Cuffless blood pressure estimation leaderboard
PPG-BP Database (Guilin / Liang 2018): MAE (mmHg)
3 reported results for cuffless blood pressure estimation on PPG-BP Database (Guilin / Liang 2018), ranked by MAE (mmHg). Top reported: Chowdhury GPR + ReliefF…
This page ranks every result ChatPPG has recorded for cuffless blood pressure estimation on PPG-BP Database (Guilin / Liang 2018), measured by Mean absolute error (mmHg); cuffless BP (lower is better). Each number is copied from the publication cited in its row, and ranks apply only within this dataset and metric.
| Rank | Method & evaluation | Mean absolute error (mmHg); cuffless BP↓ Lower is better |
|---|---|---|
| 1 | Chowdhury GPR + ReliefF Chowdhury GPR + ReliefF (Sensors 2020) Evaluation detailsRecord-level random 85/15 split — NOT subject-disjoint; demographics in features; SBP fails AAMI SD | 3.02 |
| 2 | TF-MambaNetEvaluation detailsPPG-BP (Liang 2018) 2 s segments, frozen features (paper Table 1); finger clinical PPG; DBP Chronos 8.37 better | 12.89 |
| 3 | TEX-MEX 0.56M PPG FM TEX-MEX 0.56M PPG FM (linear probe) Evaluation detailsFrozen LP, subject-level 5-fold CV × 15 seeds (arXiv 2610.19557 Table 4); same-paper Pulse-PPG 16.62/9.65, PaPaGei-P 15.47/9.15; finger clinical; weights promised | 14.007 |
Rows are ranked only within this task × dataset × metric. Protocols can differ; read each method's evaluation details before comparing.
About the dataset
PPG-BP Database (Guilin / Liang 2018)
- Subjects
- 219
- Signals
- ppg
- Licence
- CC0 1.0
Sources on this board
Related leaderboards
Other metrics on PPG-BP Database (Guilin / Liang 2018)
Cuffless blood pressure estimation on other datasets
- uci-bp: MAE (mmHg) (3)
- PulseDB v2.0: MAE (mmHg) (2)
- aurora-bp: MAE (mmHg) (1)
- aurora-bp-htn: accuracy (1)
- cuhk-bp-htn: accuracy (1)
- liu-wrist-9ch-array-121: MAE (mmHg) (1)
- mcbp-cold-pressor-23: MAE (mmHg) (1)
- MIMIC-BP: SDE (mmHg) (1)
- mimic-waveform-205k: MAE (mmHg) (1)
- ppg-bp: MAE (mmHg) (1)
- pulsedb-calbased: MAE (mmHg) (1)
- pulsedb-vital: MAE (mmHg) (1)
Data and submissions
Download every leaderboard as JSON or CSV. Missing a published result? Email hello@chatppg.com with the paper link and the exact table it comes from.
Cite this
Cite the page URL and the date you accessed it. Please also cite the original publications listed above.
APA
ChatPPG. (2026). Guilin / Liang 2018 MAE (mmHg) leaderboard: cuffless blood pressure estimation [Data set]. ChatPPG Research Hub. https://chatppg.com/research/leaderboards/cuffless-bp/ppgbp-guilin-mae-mmhg
BibTeX
@misc{chatppg_cuffless_bp_ppgbp_guilin_mae_mmhg,
author = {{ChatPPG}},
title = {{Guilin / Liang 2018 MAE (mmHg) leaderboard: cuffless blood pressure estimation}},
year = {2026},
month = oct,
howpublished = {\url{https://chatppg.com/research/leaderboards/cuffless-bp/ppgbp-guilin-mae-mmhg}},
note = {ChatPPG Research Hub}
}CITATION.cff
cff-version: 1.2.0 message: "If you use this resource, please cite it as below." type: dataset title: "Guilin / Liang 2018 MAE (mmHg) leaderboard: cuffless blood pressure estimation" authors: - name: "ChatPPG" url: "https://chatppg.com/research/leaderboards/cuffless-bp/ppgbp-guilin-mae-mmhg" date-released: "2026-10-16"