Paperdoi:10.1109/TBCAS.2026.3736710

FiLMamba: A FiLM-Conditioned Mamba Architecture with an Energy-Efficient FPGA Accelerator for Generalizable Cuffless Blood Pressure Estimation

Published article2026Added Oct 1, 2026

  • FH
  • JW
  • WL
  • YL
  • XZ

Authors: Fan He, Jinhong Wu, Wenxian Li, Yan Li, Xiaoyang Zeng

IEEE Transactions on Biomedical Circuits and Systems (TBCAS)

Key results

All results

Results as reported by the authors; not independently reproduced. A SOTA star marks the best value among results reported under the same evaluation protocol; ties go to the earlier publication.

TL;DR

Addresses PPG morphology–BP ambiguity (similar waveforms → different pressures across subjects → mean regression) with a selective state-space (Mamba) model conditioned via Feature-wise Linear Modulation (FiLM) on a 4-D hemodynamic state vector, plus Cross-Domain Hemodynamic Alignment (CDHA) (unlabeled BN recalibration + per-calibration-unit bias correction). Evaluated on MIMIC-BP (1,524 patients): SBP/DBP SDE 6.45 / 4.96 mmHg, >2.5× better than unconditioned baselines; claims AAMI compliance. Training-free transfer to UCI-BP: 4.29 / 3.24 mmHg SDE — abstract claims first AAMI-compliant training-free cross-dataset cuffless BP result.

  • Form factor: lab

Abstract

Cuffless blood pressure (BP) estimation from photoplethysmography (PPG) is limited by a morphology-BP ambiguity that similar waveforms map to different pressures across subjects, causing population-trained models to collapse into mean regression. We propose FiLMamba, a selective state-space model conditioned via Feature-wise Linear Modulation (FiLM) on a 4-D hemodynamic state vector, and Cross-Domain Hemodynamic Alignment (CDHA), which orthogonally decomposes residual cross-corpus shift into unlabeled batch-normalization recalibration and additive bias correction per calibration unit. On MIMIC-BP across 1,524 patients, FiLMamba achieves SBP/DBP standard deviation of error (SDE) of 6.45/4.96mmHg with >2.5× improvement over unconditioned baselines, satisfying Association for the Advancement of Medical Instrumentation (AAMI) compliance. Under training-free transfer, it further reaches 4.29/3.24mmHg on UCI-BP, the first AAMI-compliant training-free cross-dataset result in cuffless BP estimation. A dedicated FPGA accelerator specializes this stack on Zynq UltraScale+ through Heterogeneous Engine Reuse Orchestration (HERO) and Persistent Recurrent In-SRAM Mamba (PRISM), operating at 0.514W dynamic power and 150MHz with 8.23 μJ per sample, 15.3-41.1× below evaluated CPU/GPU platforms, and an energy-delay product of 0.046 J·s that is 1.87-14.8× below every general-purpose baseline.

Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher

Results on ChatPPG leaderboards · 2

All leaderboards
LeaderboardMethodResultRank
MIMIC-BP SDE (mmHg)Cuffless blood pressure estimationFiLMamba6.45SDE (mmHg), lower is better#1 of 1
uci-bp SDE (mmHg)Cuffless blood pressure estimationFiLMamba4.29SDE (mmHg), lower is better#1 of 1

2 rows are credited to this paper. Ranks apply within each leaderboard only, as reported by the source.

Tasks & signals

Signals

Keywords

Cuffless BPMambaFiLMFPGAAAMICross DatasetLab PPG

Datasets used

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG); Form factor (lab). Method: Method (State-space model). Target: Blood pressure.SetupSignals: PPGSignalsPPGForm factor: labForm factorlabMethodMethodState-space modelTargetBlood pressureBlood pressure

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

He, F., Wu, J., Li, W., Li, Y., & Zeng, X. (2026). FiLMamba: A FiLM-Conditioned Mamba Architecture with an Energy-Efficient FPGA Accelerator for Generalizable Cuffless Blood Pressure Estimation. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/TBCAS.2026.3736710
He, Fan, Jinhong Wu, Wenxian Li, Yan Li, and Xiaoyang Zeng. 2026. "FiLMamba: A FiLM-Conditioned Mamba Architecture with an Energy-Efficient FPGA Accelerator for Generalizable Cuffless Blood Pressure Estimation." IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/TBCAS.2026.3736710.
He, F., Wu, J., Li, W., Li, Y. and Zeng, X. (2026) 'FiLMamba: A FiLM-Conditioned Mamba Architecture with an Energy-Efficient FPGA Accelerator for Generalizable Cuffless Blood Pressure Estimation', IEEE Transactions on Biomedical Circuits and Systems. doi: 10.1109/TBCAS.2026.3736710.
He, Fan, et al. "FiLMamba: A FiLM-Conditioned Mamba Architecture with an Energy-Efficient FPGA Accelerator for Generalizable Cuffless Blood Pressure Estimation." IEEE Transactions on Biomedical Circuits and Systems, 2026. https://doi.org/10.1109/TBCAS.2026.3736710.
F. He, J. Wu, W. Li, Y. Li, and X. Zeng, "FiLMamba: A FiLM-Conditioned Mamba Architecture with an Energy-Efficient FPGA Accelerator for Generalizable Cuffless Blood Pressure Estimation," IEEE Transactions on Biomedical Circuits and Systems, 2026, doi: 10.1109/TBCAS.2026.3736710.
@article{he2026filmamba,
  title         = {{FiLMamba: A FiLM-Conditioned Mamba Architecture with an Energy-Efficient FPGA Accelerator for Generalizable Cuffless Blood Pressure Estimation}},
  author        = {He, Fan and Wu, Jinhong and Li, Wenxian and Li, Yan and Zeng, Xiaoyang},
  year          = {2026},
  journal       = {IEEE Transactions on Biomedical Circuits and Systems},
  doi           = {10.1109/TBCAS.2026.3736710}
}

Added to the ChatPPG research hub