Paperdoi:10.1109/JSEN.2026.3753864
Motion-Constrained Viability of IMU-Based Heart Rate Estimation During Live-Fire Wildfire Suppression (SCG/GCG HR on 6 firefighters; usable low-motion windows 2–70% by threshold; GCG thorax 88.2% within ±5 bpm)
IEEE Sensors Journal, accepted 2026 (early access)
TL;DR
Tests heart-rate estimation from IMU-based seismocardiography and gyrocardiography in six professional firefighters during an outdoor live-fire exercise, with IMUs at the jugular notch and front of the chest and a chest-strap ECG reference. Usable low-motion windows covered only about 2% to 14% of the time at strict thresholds and close to 70% at the loosest. Within usable windows, chest gyrocardiography was best, with 88.2% of estimates within ±5 bpm.
- Form factor: chest (jugular + anterior thoracic IMUs)
Abstract
Opportunistic heart rate (HR) assessment in wildfire suppression scenarios could support the evaluation of cardiovascular strain, physiological stress, and potential risk conditions in firefighters operating under extreme loads. Inertial measurement units (IMUs) represent a promising unobtrusive solution, as they can capture cardiac mechanical vibrations through seismocardiography (SCG) and gyrocardiography (GCG), but intense and irregular body motion severely limits reliable HR estimation. This study evaluates the field viability of intermittent IMU-based HR estimation during an outdoor live fire exercise, involving six professional firefighters equipped with two IMUs placed at the jugular (JR) and anterior thoracic (ATR) regions, and a chest strap ECG-derived reference. Motion intensity was quantified using acceleration vector magnitude (VMU), exploring thresholds from 0.001 g to 0.20 g and 5 s to 10 s windows; coverage of low-motion windows was the primary viability outcome. Very strict VMU thresholds (0.001–0.005 g) retained only approximately 2–14% of samples, while coverage increased to about 25% at 0.01 g and approached 70% at 0.20 g. A VMU threshold of 0.05 g with 10 s windows emerged as an in-sample candidate trade-off between window availability and HR agreement. Within these windows, GCG at ATR showed the highest descriptive agreement with ECG, with 88.2% of pooled estimates within ±5 bpm and 89.6% within ±10 bpm. System Usability Scale and Technology Acceptance Model scores indicated high acceptability of the IMU system, supporting the practical feasibility of intermittent IMU-based HR assessment in wildfire operations when motion quality windowing is applied.
Verbatim from OpenAlex (opens in a new tab) · Abstract via OpenAlex (publisher-deposited); © the authors/publisher
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
How it works
Cite this paper
Pinnelli, M., Marsella, S., Tossut, F., Schena, E., Setola, R., & Massaroni, C. (2026). Motion-Constrained Viability of IMU-Based Heart Rate Estimation During Live-Fire Wildfire Suppression (SCG/GCG HR on 6 firefighters; usable low-motion windows 2–70% by threshold; GCG thorax 88.2% within ±5 bpm). IEEE Sensors Journal, accepted 2026. https://doi.org/10.1109/JSEN.2026.3753864
Pinnelli, Mariangela, Stefano Marsella, Fabio Tossut, Emiliano Schena, Roberto Setola, and Carlo Massaroni. 2026. "Motion-Constrained Viability of IMU-Based Heart Rate Estimation During Live-Fire Wildfire Suppression (SCG/GCG HR on 6 firefighters; usable low-motion windows 2–70% by threshold; GCG thorax 88.2% within ±5 bpm)." IEEE Sensors Journal, accepted 2026. https://doi.org/10.1109/JSEN.2026.3753864.
Pinnelli, M., Marsella, S., Tossut, F., Schena, E., Setola, R. and Massaroni, C. (2026) 'Motion-Constrained Viability of IMU-Based Heart Rate Estimation During Live-Fire Wildfire Suppression (SCG/GCG HR on 6 firefighters; usable low-motion windows 2–70% by threshold; GCG thorax 88.2% within ±5 bpm)', IEEE Sensors Journal, accepted 2026. doi: 10.1109/JSEN.2026.3753864.
Pinnelli, Mariangela, et al. "Motion-Constrained Viability of IMU-Based Heart Rate Estimation During Live-Fire Wildfire Suppression (SCG/GCG HR on 6 firefighters; usable low-motion windows 2–70% by threshold; GCG thorax 88.2% within ±5 bpm)." IEEE Sensors Journal, accepted 2026, 2026. https://doi.org/10.1109/JSEN.2026.3753864.
M. Pinnelli, S. Marsella, F. Tossut, E. Schena, R. Setola, and C. Massaroni, "Motion-Constrained Viability of IMU-Based Heart Rate Estimation During Live-Fire Wildfire Suppression (SCG/GCG HR on 6 firefighters; usable low-motion windows 2–70% by threshold; GCG thorax 88.2% within ±5 bpm)," IEEE Sensors Journal, accepted 2026, 2026, doi: 10.1109/JSEN.2026.3753864.
@article{pinnelli2026motionconstrained,
title = {{Motion-Constrained Viability of IMU-Based Heart Rate Estimation During Live-Fire Wildfire Suppression (SCG/GCG HR on 6 firefighters; usable low-motion windows 2–70\% by threshold; GCG thorax 88.2\% within ±5 bpm)}},
author = {Pinnelli, Mariangela and Marsella, Stefano and Tossut, Fabio and Schena, Emiliano and Setola, Roberto and Massaroni, Carlo},
year = {2026},
journal = {IEEE Sensors Journal, accepted 2026},
doi = {10.1109/JSEN.2026.3753864}
}Record updated
Added to the ChatPPG research hub