Device research record

ActiGraph wGT3X-BT

Bluetooth-enabled ActiGraph research accelerometer. The Wearable Landscape v1.1 dump links 17 unique validation studies (2016–2021) to the wGT3X-BT.

Signals and sensors

From the device record. Fields the source does not state are left out.

Maker
ActiGraph
Form factor
Wrist
Signals recorded
IMU
Raw data access
Raw acceleration can be exported through ActiGraph / Ametris software, on terms set by the manufacturer and the study protocol.
Also called
wGT3X-BT, wGT3XBT

Validation studies in the Wearable Landscape dataset

The v1.1 dump links 17 unique validation studies to the ActiGraph wGT3X-BT from 2016 to 2021 (32 device–study–placement rows). Risk of bias, assigned by the dataset authors with a QUADAS-2 style tool: 1 low, 3 some concerns, 13 high. Placements recorded most often: wrist (8), ankle (7), hip (7). Setting is recorded for 4 of 17 studies (3 free living, 1 laboratory). Counts are unique studies, not a ranking of device quality. A high risk-of-bias rate is common in this corpus. Each DOI is the paper; we do not reprint the dump's one-line conclusions.

Studies rated low risk or some concerns

13 studies rated high risk of bias
YearStudyRisk of biasPlacementSetting
2021Criterion validity of the ActiGraph and activPAL in classifying posture and motion in office-based workers: A cross-section laboratory studyhighupper legn/a
2021Validation of the ActiGraph wGT3X-BT Accelerometer for Step Counts at Five Different Body Locations in Laboratory Settingshighankle, wrist, waist, upper armn/a
2020Validity of Consumer Activity Monitors and an Algorithm Using Smartphone Data for Measuring Steps during Different Activity Typeshighhipn/a
2019Accuracy of the Actigraph wGT3x-BT for step counting during inpatient spinal cord rehabilitationhighanklelaboratory
2019Hip and Wrist-Worn Accelerometer Data Analysis for Toddler Activitieshighhip, wristfree living
2019Validity of wearable activity monitors for tracking steps and estimating energy expenditure during a graded maximal treadmill testhighwaistn/a
2018Feasibility, reliability, and validity of using accelerometers to measure physical activities of patients with stroke during inpatient rehabilitationhighankle, wristfree living
2018Validating the accuracy of an activity monitor in a visually impaired older populationhighhip, ankle, wristn/a
2017Accuracy of step count measured by physical activity monitors: The effect of gait speed and anatomical placement sitehighwrist, waistn/a
2017Can energy expenditure be accurately assessed using accelerometry-based wearable motion detectors for physical activity monitoring in post-stroke patients in the subacute phase?highhip, ankle, wristn/a
2017Mobile Device Accuracy for Step Counting Across Age Groupshighwaistn/a
2016Can Commercially Available Pedometers Be Used For Physical Activity Monitoring In Patients With COPD Following Exacerbations?highhip, wristn/a
2016Comparison between Mother, ActiGraph wGT3X-BT, and a hand tally for measuring steps at various walking speeds under controlled conditionshighhipn/a

Get raw data

Tools that export or stream data from ActiGraph wGT3X-BT, checked against each project’s own site or repository. What you get depends on the route: cloud APIs mostly return summaries, while device SDKs and file readers can give finer-grained data.

All data access tools for this brand →

Browse the device database →