PaperarXiv:2606.11125
DMT: Demographic Conditioning, Morphology-Enhanced Transformer for Cuffless Blood Pressure Estimation from PPG Signals
arXiv preprint (eess.SP, cs.LG)
TL;DR
Blood pressure (BP) is a key marker for cardiovascular risk assessment and therapeutic decision-making, and Photoplethysmography (PPG) enables low-cost, wearable-friendly cuffless BP estimation. However, even with recent progress, many PPG-based models are trained with BP regression alone and may rely on amplitude-dominated shortcuts. In addition, demographic covariates that systematically modulate vascular compliance are often incorporated only via late fusion, limiting subject-specific representation learning.
- Form factor: lab
Abstract
Blood pressure (BP) is a key marker for cardiovascular risk assessment and therapeutic decision-making, and Photoplethysmography (PPG) enables low-cost, wearable-friendly cuffless BP estimation. However, even with recent progress, many PPG-based models are trained with BP regression alone and may rely on amplitude-dominated shortcuts. In addition, demographic covariates that systematically modulate vascular compliance are often incorporated only via late fusion, limiting subject-specific representation learning. We propose a Transformer-based network for cuffless BP estimation from PPG signal, leveraging self-attention to capture long-range dependencies across multiple cardiac cycles. To account for subject-specific vascular differences, the model is conditioned on demographics via FiLM-style feature modulation applied through the attention and feed-forward sublayers of Transformer blocks. In addition, we add an auxiliary morphology head to guide the model to attend to BP-relevant waveform morphology associated with arterial stiffness and wave reflection. Under calibration-based evaluation protocols on the large-scale PulseDB dataset, the proposed method achieves MAE of 4.56 mmHg for systolic BP and 2.62 mmHg for diastolic BP, reducing errors by 47% and 50% compared with prior demographic-enhanced PPG baselines. The resulting lightweight, single-sensor model supports scalable and clinically grounded cuffless BP estimation in calibration-enabled deployment settings.
Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
How it works
Cite this paper
APA
Shen, Y., Mathew, N., Rahimi, M., Dhakal, D., Zouridakis, G., Fu, X., et al. (2026). DMT: Demographic Conditioning, Morphology-Enhanced Transformer for Cuffless Blood Pressure Estimation from PPG Signals. arXiv preprint. https://doi.org/10.48550/arXiv.2606.11125
BibTeX
@misc{shen2026dmt,
title = {{DMT: Demographic Conditioning, Morphology-Enhanced Transformer for Cuffless Blood Pressure Estimation from PPG Signals}},
author = {Shen, Yidan and Mathew, Neville and Rahimi, Maham and Dhakal, Deependra and Zouridakis, George and Fu, Xin and others},
year = {2026},
howpublished = {arXiv preprint},
doi = {10.48550/arXiv.2606.11125},
eprint = {2606.11125},
archivePrefix = {arXiv}
}Built from the hub record. Check it against the publisher before submitting.