Cuffless blood pressure estimation leaderboard

PPG-BP Database (Guilin / Liang 2018): MAE (mmHg)

3 reported results for cuffless blood pressure estimation on PPG-BP Database (Guilin / Liang 2018), ranked by MAE (mmHg). Top reported: Chowdhury GPR + ReliefF…

This page ranks every result ChatPPG has recorded for cuffless blood pressure estimation on PPG-BP Database (Guilin / Liang 2018), measured by Mean absolute error (mmHg); cuffless BP (lower is better). Each number is copied from the publication cited in its row, and ranks apply only within this dataset and metric.

Cuffless blood pressure: PPG-BP Database (Guilin / Liang 2018), Mean absolute error (mmHg); cuffless BP. Reported rankings; evaluation protocols may differ.
RankMethod & evaluationMean absolute error (mmHg); cuffless BP↓ Lower is better
1Chowdhury GPR + ReliefF

Chowdhury GPR + ReliefF (Sensors 2020)

Evaluation details

Record-level random 85/15 split — NOT subject-disjoint; demographics in features; SBP fails AAMI SD

3.02
2TF-MambaNet
Evaluation details

PPG-BP (Liang 2018) 2 s segments, frozen features (paper Table 1); finger clinical PPG; DBP Chronos 8.37 better

12.89
3TEX-MEX 0.56M PPG FM

TEX-MEX 0.56M PPG FM (linear probe)

Evaluation details

Frozen LP, subject-level 5-fold CV × 15 seeds (arXiv 2610.19557 Table 4); same-paper Pulse-PPG 16.62/9.65, PaPaGei-P 15.47/9.15; finger clinical; weights promised

14.007

Rows are ranked only within this task × dataset × metric. Protocols can differ; read each method's evaluation details before comparing.

Related leaderboards

Data and submissions

Download every leaderboard as JSON or CSV. Missing a published result? Email hello@chatppg.com with the paper link and the exact table it comes from.

Cite this

Cite the page URL and the date you accessed it. Please also cite the original publications listed above.

APA

ChatPPG. (2026). Guilin / Liang 2018 MAE (mmHg) leaderboard: cuffless blood pressure estimation [Data set]. ChatPPG Research Hub. https://chatppg.com/research/leaderboards/cuffless-bp/ppgbp-guilin-mae-mmhg

BibTeX
@misc{chatppg_cuffless_bp_ppgbp_guilin_mae_mmhg,
  author       = {{ChatPPG}},
  title        = {{Guilin / Liang 2018 MAE (mmHg) leaderboard: cuffless blood pressure estimation}},
  year         = {2026},
  month        = oct,
  howpublished = {\url{https://chatppg.com/research/leaderboards/cuffless-bp/ppgbp-guilin-mae-mmhg}},
  note         = {ChatPPG Research Hub}
}
CITATION.cff
cff-version: 1.2.0
message: "If you use this resource, please cite it as below."
type: dataset
title: "Guilin / Liang 2018 MAE (mmHg) leaderboard: cuffless blood pressure estimation"
authors:
  - name: "ChatPPG"
url: "https://chatppg.com/research/leaderboards/cuffless-bp/ppgbp-guilin-mae-mmhg"
date-released: "2026-10-16"