ExpertoRhythm: Morphology-Aware Learning for Waveform Reconstruction and Cuffless Blood Pressure Estimation from Single-Channel PPG
arXiv preprint; Version of Record in LNAI 16748 (AIME 2026)
Key results
All results- ExpertoRhythmTable 3 (source, opens in a new tab)
2.46
MAE (mmHg) ↓
Cuffless blood pressure · UCI cuff-less BP (942 subjects)
SBP · PPG→ABP waveform reconstruction, end-to-end
Results as reported by the authors; not independently reproduced. A SOTA star marks the best value among results reported under the same evaluation protocol; ties go to the earlier publication.
TL;DR
Attention-enhanced (CPCA) 1D U-Net reconstructs full arterial blood pressure (ABP) waveform from single-channel PPG, then derives SBP/DBP from waveform extrema. Composite morphology-aware loss: range-weighted SmoothL1 + window-range amplitude regularizer (λAR=0.6 peak). Evaluated on UCI cuff-less BP dataset (MIMIC-derived; 942 subjects; 10 s @ 125 Hz).
- Form factor: lab
- Possible data leakage: UCI (MIMIC-II) ships no patient IDs, so the subject-block holdout cannot be confirmed; DBP 1.46 near the art-line noise floor.
- Not independently confirmed: 942 subjects (UCI ships no patient IDs).
- Not independently confirmed: AAMI pass and BHS Grade A claims for SBP and DBP.
Abstract
Continuous cuffless blood pressure (BP) monitoring from photoplethysmography (PPG) has strong potential for wearable health and telemonitoring, but accurate estimation remains difficult because PPG-to-BP mapping must preserve subtle waveform morphology and pressure-range-dependent dynamics. We introduce ExpertoRhythm, an attention-enhanced 1D U-Net that reconstructs the arterial blood pressure (ABP) waveform from a single-channel PPG signal and derives systolic and diastolic BP directly from the reconstructed waveform. The central contribution is a composite morphology-aware learning objective that integrates range-weighted SmoothL1 reconstruction with a window-range regularizer to emphasize high-dynamic BP segments and reduce amplitude under/over-shoot. On the UCI cuff-less BP dataset with 942 subjects, ExpertoRhythm achieves 2.46/1.46 mmHg MAE for systolic/diastolic BP (SBP/DBP), while obtaining a 30.4% average relative error reduction over pure MSE across waveform reconstruction and BP estimation metrics. Clinical-style evaluation further demonstrates low bias and strong agreement across the BP range, including high-pressure windows up to 200 mmHg, satisfying AAMI criteria and achieving BHS Grade A. These results suggest that morphology-aware waveform reconstruction from a single PPG channel can provide an accurate and practical pathway toward continuous cuffless BP monitoring in wearable and remote-care settings.
Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)
Results on ChatPPG leaderboards · 1
All leaderboards| Leaderboard | Method | Result | Rank |
|---|---|---|---|
| uci-bp MAE (mmHg)Cuffless blood pressure estimation | ExpertoRhythmCaveat: Possible data leakage: UCI (MIMIC-II) ships no patient IDs, so the subject-block holdout cannot be confirmed; DBP 1.46 near the art-line noise floor. Not independently confirmed: 942 subjects (UCI ships no patient IDs). Not independently confirmed: AAMI pass and BHS Grade A claims for SBP and DBP. | 2.46MAE (mmHg), lower is better | #1 of 3 |
1 row is credited to this paper. Ranks apply within each leaderboard only, as reported by the source.
Tasks & signals
Tasks
Signals
Keywords
Datasets used
How it works
Cite this paper
Arjomand, A., Kent, K. B., & Krylov, G. (2026). ExpertoRhythm: Morphology-Aware Learning for Waveform Reconstruction and Cuffless Blood Pressure Estimation from Single-Channel PPG. arXiv preprint. https://doi.org/10.48550/arXiv.2609.34146
Arjomand, Amir, Kenneth B. Kent, and Georgiy Krylov. 2026. "ExpertoRhythm: Morphology-Aware Learning for Waveform Reconstruction and Cuffless Blood Pressure Estimation from Single-Channel PPG." arXiv preprint. https://doi.org/10.48550/arXiv.2609.34146.
Arjomand, A., Kent, K. B. and Krylov, G. (2026) 'ExpertoRhythm: Morphology-Aware Learning for Waveform Reconstruction and Cuffless Blood Pressure Estimation from Single-Channel PPG', arXiv preprint. doi: 10.48550/arXiv.2609.34146.
Arjomand, Amir, et al. "ExpertoRhythm: Morphology-Aware Learning for Waveform Reconstruction and Cuffless Blood Pressure Estimation from Single-Channel PPG." arXiv preprint, 2026. https://doi.org/10.48550/arXiv.2609.34146.
A. Arjomand, K. B. Kent, and G. Krylov, "ExpertoRhythm: Morphology-Aware Learning for Waveform Reconstruction and Cuffless Blood Pressure Estimation from Single-Channel PPG," arXiv preprint, 2026, doi: 10.48550/arXiv.2609.34146.
@misc{arjomand2026expertorhythm,
title = {{ExpertoRhythm: Morphology-Aware Learning for Waveform Reconstruction and Cuffless Blood Pressure Estimation from Single-Channel PPG}},
author = {Arjomand, Amir and Kent, Kenneth B. and Krylov, Georgiy},
year = {2026},
howpublished = {arXiv preprint},
doi = {10.48550/arXiv.2609.34146},
eprint = {2609.34146},
archivePrefix = {arXiv}
}Record updated
Added to the ChatPPG research hub