Task leaderboard

Mental workload assessment

Benchmark results for mental workload assessment from physiological signals.

Last updated

Task leaderboard

Mental workload

7 reported results · Leaderboard page · Dataset details

Mental workload / stress: WESAD, Area under ROC. Reported rankings; evaluation protocols may differ.
RankMethod & evaluationArea under ROC↑ Higher is better
1Cross-Modal Correlation Fusion for End-to-End…

Cross-Modal Correlation Fusion for End-to-End ECG–PPG Stress Classification

Evaluation details

WESAD subject-independent 5-fold CV; dual ECG+PPG encoders + cross-modal correlation fusion; paper AUC-ROC 97.29%

Weights: not released

Reported as of: 2026-10-02

0.9729
2Pulse-PPG
Evaluation details · open weights

Binary stress; paper non-stress definition

Weights: open (true (MIT))

0.9687
3Thapa wrist-PPG features

Thapa wrist-PPG features (LR, all features; Stage 2 exploratory)

Evaluation details

LOSO pooled AUC, BVP 64 Hz 60 s windows, stress from 9 subjects; post hoc; interval-only 0.911–0.933; RF 0.972 transductive z-scoring (not ranked)

Weights: not released (n/a (no code))

0.965
4TEX-MEX 0.56M

TEX-MEX 0.56M (linear probe)

Evaluation details

Binary stress, subject-level 5-fold CV × 15 seeds (arXiv 2610.19557 Table 4); same-paper Pulse-PPG 0.9388 / AnyPPG 0.9520 — different protocol from Pulse-PPG paper row

Weights: not released (false (promised))

0.9630
5Quality-aware PPG+ACC

Quality-aware PPG+ACC (Zenodo 22858828)

Evaluation details

LOSO 15 subj, 60-s windows, baseline vs stress; low-tier venue; selective prediction improves accepted-window F1

0.956
6Calibrated photoplethysmography-derived heart…

Calibrated photoplethysmography-derived heart rate variability approximates electrocardiographic gold-standard performance for stress-state classification

Evaluation details

binary stress; classical ML on HRV features; PPG features linearly calibrated to ECG space (uncalibrated PPG 0.79; ECG 0.85); 15 subjects

Weights: not released

Reported as of: 2026-10-05

0.85
7PaPaGei-S

PaPaGei-S (re-eval)

Evaluation details · open weights

Under Pulse-PPG protocol

Weights: open (true (BSD-3))

0.8043

Rows are ranked only within this task × dataset × metric. Protocols can differ; read each method’s evaluation details before comparing.

Recent changes

  1. New entry: Quality-aware PPG+ACC, 0.956

    Mental workload assessment: WESAD: AUROC

From the hub's dated sync history: new results as they are added, and SOTA stars as they are awarded or move.

All reported results for this task (3 benchmarks)

Rankings apply within each dataset and metric. Open evaluation details for differences in protocols.

WESAD: accuracy

Mental workload / stress: WESAD, Accuracy. Reported rankings; evaluation protocols may differ.
RankMethod & evaluationAccuracy↑ Higher is better
1Cross-Modal Correlation Fusion for End-to-End…

Cross-Modal Correlation Fusion for End-to-End ECG–PPG Stress Classification

Evaluation details

WESAD subject-independent 5-fold CV; mean Accuracy 90.34%; Stress Recall 94.07%

Weights: not released

Reported as of: 2026-10-02

0.9034
2TF-MambaNet
Evaluation details · open weights

Binary stress, 8 s, frozen features (paper Table 2); accuracy — not comparable to AUROC rows; PaPaGei 0.80 / Chronos 0.77 / NormWear 0.77

Weights: open (true (MIT))

0.81

WESAD: AUROC

Mental workload / stress: WESAD, Area under ROC. Reported rankings; evaluation protocols may differ.
RankMethod & evaluationArea under ROC↑ Higher is better
1Cross-Modal Correlation Fusion for End-to-End…

Cross-Modal Correlation Fusion for End-to-End ECG–PPG Stress Classification

Evaluation details

WESAD subject-independent 5-fold CV; dual ECG+PPG encoders + cross-modal correlation fusion; paper AUC-ROC 97.29%

Weights: not released

Reported as of: 2026-10-02

0.9729
2Pulse-PPG
Evaluation details · open weights

Binary stress; paper non-stress definition

Weights: open (true (MIT))

0.9687
3Thapa wrist-PPG features

Thapa wrist-PPG features (LR, all features; Stage 2 exploratory)

Evaluation details

LOSO pooled AUC, BVP 64 Hz 60 s windows, stress from 9 subjects; post hoc; interval-only 0.911–0.933; RF 0.972 transductive z-scoring (not ranked)

Weights: not released (n/a (no code))

0.965
4TEX-MEX 0.56M

TEX-MEX 0.56M (linear probe)

Evaluation details

Binary stress, subject-level 5-fold CV × 15 seeds (arXiv 2610.19557 Table 4); same-paper Pulse-PPG 0.9388 / AnyPPG 0.9520 — different protocol from Pulse-PPG paper row

Weights: not released (false (promised))

0.9630
5Quality-aware PPG+ACC

Quality-aware PPG+ACC (Zenodo 22858828)

Evaluation details

LOSO 15 subj, 60-s windows, baseline vs stress; low-tier venue; selective prediction improves accepted-window F1

0.956
6Calibrated photoplethysmography-derived heart…

Calibrated photoplethysmography-derived heart rate variability approximates electrocardiographic gold-standard performance for stress-state classification

Evaluation details

binary stress; classical ML on HRV features; PPG features linearly calibrated to ECG space (uncalibrated PPG 0.79; ECG 0.85); 15 subjects

Weights: not released

Reported as of: 2026-10-05

0.85
7PaPaGei-S

PaPaGei-S (re-eval)

Evaluation details · open weights

Under Pulse-PPG protocol

Weights: open (true (BSD-3))

0.8043

WESAD: exact match (PulseLM QA)

Mental workload / stress: WESAD, Exact-match accuracy (e.g. PulseLM QA). Reported rankings; evaluation protocols may differ.
RankMethod & evaluationExact-match accuracy (e.g. PulseLM QA)↑ Higher is better
1PulseLM

PulseLM (Qwen2.5-7B + Pulse-PPG)

Evaluation details

10 s @125 Hz, subject-disjoint ~8/1/1 per source; categorical QA exact-match (arXiv 2603.03331 Table 2); stress label set appears multi-class (Blind 0.183); not comparable to binary acc/AUROC rows

0.497