Learn PPG
Actigraphy Devices Compared
Research-grade actigraphy devices are accelerometers made for multi-day movement records, often with raw acceleration you can export. A 26 November 2026 subset of the Wearable Landscape database (Version 1.1, CC-BY-4.0) links validation papers, all from years through 2022, to named units. In that subset the ActiGraph GT3X+ has 77 unique studies, the original ActivPAL 52, and the GENEActiv 25. The current ActiGraph LEAP is not in the dump. A larger count is not a quality ranking, and a high risk-of-bias rate is common in this corpus.

- ActiGraph GT3X+
- ActiGraph wGT3X-BT
- ActiGraph GT9X Link
- ActiGraph LEAP
- GENEActiv
- Axivity AX3
- ActivPAL
- What is actigraphy?
What these devices are for
Actigraphy is a movement record from an accelerometer, scored into rest, activity, and an estimate of sleep versus wake. The method, and the limit that sleep stages come from polysomnography, is covered in what is actigraphy. This page compares the research-grade monitors that labs still name in papers.
Those units are built to stay on a wrist, waist, ankle, or thigh for days, and many of them store raw acceleration rather than only a proprietary activity count. A consumer watch can contain a similar sensor. The 2018 AASM evidence review (Smith et al., Journal of Clinical Sleep Medicine, doi:10.5664/jcsm.7228) said the data in hand were not enough to treat a consumer product as a stand-in for a clinical device that has a validated scoring path. This page does not add that head-to-head.
Conceptual sketch
Time above a threshold
Often 0.1 to 0.2 g
Zero crossings
Each time the signal crosses zero
Area under the curve
Digital integration across the epoch
Validation studies in the Wearable Landscape dump
Study counts, placements, settings, criterion measures, and risk-of-bias labels below come from Woll, S., and Giurgiu, M. (2026). The Wearable Landscape database – Mapping devices and their validation evidence (Version 1.1), licensed under CC-BY-4.0. ChatPPG subsetted the dump to these research-grade actigraphy models, counted each paper once per device, kept DOI, year, journal, risk-of-bias, and placement (and setting, criterion, and outcome where the dump recorded them), and left out the dump's one-line study conclusions. Device specifications on the linked records were checked against manufacturer websites on 26 November 2026 and may differ from dump fields. The ActiGraph LEAP is listed with zero studies because it does not appear in Version 1.1; the dump's studies run through 2022, and this subset's linked papers run through 2021.
A larger count is not a ranking of device quality. Risk of bias was assigned by the dataset authors with a QUADAS-2 style tool, and a high rate of "high" ratings is common in this corpus. Setting, criterion, and outcome are missing on some rows, so those tallies are only for the rows that have them.
From the dataset
Unique validation studies per research-grade device
ActiGraph GT3X+: 77 unique studies (2012–2021). Risk of bias: 4 low, 15 some concerns, 58 high.
| Device | Unique studies | Years in the subset | Risk of bias (low / some concerns / high) | Most recorded placements |
|---|---|---|---|---|
| ActiGraph GT3X+ | 77 | 2012–2021 | 4 / 15 / 58 | hip (44), wrist (25), waist (19) |
| ActivPAL (original) | 52 | 2006–2021 | 1 / 8 / 43 | upper leg (51) |
| ActiGraph GT3X | 51 | 2011–2021 | 3 / 13 / 35 | hip (25), waist (18) |
| GENEActiv | 25 | 2011–2021 | 4 / 5 / 16 | wrist (22) |
| activPAL 3 | 21 | 2012–2021 | 0 / 6 / 15 | upper leg (20) |
| ActiGraph GT9X Link | 18 | 2017–2021 | 1 / 3 / 14 | wrist (9), hip (7), waist (4) |
| ActiGraph wGT3X-BT | 17 | 2016–2021 | 1 / 3 / 13 | wrist (8), hip (7), ankle (7) |
| Axivity AX3 | 8 | 2017–2021 | 1 / 4 / 3 | upper leg (5), back torso (4), wrist (2) |
| activPAL 3 micro | 2 | 2016–2018 | 0 / 0 / 2 | upper leg (2) |
| ActiGraph LEAP | 0 | n/a | n/a | not in the dump |
Placement counts in that table are device–study–placement rows, so one paper can add more than one site. Each device record lists the papers by DOI.
Where the device was worn
Placement is part of the method, not a detail you can ignore when you compare papers. Hip and waist records are common in older ActiGraph physical-activity studies. Sleep work usually uses the wrist. The activPAL family is a thigh-worn posture monitor, which is why almost every ActivPAL and activPAL 3 row in this subset is labeled upper leg.
From the dataset
Where studies placed each device
■ hip■ upper leg■ wrist■ waist■ ankle■ back torso■ front torso■ upper arm
ActiGraph GT3X+: 106 placement rows across 77 unique studies. Most recorded: hip (44), wrist (25), waist (19).
| Placement | ActiGraph GT3X+ | ActivPAL | GENEActiv | activPAL 3 | wGT3X-BT | AX3 |
|---|---|---|---|---|---|---|
| Wrist | 25 | 0 | 22 | 0 | 8 | 2 |
| Hip | 44 | 0 | 4 | 0 | 7 | 1 |
| Waist | 19 | 0 | 0 | 0 | 6 | 0 |
| Upper leg | 5 | 51 | 1 | 20 | 1 | 5 |
| Ankle | 9 | 1 | 0 | 0 | 7 | 0 |
| Back torso | 0 | 0 | 0 | 0 | 0 | 4 |
These are row counts from the same subset, not a recommended wear site.
How to read the counts
The dump records a criterion measure for most of these papers, and a setting or named outcome for fewer of them. Among rows that have a criterion, observation and indirect calorimetry appear often for activity and energy-expenditure studies. Polysomnography appears only on a handful of sleep papers in this subset (5 for the GT3X+, 2 for the GENEActiv, 1 for the GT3X, 1 for the GT9X Link). A missing setting is a gap in the table, not evidence that the study was or was not done in free living.
If you need the scoring math, wear-time rules, or the accuracy case against polysomnography, use what is actigraphy. This page does not reprint the dump's conclusions, and it is not a buying guide or a clinical recommendation.
Model notes and current specifications
ActiGraph GT3X and GT3X+ are different models in the dump, and ChatPPG keeps them on separate records. Do not treat a GT3X paper as a GT3X+ result, or the other way around. The GT9X Link is a later ActiGraph unit with 18 studies in this subset.
The ActiGraph wGT3X-BT still has a manufacturer page at academic.ametris.com (checked 26 November 2026): 46 × 33 × 15 mm, 19 g, sample rates 30–100 Hz, ±8 g range, wear at the wrist, waist, ankle, or thigh, IPX7, about 25 days of battery life, and up to 180 days of recording in 4 GB. Those figures are from the manufacturer, not from the dump.
The current Ametris model is the ActiGraph LEAP. Ametris lists it at 24 g and 3.85 × 3.9 × 1.225 cm, with about 32 days of battery life, or about 79 days in 1 GB at the default 32 Hz, and green, red, and infrared PPG at 530, 655, and 940 nm (product page and user manual, checked 26 November 2026). The U.S. FDA 510(k) K231532 clears it for activity, sleep, and mobility measures; Ametris describes additional vital-sign outputs as investigational. Version 1.1 of the dump has no LEAP studies, which is a gap in the table, not a finding about later papers.
GENEActiv, from Activinsights, is sold as a raw, unfiltered accelerometer with light and temperature sensors, up to about two months of wear, and waterproof use. Activinsights also describes it as an FDA 510(k)-exempt Class I device (product page, checked 26 November 2026). The product page does not repeat enclosure size, so this page does not treat dump dimensions as official.
The Axivity AX3 is listed by Axivity at 23 × 32.5 × 7.6 mm and 11 g, IPX8, with about 30 days of battery life at 12.5 Hz and about 13.5 days at 100 Hz (product page, checked 26 November 2026). It is the wrist accelerometer used in UK Biobank. Raw files from studies like that are listed under raw data access.
PAL Technologies still sells an activPAL family. The current units are listed at 26 × 43 × 5 mm and 9 g (palt.com/pals, checked 26 November 2026). The 52 studies in this subset belong to the original ActivPAL, a larger 2001 professional model in the dump, and the 21 studies belong to the activPAL 3. Those counts do not transfer to the current activPAL4 or activPAL4pro.
Conceptual sketch
Actigraphy
- Limb movement from an accelerometer
- Wrist, ankle, or waist
- Can run for days
- Sleep versus wake
Polysomnography
- EEG
- Eye movements
- Muscle tone
- Sleep stages
Research on this site
These records are public datasets, models, and papers linked from this guide.
Go deeper
Frequently Asked Questions
What actigraphy devices do researchers use?
Named research-grade monitors still appear in papers: ActiGraph models (GT3X, GT3X+, GT9X Link, wGT3X-BT, and the current LEAP), the GENEActiv, the Axivity AX3, and the activPAL family. In a 26 November 2026 subset of the Wearable Landscape v1.1 dump (doi:10.5281/zenodo.23957703), the GT3X+ has 77 unique studies, the original ActivPAL 52, and the GENEActiv 25. The current LEAP is not in that dump. Counts are not a quality ranking.
What is an actigraphy watch?
People use the phrase for a wrist-worn accelerometer that records movement for days and is later scored into rest, activity, or sleep versus wake. Clinical and research units are usually screenless. A consumer watch can include a similar sensor, but the 2018 AASM evidence review (doi:10.5664/jcsm.7228) said the data in hand were not enough to treat a consumer product as a stand-in for a clinical device with a validated scoring path.
Is the ActiGraph LEAP in the Wearable Landscape validation dump?
No. Version 1.1 (doi:10.5281/zenodo.23957703) has no LEAP records. The dump's studies run through 2022, and this subset's linked papers run through 2021. That absence is not a finding about later papers. Ametris (formerly ActiGraph) lists LEAP specifications on its product page, and FDA 510(k) K231532 clears activity, sleep, and mobility measures.
Are ActiGraph GT3X and GT3X+ the same device?
No. The Wearable Landscape dump treats them as separate models, and ChatPPG keeps separate records. The subset has 51 unique GT3X studies (2011–2021) and 77 unique GT3X+ studies (2012–2021). A result from one model should not be read as a result from the other.
Do original ActivPAL studies apply to the current activPAL4?
No. The 52 studies in this subset are for the original ActivPAL, and 21 are for the activPAL 3. PAL Technologies currently lists a smaller activPAL family (26 × 43 × 5 mm, 9 g, checked 26 November 2026). Those newer counts are not in Version 1.1 of the dump.
Where can I read the validation papers?
Each device record at /research/devices lists the linked papers by DOI, with the dump's risk-of-bias label, placement, and setting when it was recorded. ChatPPG does not reprint the dump's one-line conclusions. The dataset citation is Woll and Giurgiu, 2026, doi:10.5281/zenodo.23957703, CC-BY-4.0.