PaperarXiv:2607.18818

CITRUS: Candidate Inference, Temporal Decoding, and Reliability-Gated Reporting for Wearable Devices

PreprintFirst posted Jul 21, 2026

Authors: Yi Wang

UbiComp Companion '26 (Shanghai, Oct 11–15 2026); prior arXiv/thesis preprint 2607.18818

TL;DR

UbiComp Companion ’26 paper (ACM; companion demo MIT) building on the prior thesis/arXiv preprint — a two-layer wearable HR system for a custom finger-ring PPG platform (τ-Ring, 100 Hz IR/red + accelerometer): an estimation layer that generates ~140 candidate HR values per window from multiple DSP estimators/channels/harmonics, scores them with a small MLP, and decodes a temporally-consistent path with causal Viterbi (HMM-style dynamic programming, past-only); and a reporting layer that estimates reliability and applies a learned 3-way policy — accept the new estimate, hold the last trusted value, or reject the window outright. Directly and independently replicates the "selective reporting reduces motion-window MAE substantially" finding on an external wrist-BVP cohort: PPG-DaLiA, with proper subject-disjoint LOSO, no ring-trained weights carried over.

  • Subjects: 54

Abstract

Wearable photoplethysmography (PPG) provides continuous heart-rate measurements, but its accuracy degrades under motion. In the ring-platform benchmark, the best supervised baseline reaches 5.33 BPM mean absolute error (MAE) on the overall heart-rate task. In the motion-focused ring-only audit, a supervised LSTM baseline reaches 14.39 ± 0.47 BPM MAE on motion windows, and simple smoothing and ACC priors reduce this only to 13.00 ± 0.41 BPM. This thesis addresses motion-corrupted HR estimation through three connected stages: candidate-frequency identification, temporal decoding, and reliability-aware reporting. The study first evaluates two wearable PPG ring variants against clinical references for heart rate, respiration, SpO_2, and blood pressure in 54 participants. The proposed system then uses two layers. The estimation layer converts each window into approximately 140 frequency candidates, scores candidates using agreement among independent estimators, and applies causal Viterbi decoding with a physiological transition penalty. The reporting layer estimates reliability and applies a learned accept/hold/reject policy. Reporting only the most-confident 50% of motion windows reduces motion MAE from 10.8 to 6.2 BPM. The heart-rate estimator uses fewer than 100k parameters and runs within a microcontroller-class compute budget. Additional PPG-DaLiA experiments evaluate the same candidate-selection and temporal-decoding estimator on an independent wrist-BVP cohort.

Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Heart rate

Signals

Keywords

HRAbstentionSelective ClassificationViterbiMotion RobustnessRingDalia

Datasets used

How it works

How Method works: Setup → Method → TargetSetup: Subjects (54); Signals (ppg, accelerometer). Method: Method. Target: Heart rate.SetupSubjects: 54Subjects54Signals: ppg, accelerometerSignalsppg, accelerometerMethodMethodTargetHeart rateHeart rate

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

CITRUS: Candidate Inference, Temporal Decoding, and Reliability-Gated Reporting for Wearable Devices. (2026). UbiComp Companion '26. https://arxiv.org/abs/2607.18818
@inproceedings{citrusringhrsele2026citrus,
  title         = {{CITRUS: Candidate Inference, Temporal Decoding, and Reliability-Gated Reporting for Wearable Devices}},
  year          = {2026},
  booktitle     = {UbiComp Companion '26},
  eprint        = {2607.18818},
  archivePrefix = {arXiv}
}

Source metadata: 2026

Record updated Nov 6, 2026

Record updated