PaperarXiv:2412.09758
NormWear: Toward Foundation Model for Multivariate Wearable Sensing of Physiological Signals
IMWUT/UbiComp 2025
Luo, Yunfei et al., "Toward Foundation Model for Multivariate Wearable Sensing of Physiological Signals", arXiv:2412.09758, CC BY-NC-ND 4.0
Key results4 SOTA
All results76.060%
AUROC (%) ↑
Stress / affect · WESAD
NormWear
linear probe, full-shot
Best comparison: CLAP 72.383
98.954%
AUROC (%) ↑
Activity recognition · UCI-HAR
NormWear
linear probe, full-shot
Best comparison: TF-C 96.892
99.140%
AUROC (%) ↑
ECG diagnosis · ECG-Abnormal
NormWear
linear probe, full-shot
Best comparison: Chronos 98.585
84.381%
AUROC (%) ↑
Multi-task benchmark · NormWear 18-task benchmark (macro avg.)
NormWear
linear probe, full-shot
Best comparison: TF-C 81.230
Results as reported by the authors; not independently reproduced. A SOTA star marks the best value among results reported under the same evaluation protocol; ties go to the earlier publication.
Embed this badge (4 badges for READMEs and project pages)
- Markdown
[](https://chatppg.com/research/models/normwear#key-results)HTML<a href="https://chatppg.com/research/models/normwear#key-results"><img src="https://chatppg.com/research/badges/normwear--stress-wesad-auroc-pct.svg" alt="SOTA on ChatPPG: Stress / affect · WESAD" height="20"></a> - Markdown
[](https://chatppg.com/research/models/normwear#key-results)HTML<a href="https://chatppg.com/research/models/normwear#key-results"><img src="https://chatppg.com/research/badges/normwear--har-uci-har-auroc-pct.svg" alt="SOTA on ChatPPG: Activity recognition · UCI-HAR" height="20"></a> - Markdown
[](https://chatppg.com/research/models/normwear#key-results)HTML<a href="https://chatppg.com/research/models/normwear#key-results"><img src="https://chatppg.com/research/badges/normwear--ecg-diagnosis-ecg-abnormal-auroc-pct.svg" alt="SOTA on ChatPPG: ECG diagnosis · ECG-Abnormal" height="20"></a> - Markdown
[](https://chatppg.com/research/models/normwear#key-results)HTML<a href="https://chatppg.com/research/models/normwear#key-results"><img src="https://chatppg.com/research/badges/normwear--multi-task-normwear-benchmark-auroc-pct.svg" alt="SOTA on ChatPPG: Multi-task benchmark · NormWear 18-task benchmark (macro avg.)" height="20"></a>
TL;DR
NormWear is a foundation model for multivariate wearable sensing that works across different sensor setups. A channel-aware attention mechanism with a shared [CLS] token captures patterns within and between sensors, and it was pretrained on public PPG, ECG, EEG, GSR and IMU data. Across 11 public datasets and 18 applications in mental health, body state, vital signs and disease risk, it beat competitive baselines in zero-shot, partial-shot and full-shot settings.
- Architecture: channel-aware attention with shared [CLS] token
- Evaluation: 11 datasets, 18 applications
Abstract
Time-series foundation models excel at tasks like forecasting across diverse data types by leveraging informative waveform representations. Wearable sensing data, however, pose unique challenges due to their variability in patterns and frequency bands, especially for healthcare-related outcomes. The main obstacle lies in crafting generalizable representations that adapt efficiently across heterogeneous sensing configurations and applications. To address this, we propose NormWear, the first multi-modal and ubiquitous foundation model designed to extract generalized and informative representations from wearable sensing data. Specifically, we design a channel-aware attention mechanism with a shared special liaison [CLS] token to detect signal patterns in both intra-sensor and inter-sensors. This helps the model to extract more meaningful information considering both time series themselves and the relationships between input sensors. This helps the model to be widely compatible with various sensors settings. NormWear is pretrained on a diverse set of physiological signals, including PPG, ECG, EEG, GSR, and IMU, from various public datasets. Our model shows exceptional generalizability across 11 public wearable sensing datasets, spanning 18 applications in mental health, body state inference, vital sign estimation, and disease risk evaluation. It consistently outperforms competitive baselines under zero-shot, partial-shot, and full-shot settings, indicating broad applicability in real-world health applications.
Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Signals
Keywords
Models
How it works
Cite this paper
NormWear: Toward Foundation Model for Multivariate Wearable Sensing of Physiological Signals. (2024). IMWUT/UbiComp 2025. https://arxiv.org/abs/2412.09758
@inproceedings{normwear2024normwear,
title = {{NormWear: Toward Foundation Model for Multivariate Wearable Sensing of Physiological Signals}},
year = {2024},
booktitle = {IMWUT/UbiComp 2025},
eprint = {2412.09758},
archivePrefix = {arXiv}
}Record updated