Paperdoi:10.3390/s26092847
A Comparative Study of Signal Representations Methods and Deep Learning Architectures for PPG-Based Cuffless Blood Pressure Estimation
Sensors (MDPI) 26(9):2847
TL;DR
Seven 1D→2D transforms × several CNN variants on the UCI BP database. Best: CWT, errors reported as 3.80 ± 5.02 (SBP) and 1.65 ± 2.70 mmHg (DBP). Real-world check on 26 people vs an Omron cuff: R = 0.96 (SBP), 0.74 (DBP).
- Form factor: clinical_finger
Abstract
Hypertension is a major risk factor for cardiovascular disease and requires effective long-term monitoring. Photoplethysmography (PPG), acquired from wearable optical sensors, offers a convenient and non-invasive signal source for cuffless blood pressure (BP) estimation, but existing studies have mainly emphasized model architecture optimization, with limited systematic investigation of signal representation. This study systematically compares seven one-dimensional-to-two-dimensional signal transformation methods and evaluates multiple architectural variants for PPG-based cuffless BP estimation under a unified framework. Experiments were conducted using PPG and arterial BP signals from the UCI Open Blood Pressure Database. The best-performing configuration, based on continuous wavelet transform (CWT), achieved estimation errors of 3.80 ± 5.02 mmHg for systolic BP and 1.65 ± 2.70 mmHg for diastolic BP. Further real-world validation on 26 participants using an Omron cuff-based monitor as the reference showed good consistency, with correlation coefficients of R = 0.96 for SBP and R = 0.74 for DBP. The results demonstrate that appropriate signal representation, particularly CWT, plays a critical role in improving estimation accuracy and robustness, and may facilitate the development of wearable cuffless BP monitoring systems.
Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
Datasets used
How it works
Cite this paper
Zhang, H., Hu, X., Zhang, X., Chen, Z., Liang, Y., & Wang, G. (2026). A Comparative Study of Signal Representations Methods and Deep Learning Architectures for PPG-Based Cuffless Blood Pressure Estimation. Sensors, 26(9), 2847. https://doi.org/10.3390/s26092847
Zhang, Han, Xudong Hu, Xizhuang Zhang, Zhencheng Chen, Yongbo Liang, and Gang Wang. 2026. "A Comparative Study of Signal Representations Methods and Deep Learning Architectures for PPG-Based Cuffless Blood Pressure Estimation." Sensors 26 (9): 2847. https://doi.org/10.3390/s26092847.
Zhang, H., Hu, X., Zhang, X., Chen, Z., Liang, Y. and Wang, G. (2026) 'A Comparative Study of Signal Representations Methods and Deep Learning Architectures for PPG-Based Cuffless Blood Pressure Estimation', Sensors, 26(9), p. 2847. doi: 10.3390/s26092847.
Zhang, Han, et al. "A Comparative Study of Signal Representations Methods and Deep Learning Architectures for PPG-Based Cuffless Blood Pressure Estimation." Sensors, vol. 26, no. 9, 2026, p. 2847. https://doi.org/10.3390/s26092847.
H. Zhang, X. Hu, X. Zhang, Z. Chen, Y. Liang, and G. Wang, "A Comparative Study of Signal Representations Methods and Deep Learning Architectures for PPG-Based Cuffless Blood Pressure Estimation," Sensors, vol. 26, no. 9, p. 2847, 2026, doi: 10.3390/s26092847.
@article{zhang2026comparative,
title = {{A Comparative Study of Signal Representations Methods and Deep Learning Architectures for PPG-Based Cuffless Blood Pressure Estimation}},
author = {Zhang, Han and Hu, Xudong and Zhang, Xizhuang and Chen, Zhencheng and Liang, Yongbo and Wang, Gang},
year = {2026},
journal = {Sensors},
volume = {26},
number = {9},
pages = {2847},
publisher = {MDPI},
doi = {10.3390/s26092847}
}Added to the ChatPPG research hub