autonomic dysregulation associated with stress reactivity and relapse risk in alcohol use disorder (AUD). While electrocardiography (ECG) remains the gold standard for HRV assessment, its scalability in outpatient rehabilitation is limited. Consumer-grade wearables using photoplethysmography (PPG) offer a practical alternative, but systematic calibration of PPG-derived HRV against ECG standards has been lacking. We evaluated the feasibility of using calibrated PPG-derived HRV for stress-state classification as a proxy for relapse-relevant autonomic signatures. Using the WESAD public dataset (15 subjects, ECG + PPG), we extracted time-domain (RMSSD, SDNN, pNN50), frequency-domain (LF, HF, LF/HF), and nonlinear (sample entropy, DFA) HRV features. Classical machine learning models achieved 80% accuracy with ROC AUC of 0.85 for binary stress classification using ECG-derived features. Linear calibration mapping PPG features to ECG space improved PPG-based ROC AUC from 0.79 to 0.85, matching ECG performance. Deep sequence models (LSTM, CNN) did not improve over feature-based approaches in this dataset, likely due to limited sample size. We additionally collected seven-day concurrent PPG recordings from Empatica EmbracePlus (FDA-cleared) and Fitbit (consumer-grade) wearables worn by a study participant to characterize cross-device agreement in ambulatory settings. These results establish that calibrated PPG-derived HRV from consumer wearables can approximate ECG-level discriminative performance for stress-state classification, supporting the feasibility of scalable HRV-based relapse monitoring in AUD rehabilitation.
Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/
Results on ChatPPG leaderboards · 1
All leaderboards| Leaderboard | Method | Result | Rank |
|---|---|---|---|
| WESAD AUROCMental workload assessment | Calibrated photoplethysmography-derived heart… | 0.85AUROC, higher is better | #6 of 7 |
1 row is credited to this paper. Ranks apply within each leaderboard only, as reported by the source.
Tasks & signals
Tasks
Signals
Devices
Keywords
Datasets used
How it works
- Cohort
- 15 subjects
Cite this paper
Chhaya, O., & Ananth, V. (2026). Calibrated photoplethysmography-derived heart rate variability approximates electrocardiographic gold-standard performance for stress-state classification. Springer Science and Business Media LLC. https://doi.org/10.21203/rs.3.rs-11204325/v1
Chhaya, Om and Viswanath Ananth. 2026. "Calibrated photoplethysmography-derived heart rate variability approximates electrocardiographic gold-standard performance for stress-state classification." Springer Science and Business Media LLC. https://doi.org/10.21203/rs.3.rs-11204325/v1.
Chhaya, O. and Ananth, V. (2026) 'Calibrated photoplethysmography-derived heart rate variability approximates electrocardiographic gold-standard performance for stress-state classification', Springer Science and Business Media LLC. doi: 10.21203/rs.3.rs-11204325/v1.
Chhaya, Om, and Viswanath Ananth "Calibrated photoplethysmography-derived heart rate variability approximates electrocardiographic gold-standard performance for stress-state classification." Springer Science and Business Media LLC, 2026. https://doi.org/10.21203/rs.3.rs-11204325/v1.
O. Chhaya and V. Ananth, "Calibrated photoplethysmography-derived heart rate variability approximates electrocardiographic gold-standard performance for stress-state classification," Springer Science and Business Media LLC, 2026, doi: 10.21203/rs.3.rs-11204325/v1.
@article{chhaya2026calibrated,
title = {{Calibrated photoplethysmography-derived heart rate variability approximates electrocardiographic gold-standard performance for stress-state classification}},
author = {Chhaya, Om and Ananth, Viswanath},
year = {2026},
journal = {Springer Science and Business Media LLC},
doi = {10.21203/rs.3.rs-11204325/v1}
}Added to the ChatPPG research hub