Paperdoi:10.1088/1361-6579/ad79b3
AF triggers in week-long ECG+wrist PPG (relational strength) — Pluščiauskaitė 2024
Physiological Measurement
TL;DR
This study looked at whether triggers detected in wearable signals line up with atrial fibrillation episodes. Thirty-five people with paroxysmal AF wore a chest ECG patch and a wrist PPG device for a week of normal life, and the patch data were used to detect physical exertion, stress, lying on the left side and sleep disturbance. Physical exertion was linked to the biggest rise in AF for the most patients, and PPG-detected AF tracked annotated AF with r = 0.62.
- Result: Physical exertion emerged as the trigger associated with the largest increase in relational strength for the largest number of patients ( p < 0.01).
- Result: The relational strength of the detected AF exhibits a moderate correlation with the relational strength of annotated AF, with r = 0.66 for ECG-based AF detection and r = 0.62 for PPG-based AF detection.
Abstract
Objective. Despite the growing interest in understanding the role of triggers of paroxysmal atrial fibrillation (AF), solutions beyond questionnaires to identify a broader range of triggers remain lacking. This study aims to investigate the relation between triggers detected in wearable-based physiological signals and the occurrence of AF episodes. Approach. Week-long physiological signals were collected during everyday activities from 35 patients with paroxysmal AF, employing an ECG patch attached to the chest and a photoplethysmogram (PPG)-based wrist-worn device. The signals acquired by the patch were used for detecting potential triggers due to physical exertion, psychophysiological stress, lying on the left side, and sleep disturbances. To assess the relation between detected triggers and the occurrence of AF episodes, a measure of relational strength is employed accounting for pre- and post-trigger AF burden. The usefulness of ECG- and PPG-based AF detectors in determining AF burden and assessing the relational strength is also analyzed. Main results. Physical exertion emerged as the trigger associated with the largest increase in relational strength for the largest number of patients (p < 0.01). On the other hand, no significant difference was observed for psychophysiological stress and sleep disorders. The relational strength of the detected AF exhibits a moderate correlation with the relational strength of annotated AF, with r = 0.66 for ECG-based AF detection and r = 0.62 for PPG-based AF detection. Conclusions. The findings indicate a patient-specific increase in relational strength for all four types of trigger. Significance. The proposed approach has the potential to facilitate the implementation of longitudinal studies and can serve as a less biased alternative to questionnaire-based AF trigger detection.
Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Devices
Keywords
Datasets used
How it works
- Cohort
- 35 patients
Cite this paper
Pluščiauskaitė, V., Sološenko, A., Jančiulevičiūtė, K., Marozas, V., Sörnmo, L., & Petrėnas, A. (2024). AF triggers in week-long ECG+wrist PPG (relational strength) — Pluščiauskaitė 2024. Physiological Measurement. https://doi.org/10.1088/1361-6579/ad79b3
Pluščiauskaitė, Vilma, Andrius Sološenko, Karolina Jančiulevičiūtė, Vaidotas Marozas, Leif Sörnmo, and Andrius Petrėnas. 2024. "AF triggers in week-long ECG+wrist PPG (relational strength) — Pluščiauskaitė 2024." Physiological Measurement. https://doi.org/10.1088/1361-6579/ad79b3.
Pluščiauskaitė, V., Sološenko, A., Jančiulevičiūtė, K., Marozas, V., Sörnmo, L. and Petrėnas, A. (2024) 'AF triggers in week-long ECG+wrist PPG (relational strength) — Pluščiauskaitė 2024', Physiological Measurement. doi: 10.1088/1361-6579/ad79b3.
Pluščiauskaitė, Vilma, et al. "AF triggers in week-long ECG+wrist PPG (relational strength) — Pluščiauskaitė 2024." Physiological Measurement, 2024. https://doi.org/10.1088/1361-6579/ad79b3.
V. Pluščiauskaitė, A. Sološenko, K. Jančiulevičiūtė, V. Marozas, L. Sörnmo, and A. Petrėnas, "AF triggers in week-long ECG+wrist PPG (relational strength) — Pluščiauskaitė 2024," Physiological Measurement, 2024, doi: 10.1088/1361-6579/ad79b3.
@article{plusciauskaite2024triggers,
title = {{AF triggers in week-long ECG+wrist PPG (relational strength) — Pluščiauskaitė 2024}},
author = {Pluščiauskaitė, Vilma and Sološenko, Andrius and Jančiulevičiūtė, Karolina and Marozas, Vaidotas and Sörnmo, Leif and Petrėnas, Andrius},
year = {2024},
journal = {Physiological Measurement},
doi = {10.1088/1361-6579/ad79b3}
}Added to the ChatPPG research hub