Cuffless Photoplethysmogram Based Beat-Beat AI Powered Continuous Blood Pressure Estimation Towards Precision Medicine
Activity counts measure attention, not model quality. Missing counts are unknown. Publication status follows the linked source; a listed venue alone does not confirm peer review.
PPG-BP (Guilin, 219 subjects): top-5 features from each of five domains (time, frequency, entropy, recurrence, statistical) via SelectKBest; Huber / TheilSen / SVR / RANSAC / linear regressors. Reported SBP MAE 0.208 (R² 0.996), DBP MAE 0.173 (R² 0.996).
- Venue: IEEE eIT 2026
- Signals: PPG
- Form factor: finger
Abstract
Continuous blood pressure (BP) monitoring is crucial for cardiovascular management, but traditional cuff-based systems are limited in practicality and real-time usability. This study presents an AI-driven approach utilizing photoplethysmography (PPG) signals from 219 subjects in the PPG-BP Dataset. From each subject's PPG waveform, features were extracted across five signal domains: time, frequency, entropy, recurrence, and statistical. Using SelectKBest for domain-specific feature selection, the top 5 features from each domain were identified and combined to form a unified feature set. Multiple regression models - including Huber, TheilSen, SVR, RANSAC, and Linear Regression - were trained to predict systolic (SBP) and diastolic (DBP) blood pressure. The best-performing models using the combined feature set were the Huber Regressor for $S B P(M A E=0. 2 0 7 9, R^2=0. 9 9 5 9) and the TheilSen Regressor for DBP (MAE .=0. 1 7 3 0, R^2=0. 9 9 6 4)$, significantly outperforming other methods. This domain-wise hybrid modeling approach demonstrates strong potential for accurate, interpretable, and non-invasive BP estimation, enabling real-time monitoring through wearable AI-based systems towards precision medicine.
Verbatim fromSemantic Scholar· Abstract via Semantic Scholar; © the authors/publisher

Key results
How it works
Datasets used· 1
Cite
@article{eitbeatbeatppgbpppgbpfea2026,
title = {{Cuffless Photoplethysmogram Based Beat-Beat AI Powered Continuous Blood Pressure Estimation Towards Precision Medicine}},
author = {Mohammed Naveed Shariff and Jieun Lee and Saurabh A. Sujanyal and Surbhi Dadwal and Shuvashis Dey and Dipankar Mitra and Gayathri Yerrapragada and Muhammed Asil Nechooli (+ others; Mayo Clinic affiliation listed)},
year = {2026},
journal = {IEEE eIT 2026},
doi = {10.1109/eIT68936.2026.11670374}
}History
Added to the ChatPPG research hub
More on ChatPPG
- LIMA-Mamba: A lightweight and distribution-robust Mamba network for PPG-based biometrics
From the title only, it is a Mamba (selective state-space) network for PPG-based biometric recogniti
- A Comparative Study of Signal Representations Methods and Deep Learning Architectures for PPG-Based Cuffless Blood Pressure Estimation
Seven 1D→2D transforms × several CNN variants on the UCI BP database. Best: CWT, errors reported as
- Accurate Cuffless Blood Pressure Estimation Using Conformer-Based PPG-to-ABP Waveform Reconstruction Framework
Single-channel PPG → Conformer → ABP waveform → SBP/DBP. Validated on MIMIC-BP (BHS grade A and AAMI