PaperarXiv:2606.30156
Physically-Constrained Harmonic Separation (PCHS) for Robust HR/RR from Wrist PPG
IEEE EMBC 2026 (accepted)
TL;DR
Small Morocco-based group (UIR / UM6P / Leeds) proposes an analysis-by-synthesis framework for wrist-PPG HR and RR estimation. Instead of regressing HR/RR directly from raw PPG+accel, the model predicts a small set of physiologically meaningful parameters (fundamental frequency, 3 harmonic amplitudes, gain, baseline, plus a residual and an uncertainty term) and synthesizes the clean PPG waveform from them via an explicit sinusoidal generative model. HR comes from the recovered fundamental frequency; RR comes from slow modulations of the harmonic parameters.
- Subjects: 15
Abstract
Wrist-worn photoplethysmography (PPG) enables continuous monitoring of cardiopulmonary physiology, but reliable heart rate (HR) and respiratory rate (RR) estimation in free-living conditions remains challenging due to non-stationary motion artifacts that spectrally overlap with physiological dynamics. Existing signal-processing methods degrade under strong motion, while unconstrained deep learning approaches often lack physiological interpretability and identifiable structure. We propose a Physically-Constrained Harmonic Separation (PCHS) framework that formulates HR and RR estimation from wrist PPG as an analysis-by-synthesis problem, where accelerometer measurements condition artifact separation rather than directly regressing vital signs. A physics-guided harmonic generator decomposes the observed signal into quasi-periodic physiological components and a motion-related residual, enabling HR recovery from the fundamental frequency and RR prediction from respiratory-driven modulations of the harmonic parameters. Robust reconstruction objectives, separation constraints, and uncertainty-aware weighting stabilize the decomposition under motion. Experiments on the motion-intensive PPG-DaLiA dataset demonstrate that PCHS outperforms state-of-the-art methods while yielding interpretable signal decompositions that effectively disentangle physiological activity from motion artifacts.
Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Devices
Keywords
Datasets used
How it works
Cite this paper
Physically-Constrained Harmonic Separation (PCHS) for Robust HR/RR from Wrist PPG. (2026). IEEE EMBC 2026. https://doi.org/10.48550/arXiv.2606.30156
@inproceedings{pchsharmonicppgh2026physicallyconstraine,
title = {{Physically-Constrained Harmonic Separation (PCHS) for Robust HR/RR from Wrist PPG}},
year = {2026},
booktitle = {IEEE EMBC 2026},
doi = {10.48550/arXiv.2606.30156},
eprint = {2606.30156},
archivePrefix = {arXiv}
}