A Comprehensive Inference-Time Augmentation Framework in Physiological Signals: Application to PPG-Based AF Detection

Under review2026Added Sep 26, 2026

  • DF
  • RY
  • SK
  • ZC
  • XH

Authors: Davood Fattahi, Runze Yan, Saurabh Kataria, Zhaoliang Chen, Xiao Hu

arXiv preprint (cs.LG, eess.SP, q-bio.QM) · 22 pages, 11 figures, 4 tables. Under review at Physiological Measurement

TL;DR

Objective: Accurate classification of physiological signals in real-world deployments is challenged by sensor noise, motion artifacts, and distribution shifts between training and deployment data. Inference-time augmentation (ITA), which applies augmentations during inference rather than retraining, offers a simple, model-agnostic mechanism to improve robustness. However, ITA application to physiological signals has remained narrow in scope, relying on limited augmentation methods with fixed, unoptimized parameters.

  • Form factor: lab

Abstract

Objective: Accurate classification of physiological signals in real-world deployments is challenged by sensor noise, motion artifacts, and distribution shifts between training and deployment data. Inference-time augmentation (ITA), which applies augmentations during inference rather than retraining, offers a simple, model-agnostic mechanism to improve robustness. However, ITA application to physiological signals has remained narrow in scope, relying on limited augmentation methods with fixed, unoptimized parameters. This work proposes a unified ITA framework to address that gap. Approach: The framework incorporates 13 augmentation methods spanning time-domain, amplitude-domain, frequency-domain, and artifact-injection transformations, with hyperparameters optimized via Bayesian optimization. We evaluate on atrial fibrillation (AF) detection from 30-second PPG signals using GPT-PPG and ResNet across five datasets comprising more than 400 patients and ~9,800 hours of recording. Main results: Standard ITA consistently improved AUROC (up to 8.5% for GPT-PPG and 0.7% for ResNet) and AUPRC (up to 10.6% for GPT-PPG and 0.8% for ResNet). Selective ITA further reduced average FPR by up to 4.4% (GPT-PPG) and 1.3% (ResNet) on non-AF datasets. Significance: These findings establish ITA as a practical, model-agnostic approach for improving PPG-based AF classification reliability in deployment settings where retraining is not feasible, with broader applicability to physiological signal analysis.

Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Blood pressure

Signals

Keywords

cuffless-BPTTAaugmentationinference

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG); Form factor (lab). Method: Method. Target: Blood pressure.SetupSignals: PPGSignalsPPGForm factor: labForm factorlabMethodMethodTargetBlood pressureBlood pressure

Cite this paper

APA

Fattahi, D., Yan, R., Kataria, S., Chen, Z., & Hu, X. (2026). A Comprehensive Inference-Time Augmentation Framework in Physiological Signals: Application to PPG-Based AF Detection. arXiv preprint · 22 pages, 11 figures, 4 tables. Under review at Physiological Measurement. https://doi.org/10.1088/1361-6579/ae7d82

BibTeX

@misc{fattahi2026comprehensive,
  title         = {{A Comprehensive Inference-Time Augmentation Framework in Physiological Signals: Application to PPG-Based AF Detection}},
  author        = {Fattahi, Davood and Yan, Runze and Kataria, Saurabh and Chen, Zhaoliang and Hu, Xiao},
  year          = {2026},
  howpublished  = {arXiv preprint · 22 pages, 11 figures, 4 tables. Under review at Physiological Measurement},
  doi           = {10.1088/1361-6579/ae7d82},
  eprint        = {2606.10410},
  archivePrefix = {arXiv}
}

Built from the hub record. Check it against the publisher before submitting.

Added to the ChatPPG research hub