Dataset

STU-BA PPG Blood Glucose Dataset (Zenodo)

This open database pairs PPG signals with reference capillary blood glucose readings. Data came from 21 healthy controls and 3 people with type 1 diabetes, recorded with an in-house six-channel ePPG device at 530, 655 and 940 nm. The release also includes record-level signal quality-control files.

Published
Zenodo, 2026
Cohort
24 volunteers (21 healthy, 3 with type 1 diabetes)
Device
in-house 6-channel ePPG at 530, 655 and 940 nm
Reference
capillary blood glucose
License
CC0 1.0
At a glance
Type
Dataset
Access
Open
Subjects
24
Signals
PPGIMU
PPG sites
Finger
Setting
Not reported
Wrist
No
Raw waveforms
Yes
Updated
Nov 16, 2026

Original description

This project introduces an open-access database of photoplethysmography (PPG) signals annotated with reference capillary blood glucose measurements.. While PPG is widely used for heart rate monitoring, its application in metabolic sensing is a growing area of research that suffers from a lack of quality, publicly available data. Our database comprises 125 signal samples from 24 volunteers. To ensure a wide-ranging glycemic profile, data was collected from 21 healthy controls and 3 individuals with Type 1 Diabetes Mellitus (T1DM). The resulting dataset accounts for a broad metabolic spectrum, ranging from normal glucose levels to the significant glycemic excursions associated with diabetes. Data collection was performed with the in house developed multichannel ePPG device, operating across three different wavelengths (530 nm, 655 nm, 940 nm) through a 6-channel configuration. To complement the PPG data, tri-axial accelerometry data were acquired simultaneously too. To facilitate use in deep learning and signal processing research, the data is provided in wfdb format.

Background

Effective management of diabetes mellitus—a condition with rising global prevalence [1]—necessitates daily monitoring of blood glucose levels. Non-invasive monitoring of glycemia has gained attention within the scientific community as an alternative to current diagnostic standards, which rely on invasive or semi-invasive measurements that diminish patient comfort [2]. Various diagnostic modalities have emerged as potential solutions for non-invasive glycemic monitoring, including photoplethysmography, electrochemical impedance spectroscopy, reverse iontophoresis, and microwave-based sensing [3, 4]. Among the most promising approaches is PPG, a suitable modality for non-invasive glucose estimation due to its ability to capture the physiological impact of blood glucose on the peripheral circulatory system. Moreover, owing to its technical simplicity and compatibility with wearable technology, PPG offers a discreet alternative for continuous glycemic monitoring [2, 5].

Extracting relevant diagnostic features from the PPG waveform requires sophisticated algorithmic frameworks capable of processing optical signals and establishing a reliable correlation with blood glucose levels [6]. In recent years, artificial intelligence and machine learning have found increasingly broad applications in this domain, providing the tools necessary to decode non-linear relationships between PPG and glycemia values [7]. Developing a robust artificial intelligence model for mapping PPG signals to blood glucose levels necessitates the availability of comprehensive, open-access datasets. Such data are essential both for model training and for establishing standardized benchmarks to compare diverse architectural approaches [8]. The objective of this PPG database, annotated with corresponding blood glucose levels, is to provide the scientific community with open-access data. By doing so, it facilitates the development and validation of artificial intelligence models specifically designed for non-invasive glycemic monitoring.

Methods

Data acquisition was performed using the ePPG, a custom-engineered wearable platform. The device was designed and fabricated at the Faculty of Electrical Engineering and Information Technology, Slovak University of Technology (FEI STU), to facilitate multi-sensor physiological monitoring [9]. The ePPG device recorded all six PPG channels simultaneously at a sampling rate of 100 Hz. To facilitate motion artifact characterization, PPG data capture was synchronized with a built-in three-axis accelerometer, which monitored physical movement across all three spatial axes throughout the recording process.

Reference blood glucose levels were established via capillary fingerstick measurements using a blood glucose monitor GL 49 Beurer glucometer on the same hand as the ePPG device. Following hand sanitization and fingertip disinfection, a blood sample was collected for the initial readout. The ePPG device was then secured to the left thumb. To ensure data integrity, signal recording commenced only after the PPG waveform reached a stable, artifact-free state, with this stabilization phase strictly limited to a maximum of one minute. The duration for each following PPG signal recording was at least 30 seconds.

Data Description

The dataset comprises 125 records obtained from 24 distinct subjects. Each record consists of six PPG channels captured using two photodetectors across three wavelengths [9]: green (530 nm), red (655 nm), and infrared (940 nm). These signals are labeled G1, R1, IR1 and G2, R2, IR2, where the letter indicates the wavelength (G, R, or IR), and the numerical suffix identifies the specific detector. Signal values are expressed in arbitrary units (a.u.). Additionally, each record includes synchronized triaxial accelerometer data (X, Y, and Z components) for motion tracking.

The dataset is structured in the WFDB format, where each record is comprised of three distinct files: a header file with the .hea extension, a binary data file with the .dat extension, and an annotation file with the .atr extension.

Individual records are organized into multiple directories labelled Subject_xyz in root directory. Each directory contains all records acquired from a single volunteer. The number of records per participant is not uniform, and the duration of individual recordings is trimmed to 30 seconds. In general, the records was administered at various times throughout the day—encompassing pre-prandial, post-prandial, and inter-meal intervals—without dietary restrictions. In cases where multiple measurements were obtained per subject, these sessions were conducted across several different days.

Demographic and clinical data for each participant are stored in a file named subjects.csv, located in the root directory. For each subject, the recorded attributes include a unique identifier (ID), age, sex (F = female, M = male), height, weight, and the presence of T1DM. Within the subject cohort, 3 individuals were diagnosed with Type 1 diabetes, while the remaining participants were normoglycemic. This demographic and clinical data is also additionally incorporated into the header file (.hea) of each respective record.

The annotation file (.atr) contains blood glucose levels (measured in mmol/L), which were manually recorded during the session. These reference measurements were obtained immediately prior to the PPG acquisition process (maximum with 1min delay), ensuring that glycemia data was collected shortly after each PPG recording for temporal alignment. In the annotation file (.atr), each annontation is timestamped to coincide with the first sample of the recording.

Quality-Control Annotations In addition to the raw recordings, the record distributes two CSV files with the results of the signal quality control described in the accompanying data article:

qc_records.csv - one row per record, with record-level quality verdicts: the number of PPG channels passing quality control, the best channel’s fraction of analysable 8-second windows, median heart rate across passing channels, an accelerometer-derived motion index, and the longest run of consecutive clean pulses together with its channel and start/end times in seconds, allowing clean segments to be extracted directly without re-running any analysis. qc_channels.csv - one row per record–channel pair (750 rows), with per-channel signal quality metrics: perfusion index, skewness and relative-power signal quality indices, detected heart rate and inter-beat-interval variability, fraction of analysable windows, beat-template correlation with template-validity flag, and the longest clean pulse run per channel.

Quality control was computed on the 0.5–8 Hz band-passed signals in 8-second windows advanced by 2 seconds, with beat-level assessment by correlation against each record's own median beat template (threshold 0.80), applied only where the template is itself pulse-shaped.

Usage Notes There are few publicly available PPG datasets accompanied by well-curated blood glucose annotations. Our primary objective in developing this database was to address this scarcity. We anticipate that this dataset will be instrumental for the development and objective benchmarking of non-invasive glycemia estimation algorithms. Records failing quality control are deliberately retained to reflect realistic wearable acquisition conditions and to support research on signal quality itself; they can be excluded with a single filter on the record_passes or best_clean_run columns of qc_records.csv.

Ethics The study was conducted in accordance with the principles of the Declaration of Helsinki. The study protocol was reviewed and approved by the Ethics Committee of the F. D. Roosevelt Faculty Hospital with Polyclinic in Banská Bystrica, Slovakia (approval No. 18/2021). All participants provided written informed consent prior to enrollment. All data were de-identified in accordance with institutional and ethical guidelines before public release.

Acknowledgments This work was funded by the EU NextGenerationEU through the Recovery and Resilience Plan for Slovakia under the project No. 09I05-03-V02-00061.

Verbatim fromZenodo· Licence: cc-zero

STU-BA PPG Blood Glucose Dataset (Zenodo): overview

The Photoplethysmography (PPG) Dataset for Non-Invasive Blood Glucose Monitoring from the Slovak University of Technology in Bratislava (Berki and Mateasik, Zenodo) holds 125 thumb PPG records from 24 volunteers: 21 normoglycemic and 3 with type 1 diabetes. A custom ePPG device recorded six channels (green 530 nm, red 655 nm and infrared 940 nm on two photodetectors) at 100 Hz with a 3-axis accelerometer, and each record carries a Beurer GL 49 fingerstick glucose value. It is released under CC0 with quality-control tables and benchmark code.

What's inside

Participants
24 (21 healthy, 3 type 1 diabetes); age, sex, height, weight, T1DM flag in subjects.csv
Records
125, trimmed to 30 s; number per person varies, collected on different days and times
PPG
6 channels: G1, R1, IR1, G2, R2, IR2 (530 / 655 / 940 nm, two detectors), 100 Hz, left thumb
Motion
Synchronized 3-axis accelerometer
Glucose reference
Beurer GL 49 capillary fingerstick, mmol/L, taken within 1 min of each recording, stored in the .atr annotation
Quality control
qc_records.csv (one row per record) and qc_channels.csv (750 rows, one per record-channel)
Format
WFDB (.hea / .dat / .atr) in Subject_xyz folders; MIT-licensed code in stuba_ppg_bgl_code.zip

How to access it

Host: Zenodo

  1. Download stuba_ppg_bgl_dataset.zip (about 5.9 MB) and the two QC CSVs from Zenodo; no registration.
  2. Read records with the wfdb Python package.
  3. Drop records that fail QC with the record_passes or best_clean_run columns of qc_records.csv if you want clean signals only.

Licence: Creative Commons Zero v1.0 Universal (CC0 1.0); benchmark code MIT

What it allows: Any use, including commercial, with no conditions (citation still expected academically).

Load STU-BA PPG Blood Glucose Dataset (Zenodo) in Python

Untestedpip install wfdb numpy
import glob
import wfdb

for hea in sorted(glob.glob("stuba_ppg_bgl_dataset/Subject_*/*.hea"))[:3]:
    rec = hea[:-4]
    r = wfdb.rdrecord(rec)                 # 6 PPG channels + accelerometer X/Y/Z at 100 Hz
    ann = wfdb.rdann(rec, "atr")          # glucose reference (mmol/L)
    print(rec, r.sig_name, r.p_signal.shape, ann.aux_note or ann.symbol)

# mg/dL = mmol/L * 18.016

Caveats

  • 24 people: split by subject. Several records per subject were taken on different days, so window-level splits leak identity.
  • Only 3 participants have type 1 diabetes; most glucose values are normal, so high and low ranges are sparse.
  • Records failing QC are kept on purpose; filter with qc_records.csv.
  • Glucose is in mmol/L, not mg/dL; convert before comparing with other datasets.

Similar datasets

DatasetSubjectsSignalsLicence
PPG Signals for Blood Glucose Measurement (Kermani / Mendeley)23ppgCC BY 4.0
BIG IDEAs Lab Glycemic Variability and Wearable Device Data16ppg, accel, skin-temp, eda, cgmOpen Data Commons Attribution License v1.0
Brno University of Technology Smartphone PPG Database (BUT PPG)50ppg, ecgCC BY 4.0
Smartwatch PPG paired with CGM glucose (Zenodo)5ppg, cgmCC BY 4.0

Sources: Zenodo record 21978226 · Updated 2026-10-16

STU-BA PPG Blood Glucose Dataset (Zenodo): ChatPPG research summary card

Key numbers

24
Subjects
1
Reference labels
GLUCOSE
100 Hz
Released sampling rate
6-ch PPG 100 Hz; 3-axis accel 100 Hz; 30 s WFDB records

How it works

How STU-BA PPG Blood Glucose Dataset (Zenodo) works: Devices & body sites → Signals recorded → TasksDevices & body sites: Finger (PPG site). Signals recorded: STU-BA PPG Blood Glucose Dataset (Zenodo), 24 subjects · 100 Hz, signals PPG, IMU. Tasks: Glucose.Devices & body sitesFinger: PPG siteFingerPPG siteSignals recordedSTU-BA PPG Blood Glucose…24 subjects · 100 HzPPGxyzIMUTasksGlucoseGlucose

No model in the hub reports results on this dataset yet.

Sampling
6-ch PPG 100 Hz; 3-axis accel 100 Hz; 30 s WFDB records
Reference labels
glucose
Device roles
Study wearable (IMU)

FAQ

How many subjects and records are in the STU-BA PPG glucose dataset?

125 records from 24 volunteers: 21 normoglycemic controls and 3 people with type 1 diabetes.

Which PPG wavelengths does it include?

Green 530 nm, red 655 nm and infrared 940 nm, each on two photodetectors, for six channels at 100 Hz, plus a 3-axis accelerometer.

Can I use it commercially?

Yes. The data are CC0 1.0 and the benchmark code is MIT.

Cite this dataset

Cite this dataset with the fields recorded here. Check it against the publisher before submitting.

STU-BA PPG Blood Glucose Dataset (Zenodo) [Data set]. (n.d.). zenodo. https://doi.org/10.5281/zenodo.21978226
@misc{stubappgbglstuba,
  title         = {{STU-BA PPG Blood Glucose Dataset (Zenodo)}},
  howpublished  = {zenodo},
  doi           = {10.5281/zenodo.21978226}
}

Cite the ChatPPG record

Cite the dated snapshot 2026-10 for a fixed, reproducible version. Please also cite the original publications listed above.

APA

ChatPPG. (2026). STU-BA PPG Blood Glucose Dataset (Zenodo): dataset record (Version 2026-10) [Data set]. ChatPPG Research Hub. https://chatppg.com/research/datasets/stuba-ppg-bgl

BibTeX
@misc{chatppg_dataset_stuba_ppg_bgl,
  author       = {{ChatPPG}},
  title        = {{STU-BA PPG Blood Glucose Dataset (Zenodo): dataset record}},
  year         = {2026},
  month        = nov,
  version      = {2026-10},
  howpublished = {\url{https://chatppg.com/research/datasets/stuba-ppg-bgl}},
  note         = {ChatPPG Research Hub, Snapshot 2026-10, https://chatppg.com/research/snapshots/2026-10}
}
CITATION.cff
cff-version: 1.2.0
message: "If you use this resource, please cite it as below."
type: dataset
title: "STU-BA PPG Blood Glucose Dataset (Zenodo): dataset record"
authors:
  - name: "ChatPPG"
url: "https://chatppg.com/research/datasets/stuba-ppg-bgl"
repository-artifact: "https://chatppg.com/research/snapshots/2026-10"
version: "2026-10"
date-released: "2026-11-16"

History

  1. Record updated