Foundation model

NormWear

From “NormWear: Toward Foundation Model for Multivariate Wearable Sensing of Physiological Signals”
Parameters
135.3M
Year
2024
Form factor
Multivariate channel agnostic
Luo, Yunfei et al., "Toward Foundation Model for Multivariate Wearable Sensing of Physiological Signals", arXiv:2412.09758, CC BY-NC-ND 4.0
Venue listedFirst posted: Dec 12, 2024Added to atlas: Sep 26, 2026Source

Activity counts measure attention, not model quality. Missing counts are unknown. Publication status follows the linked source; a listed venue alone does not confirm peer review.

NormWear is a multimodal foundation model for wearable sensing, introduced by Yunfei Luo, Yuliang Chen, Asif Salekin and Tauhidur Rahman in "Toward Foundation Model for Multivariate Wearable Sensing of Physiological Signals". The paper first appeared on arXiv in December 2024 and was later published in ACM Transactions on Computing for Healthcare (volume 7, issue 3, 2026). General time-series foundation models do well at forecasting, but wearable signals vary widely in their patterns and frequency bands, and every study seems to use a different set of sensors. NormWear tries to handle that heterogeneity directly. Each input channel is processed on its own, and a channel-aware attention mechanism with a shared liaison [CLS] token lets the model look for patterns within one sensor and across sensors. Because channels are handled independently, the model can be pre-trained on datasets with different numbers or types of sensors and then fine-tuned on a task with yet another configuration. Pre-training used public datasets covering PPG, ECG, EEG, GSR, PCG and IMU data. The paper reports 9 public datasets used only for pre-training, giving about 230,962 multivariate segments and 4,294 hours of signal. Heuristic augmentation expanded that to 2.5 million segments, or 14,943 hours of sensor signal series. The authors evaluated NormWear on 11 public wearable sensing datasets spanning 18 applications in mental health, body state inference, vital sign estimation and disease risk evaluation. It outperformed competitive baselines in zero-shot, partial-shot and full-shot settings. Weights are public. The Hugging Face repository mosaic-laboratory/normwear (Apache-2.0) hosts the checkpoint with loading code, and a checkpoint is also attached to a GitHub release. The model card shows how to extract embeddings and fine-tune on a downstream dataset. A follow-up model, NormWear-2, is also in the hub. For PPG-only work, PaPaGei and Pulse-PPG are narrower alternatives; NormWear is the better fit when one model has to read several sensor types together.

Signals
PPG, ECG, IMU, EDA, EEG
Modalities in pre-training
PPG, ECG, EEG, GSR, PCG, IMU
Weights
Hugging Face mosaic-laboratory/normwear (Apache-2.0)
Paper

Toward Foundation Model for Multivariate Wearable Sensing of Physiological Signals (Luo, Chen, Salekin, Rahman)

Published

ACM Transactions on Computing for Healthcare 7(3), 2026; arXiv 2412.09758

Pre-training

9 public datasets, about 230,962 segments (4,294 hours), augmented to 2.5 million segments (14,943 hours)

Architecture

per-channel processing with channel-aware attention and a shared liaison [CLS] token

Evaluation

11 public datasets, 18 applications, zero-shot, partial-shot and full-shot

Key results4 SOTA

All results

Results as reported by the authors; not independently reproduced. A SOTA star marks the best value among results reported under the same evaluation protocol; ties go to the earlier publication.

Embed this badge (4 badges for READMEs and project pages)
  • SOTA on ChatPPG: Stress / affect · WESAD
    Markdown
    [![SOTA on ChatPPG: Stress / affect · WESAD](https://chatppg.com/research/badges/normwear--stress-wesad-auroc-pct.svg)](https://chatppg.com/research/models/normwear#key-results)
    HTML
    <a href="https://chatppg.com/research/models/normwear#key-results"><img src="https://chatppg.com/research/badges/normwear--stress-wesad-auroc-pct.svg" alt="SOTA on ChatPPG: Stress / affect · WESAD" height="20"></a>
  • SOTA on ChatPPG: Activity recognition · UCI-HAR
    Markdown
    [![SOTA on ChatPPG: Activity recognition · UCI-HAR](https://chatppg.com/research/badges/normwear--har-uci-har-auroc-pct.svg)](https://chatppg.com/research/models/normwear#key-results)
    HTML
    <a href="https://chatppg.com/research/models/normwear#key-results"><img src="https://chatppg.com/research/badges/normwear--har-uci-har-auroc-pct.svg" alt="SOTA on ChatPPG: Activity recognition · UCI-HAR" height="20"></a>
  • SOTA on ChatPPG: ECG diagnosis · ECG-Abnormal
    Markdown
    [![SOTA on ChatPPG: ECG diagnosis · ECG-Abnormal](https://chatppg.com/research/badges/normwear--ecg-diagnosis-ecg-abnormal-auroc-pct.svg)](https://chatppg.com/research/models/normwear#key-results)
    HTML
    <a href="https://chatppg.com/research/models/normwear#key-results"><img src="https://chatppg.com/research/badges/normwear--ecg-diagnosis-ecg-abnormal-auroc-pct.svg" alt="SOTA on ChatPPG: ECG diagnosis · ECG-Abnormal" height="20"></a>
  • SOTA on ChatPPG: Multi-task benchmark · NormWear 18-task benchmark (macro avg.)
    Markdown
    [![SOTA on ChatPPG: Multi-task benchmark · NormWear 18-task benchmark (macro avg.)](https://chatppg.com/research/badges/normwear--multi-task-normwear-benchmark-auroc-pct.svg)](https://chatppg.com/research/models/normwear#key-results)
    HTML
    <a href="https://chatppg.com/research/models/normwear#key-results"><img src="https://chatppg.com/research/badges/normwear--multi-task-normwear-benchmark-auroc-pct.svg" alt="SOTA on ChatPPG: Multi-task benchmark · NormWear 18-task benchmark (macro avg.)" height="20"></a>
At a glance
Type
Foundation model
Modalities
PPGECGIMUEDAEEG
Parameters
135.3M
Architecture
Shared transformer backbone, channel-independent streams over scalogram (ViT-style) patches
Venue
IMWUT/UbiComp 2025
Year
2024
DOI
Not reported
Code
Open
Caveats
Not reported
Datasets
Not reported
Added
Sep 26, 2026
Updated
Oct 18, 2026

Abstract

Time-series foundation models excel at tasks like forecasting across diverse data types by leveraging informative waveform representations. Wearable sensing data, however, pose unique challenges due to their variability in patterns and frequency bands, especially for healthcare-related outcomes. The main obstacle lies in crafting generalizable representations that adapt efficiently across heterogeneous sensing configurations and applications. To address this, we propose NormWear, the first multi-modal and ubiquitous foundation model designed to extract generalized and informative representations from wearable sensing data. Specifically, we design a channel-aware attention mechanism with a shared special liaison [CLS] token to detect signal patterns in both intra-sensor and inter-sensors. This helps the model to extract more meaningful information considering both time series themselves and the relationships between input sensors. This helps the model to be widely compatible with various sensors settings. NormWear is pretrained on a diverse set of physiological signals, including PPG, ECG, EEG, GSR, and IMU, from various public datasets. Our model shows exceptional generalizability across 11 public wearable sensing datasets, spanning 18 applications in mental health, body state inference, vital sign estimation, and disease risk evaluation. It consistently outperforms competitive baselines under zero-shot, partial-shot, and full-shot settings, indicating broad applicability in real-world health applications.

Verbatim fromarXiv· arXiv metadata (abstracts are released under CC0)

How it works

How NormWear works: Input signals → Foundation model → Downstream tasksInput signals: PPG (Photoplethysmogram); ECG (Electrocardiogram); IMU (Accelerometer, 3-axis); EDA (Electrodermal activity). Foundation model: NormWear, 135.3M parameters (Transformer · Masked reconstruction).Input signalsPPG: PhotoplethysmogramPPGPhotoplethysmogramECG: ElectrocardiogramECGElectrocardiogramIMU: Accelerometer, 3-axisxyzIMUAccelerometer, 3-axisEDA: Electrodermal activityEDAElectrodermal activityFoundation model×NNormWear135.3M parametersTransformer · Masked reconstruction
Architecture
Shared transformer backbone, channel-independent streams over scalogram (ViT-style) patches
Inputs
PPG, ECG, IMU, EDA, EEG
Approach
multimodal · MAE · UbiComp · channel agnostic

Datasets used

No public datasets linked yet.

Papers· 3

Authors· 4

FAQ

What is NormWear?

NormWear is a multimodal foundation model for wearable physiological signals (PPG, ECG, EEG, GSR, PCG and IMU) from Luo, Chen, Salekin and Rahman, published in ACM Transactions on Computing for Healthcare in 2026.

How do I download NormWear?

The checkpoint is on Hugging Face at https://huggingface.co/mosaic-laboratory/normwear under Apache-2.0, with a copy on the project's GitHub release page.

NormWear vs PaPaGei?

PaPaGei is a PPG-only model pre-trained on more than 57,000 hours of PPG. NormWear accepts several sensor types at once and was pre-trained on 2.5 million augmented multivariate segments, so it suits tasks that combine PPG with ECG, EEG, GSR or motion data.

What are NormWear's benchmark results?

Across 11 public wearable datasets and 18 applications, the paper reports that NormWear consistently outperformed competitive baselines in zero-shot, partial-shot and full-shot settings.

Cite this model

Cite the publication recorded for this model. Check it against the publisher before submitting.

Luo, Y., Chen, Y., Salekin, A., & Rahman, T. (2026). Toward Foundation Model for Multivariate Wearable Sensing of Physiological Signals. ACM Transactions on Computing for Healthcare, 7(3), 1–43. https://doi.org/10.1145/3803808
Luo, Yunfei, Yuliang Chen, Asif Salekin, and Tauhidur Rahman. 2026. "Toward Foundation Model for Multivariate Wearable Sensing of Physiological Signals." ACM Transactions on Computing for Healthcare 7 (3): 1–43. https://doi.org/10.1145/3803808.
Luo, Y., Chen, Y., Salekin, A. and Rahman, T. (2026) 'Toward Foundation Model for Multivariate Wearable Sensing of Physiological Signals', ACM Transactions on Computing for Healthcare, 7(3), pp. 1–43. doi: 10.1145/3803808.
Luo, Yunfei, et al. "Toward Foundation Model for Multivariate Wearable Sensing of Physiological Signals." ACM Transactions on Computing for Healthcare, vol. 7, no. 3, 2026, pp. 1–43. https://doi.org/10.1145/3803808.
Y. Luo, Y. Chen, A. Salekin, and T. Rahman, "Toward Foundation Model for Multivariate Wearable Sensing of Physiological Signals," ACM Transactions on Computing for Healthcare, vol. 7, no. 3, pp. 1–43, 2026, doi: 10.1145/3803808.
@article{luo2026toward,
  title         = {{Toward Foundation Model for Multivariate Wearable Sensing of Physiological Signals}},
  author        = {Luo, Yunfei and Chen, Yuliang and Salekin, Asif and Rahman, Tauhidur},
  year          = {2026},
  journal       = {ACM Transactions on Computing for Healthcare},
  volume        = {7},
  number        = {3},
  pages         = {1--43},
  publisher     = {Association for Computing Machinery (ACM)},
  doi           = {10.1145/3803808},
  eprint        = {2412.09758},
  archivePrefix = {arXiv}
}

Source metadata: Association for Computing Machinery (ACM) (2026) · DOI: 10.1145/3803808

Last verified Oct 11, 2026

History

  1. Record updated

  2. Added to the ChatPPG research hub