Paperdoi:10.5281/zenodo.24394553

Testing rhythm discrimination and channel-quality transfer in simulation-trained ECG–PPG fusion

Venue listedDated Nov 20, 2026Added Nov 20, 2026

  • HY
  • AY
  • AA

Authors: Hüseyin Yanık, Ali Yıldız, Ali Akdağlı

Manuscript submitted to Biomedical Signal Processing and Control (per deposit); analysis supplement Zenodo 10.5281/zenodo.24394553 (v1, 2026-11-20)

TL;DR

A quality-gated late-fusion network (QG-Late-P) trained only on simulated paired ECG and PPG was tested zero-shot on real AF data. On ICU MIMIC PERform AF it reached subject-level AUROC 0.970, but plain equal-weight or ungated fusion did as well or better, so the learned quality gate added nothing measurable. On ambulatory wrist PPG plus ECG (Vilnius, 35 patients) fusion reached AUROC 0.887 while ECG alone reached 0.931 and wrist PPG alone only 0.673.

  • Form factor: simulation-trained; evaluated on ICU finger PPG (MIMIC PERform AF) and ambulatory wrist PPG + ECG (Vilnius AF)

Abstract

Analysis supplement for the manuscript "Testing rhythm discrimination and channel-quality transfer in simulation-trained ECG–PPG fusion" (submitted to Biomedical Signal Processing and Control). Contains the code, the three QG-Late-P checkpoints and the ungated comparator checkpoints trained on simulated paired ECG–PPG signals, the simulated windows, cross-validation folds, all patient- and window-level predictions on MIMIC PERform AF, the Vilnius ambulatory AF cohort and MIMIC-II expert signal-quality labels, and the result tables reported in the manuscript. Third-party waveform files are referenced, not redistributed; see DEPOSIT_NOTES.md and LICENSES.md.

Verbatim from DataCite (opens in a new tab) · Licence: https://creativecommons.org/licenses/by/4.0/legalcode

Results on ChatPPG leaderboards · 1

All leaderboards
LeaderboardMethodResultRank
MIMIC PERform AUROCAtrial fibrillation detectionTesting rhythm discrimination and…0.97AUROC, higher is better#1 of 1

1 row is credited to this paper. Ranks apply within each leaderboard only, as reported by the source.

Tasks & signals

Tasks

Atrial fibrillation detectionAF / rhythmSignal quality

Signals

Keywords

AFECG PPG FusionQuality Gated Late FusionSimulation TrainedSim to RealZero ShotMIMIC PERform AFVilnius AF

Datasets used

How it works

How Method works: Setup → Method → TargetSetup: Signals (ECG, PPG); Form factor (simulation-trained; evaluated on ICU finger PPG (MIMIC PERform AF) and ambulatory wrist PPG + ECG (Vilnius AF)). Method: Method. Target: AF / rhythm; Signal quality.SetupSignals: ECG, PPGSignalsECG, PPGForm factor: simulation-trained; evaluated on ICU finger PPG (MIMIC PERform AF) and ambulatory wrist PPG + ECG (Vilnius AF)Form factorsimulation-trained; evaluated on ICU…MethodMethodTargetAF / rhythmAF / rhythmSignal qualitySignal quality

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Yanık, H., Yıldız, A., & Akdağlı, A. (2026). Testing rhythm discrimination and channel-quality transfer in simulation-trained ECG–PPG fusion. Manuscript submitted to Biomedical Signal Processing and Control. https://doi.org/10.5281/zenodo.24394553
Yanık, Hüseyin, Ali Yıldız, and Ali Akdağlı. 2026. "Testing rhythm discrimination and channel-quality transfer in simulation-trained ECG–PPG fusion." Manuscript submitted to Biomedical Signal Processing and Control. https://doi.org/10.5281/zenodo.24394553.
Yanık, H., Yıldız, A. and Akdağlı, A. (2026) 'Testing rhythm discrimination and channel-quality transfer in simulation-trained ECG–PPG fusion', Manuscript submitted to Biomedical Signal Processing and Control. doi: 10.5281/zenodo.24394553.
Yanık, Hüseyin, et al. "Testing rhythm discrimination and channel-quality transfer in simulation-trained ECG–PPG fusion." Manuscript submitted to Biomedical Signal Processing and Control, 2026. https://doi.org/10.5281/zenodo.24394553.
H. Yanık, A. Yıldız, and A. Akdağlı, "Testing rhythm discrimination and channel-quality transfer in simulation-trained ECG–PPG fusion," Manuscript submitted to Biomedical Signal Processing and Control, 2026, doi: 10.5281/zenodo.24394553.
@article{yank2026testing,
  title         = {{Testing rhythm discrimination and channel-quality transfer in simulation-trained ECG–PPG fusion}},
  author        = {Yanık, Hüseyin and Yıldız, Ali and Akdağlı, Ali},
  year          = {2026},
  journal       = {Manuscript submitted to Biomedical Signal Processing and Control},
  doi           = {10.5281/zenodo.24394553}
}

Added to the ChatPPG research hub