Device research record

ActiGraph GT3X

Earlier ActiGraph tri-axial accelerometer, kept separate from the GT3X+. The Wearable Landscape v1.1 dump links 51 unique validation studies (2011–2021) to the GT3X.

Signals and sensors

From the device record. Fields the source does not state are left out.

Maker
ActiGraph
Form factor
Wrist
Signals recorded
IMU
Also called
GT3X

Validation studies in the Wearable Landscape dataset

The v1.1 dump links 51 unique validation studies to the ActiGraph GT3X from 2011 to 2021 (56 device–study–placement rows). Risk of bias, assigned by the dataset authors with a QUADAS-2 style tool: 3 low, 13 some concerns, 35 high. Placements recorded most often: hip (25), waist (18), ankle (4). Setting is recorded for 32 of 51 studies (13 free living, 19 laboratory). Counts are unique studies, not a ranking of device quality. A high risk-of-bias rate is common in this corpus. Each DOI is the paper; we do not reprint the dump's one-line conclusions.

Studies rated low risk or some concerns

YearStudyRisk of biasPlacementSetting
2020Improving energy expenditure estimates from wearable devices: A machine learning approachsome concernswristn/a
2020Prior automatic posture and activity identification improves physical activity energy expenditure prediction from hip-worn triaxial accelerometrylowhipfree living
2018Measurement of Active and Sedentary Behavior in Context of Large Epidemiologic Studieslowhipfree living
2018Medical-Grade Physical Activity Monitoring for Measuring Step Count and Moderate-to-Vigorous Physical Activity: Validity and Reliability Studysome concernswaistn/a
2018Validation of accelerometer for measuring physical activity in free-living individualssome concernshipfree living
2018Validity of the Actigraph GT3x and influence of the sensor positioning for the assessment of active energy expenditure during four activities of daily living in stroke subjectssome concernship, ankle, wristn/a
2016Reliability and Validity of Objective Measures of Physical Activity in Youth With Cerebral Palsy Who Are Ambulatorysome concernswaistlaboratory
2014Validation and Comparison of Two Methods to Assess Human Energy Expenditure during Free-Living Activitiessome concernswaistlaboratory
2014Validity of physical activity monitors for assessing lower intensity activity in adultssome concernshipn/a
2013A Comparison of Energy Expenditure Estimation of Several Physical Activity Monitorssome concernswaistn/a
2013Energy Expenditure Estimation in Children by Activity-Specific Regressions, Random Forest and Regression Trees from Raw Accelerometer Datasome concernshiplaboratory
2013METs and Accelerometry of Walking in Older Adults: Standard versus Measured Energy Costsome concernshipn/a
2013Predicting Chinese Children and Youth's Energy Expenditure Using ActiGraph Accelerometers: A Calibration and Cross-Validation Studylowhiplaboratory
2013Validity of physical activity monitors during daily life in patients with COPDsome concernswaistfree living
2012Criterion and Concurrent Validity of the activPAL Professional Physical Activity Monitor in Adolescent Femalessome concernswaistlaboratory
2012Validity of Six Activity Monitors in Chronic Obstructive Pulmonary Disease: A Comparison with Indirect Calorimetrysome concernswaistn/a
35 studies rated high risk of bias
YearStudyRisk of biasPlacementSetting
2021The Validation of the Actigraph GT3X Step Counter in Youth Who Are Blindhighwaistlaboratory
2020Assessing Motor Function in Congenital Muscular Dystrophy Patients Using Accelerometryhighhiplaboratory
2020Validity of self-reported and objectively measured sedentary behavior in pregnancyhighfront torson/a
2019A study investigating the validity of an accelerometer in quantification of step count in adult hospital inpatients recovering from critical illnesshighankle, upper leglaboratory
2019Accuracy of 12 Wearable Devices for Estimating Physical Activity Energy Expenditure Using a Metabolic Chamber and the Doubly Labeled Water Method: Validation Studyhighwaistlaboratory
2019Validity of Activity Trackers in Estimating Energy Expenditure During High-Intensity Functional Traininghighwaistn/a
2019Validity of the accelerometer and smartphone application in estimating energy expenditure in individuals with chronic strokehighanklen/a
2019Validity of wearable actimeter computation of total energy expenditure during walking in post-stroke individualshighhipn/a
2018Accuracy of Objective Physical Activity Monitors in Measuring Steps in Older Adultshighwaistn/a
2018Establishing Raw Acceleration Thresholds to Classify Sedentary and Stationary Behaviour in Childrenhighhipfree living
2017Cross-Validation of Two Accelerometers for Assessment of Physical Activity and Sedentary Time in Preschool Childrenhighback torsofree living
2016Criterion validity of the activPAL TM and ActiGraph for assessing children's sitting and standing time in a school classroom settinghighhiplaboratory
2016Physical activity using wrist-worn accelerometers: comparison of dominant and non dominant wristhighwristfree living
2016SenseWearMini and Actigraph GT3X Accelerometer Classification of Observed Sedentary and Light-Intensity Physical Activities in a Laboratory Settinghighwaistn/a
2016Validity of Activity Monitor Step Detection Is Related to Movement Patternshighhiplaboratory
2015Concurrent validation of the Actigraph gt3x+, Polar Active accelerometer, Omron HJ-720 and Yamax Digiwalker SW-701 pedometer step counts in lab-based and free-living settingshighhiplaboratory
2015Evaluation of ActiGraph's Low-Frequency Filter in Laboratory and Free-Living Environmentshighhiplaboratory
2015Ngram time series model to predict activity type and energy cost from wrist, hip and ankle accelerometers: implications of agehighhip, ankle, wristn/a
2015Rett syndrome: establishing a novel outcome measure for walking activity in an era of clinical trials for rare disordershighwaistn/a
2015Validation of the ActiGraph GT3X and activPAL Accelerometers for the Assessment of Sedentary Behaviorhighwaistfree living
2015Validity and responsiveness of four measures of occupational sitting and standinghighhipfree living
2014Measuring reliability and validity of the ActiGraph GT3X accelerometer for children with cerebral palsy: A feasibility studyhighhiplaboratory
2014Validity of SC-StepRx pedometer-derived moderate and vigorous physical activity during treadmill walking and running in a heterogeneous sample of children and youthhighwaistlaboratory
2014Which activity monitor to use? Validity, reproducibility and user friendliness of three activity monitorshighwaistlaboratory
2013Actigraph GT3X: Validation and Determination of Physical Activity Intensity Cut Pointshighhipn/a
2013Comparing the Validity and Output of the GT1M and GT3X Accelerometer in 5- to 9-Year-Old Childrenhighwaistlaboratory
2013Comparison of ActiGraph activity monitors in persons with multiple sclerosis and controlshighhipn/a
2013Feasibility and validity of the ActiGraph GT3X accelerometer in measuring physical activity of Malawian toddlershighhipfree living
2013Validation of the GT3X ActiGraph in children and comparison with the GT1M ActiGraphhighhiplaboratory
2013Validity of actigraphs uniaxial and triaxial accelerometers for assessment of physical activity in adults in laboratory conditionshighhipn/a
2012Comparison of two ActiGraph accelerometer generations in the assessment of physical activity in free living conditionshighback torsofree living
2012Evaluation of Activity Monitors in Controlled and Free-Living Environmentshighhiplaboratory
2012Validity of Two Wearable Monitors to Estimate Breaks from Sedentary Timehighwaistfree living
2011Accuracy of Physical Activity Monitors in Pregnant Womenhighupper legn/a
2011Validation of Wearable Monitors for Assessing Sedentary Behaviorhighhipfree living