Activity counts measure attention, not model quality. Missing counts are unknown. Publication status follows the linked source; a listed venue alone does not confirm peer review.

PPG-BP (Guilin, 219 subjects): top-5 features from each of five domains (time, frequency, entropy, recurrence, statistical) via SelectKBest; Huber / TheilSen / SVR / RANSAC / linear regressors. Reported SBP MAE 0.208 (R² 0.996), DBP MAE 0.173 (R² 0.996).

  • Venue: IEEE eIT 2026
  • Signals: PPG
  • Form factor: finger
At a glance
Venue
IEEE eIT 2026
Published
2026
arXiv
Not reported
PMID
Not reported
Licence
Not reported
Signals
PPG
Form factor
Finger
Subjects
Not reported
Code
Not reported
Added
Oct 11, 2026

Abstract

Continuous blood pressure (BP) monitoring is crucial for cardiovascular management, but traditional cuff-based systems are limited in practicality and real-time usability. This study presents an AI-driven approach utilizing photoplethysmography (PPG) signals from 219 subjects in the PPG-BP Dataset. From each subject's PPG waveform, features were extracted across five signal domains: time, frequency, entropy, recurrence, and statistical. Using SelectKBest for domain-specific feature selection, the top 5 features from each domain were identified and combined to form a unified feature set. Multiple regression models - including Huber, TheilSen, SVR, RANSAC, and Linear Regression - were trained to predict systolic (SBP) and diastolic (DBP) blood pressure. The best-performing models using the combined feature set were the Huber Regressor for $S B P(M A E=0. 2 0 7 9, R^2=0. 9 9 5 9) and the TheilSen Regressor for DBP (MAE .=0. 1 7 3 0, R^2=0. 9 9 6 4)$, significantly outperforming other methods. This domain-wise hybrid modeling approach demonstrates strong potential for accurate, interpretable, and non-invasive BP estimation, enabling real-time monitoring through wearable AI-based systems towards precision medicine.

Verbatim fromSemantic Scholar· Abstract via Semantic Scholar; © the authors/publisher

Cuffless Photoplethysmogram Based Beat-Beat AI Powered Continuous Blood Pressure Estimation Towards Precision Medicine: ChatPPG research summary card

Key results

0.208
MAE
Reported SBP MAE 0.208 (R² 0.996), DBP MAE 0.173 (R² 0.996).

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG); Form factor (finger). Method: Method. Target: Blood pressure.SetupSignals: PPGSignalsPPGForm factor: fingerForm factorfingerMethodMethodTargetBlood pressureBlood pressure

Datasets used· 1

Cite

@article{eitbeatbeatppgbpppgbpfea2026,