Paperdoi:10.54254/2753-8818/2026.es37117
Beyond average accuracy: motion-related failure patterns in wrist PPG heart-rate monitoring (Xu, Theor. Nat. Sci. 2026)
Theoretical and Natural Science (EWA Publishing), 2026-09-22
TL;DR
Uses PPG-DaLiA (15 participants, Empatica E4 wrist PPG + chest ECG). 8-s windows, 2-s step; HR from a dominant-frequency PPG method. A large error is >10 bpm vs ECG.
- Form factor: wrist
Abstract
Wrist-worn photoplethysmography (PPG) enables unobtrusive heart rate monitoring, but motion-related errors tend to cluster under specific conditions and are often masked by aggregate accuracy metrics. This study characterized those failure patterns and assessed whether wrist-sensor features could identify unreliable estimates in previously unseen participants. PPG-DaLiA recordings from 15 participants, acquired with an Empatica E4 and synchronized chest electrocardiography during daily-life activities, were segmented into 8-s windows with a 2-s step. Heart rate was estimated using a transparent dominant-frequency PPG method. A large error was defined a priori as an absolute deviation of more than 10 beats per minute (bpm) relative to the ECG-derived reference. Motion intensity, acceleration-band power, PPG-acceleration spectral overlap, peak dominance and spectral entropy were used as reliability predictors. Of 47,182 non-transition windows, 14,622 (31.0%) met the large-error criterion. Failure prevalence differed substantially by activity, from 5.8% during sitting to 63.8% during stair climbing. In leave-one-subject-out validation, a motion-only model achieved an AUROC of 0.743, wrist-signal features increased AUROC to 0.851, and activity context increased it to 0.864. Wrist PPG reliability is therefore condition dependent, and an interpretable signal-based reliability flag may complement point heart-rate estimates. External prospective validation is required before clinical or consumer deployment.
Verbatim from the publisher's DOI record (opens in a new tab) · Abstract as deposited by the publisher with Crossref; © the authors/publisher
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Devices
Keywords
Datasets used
How it works
Cite this paper
Xu, A. (2026). Beyond average accuracy: motion-related failure patterns in wrist PPG heart-rate monitoring (Xu, Theor. Nat. Sci. 2026). Theoretical and Natural Science. https://doi.org/10.54254/2753-8818/2026.es37117
Xu, Angel. 2026. "Beyond average accuracy: motion-related failure patterns in wrist PPG heart-rate monitoring (Xu, Theor. Nat. Sci. 2026)." Theoretical and Natural Science. https://doi.org/10.54254/2753-8818/2026.es37117.
Xu, A. (2026) 'Beyond average accuracy: motion-related failure patterns in wrist PPG heart-rate monitoring (Xu, Theor. Nat. Sci. 2026)', Theoretical and Natural Science. doi: 10.54254/2753-8818/2026.es37117.
Xu, Angel "Beyond average accuracy: motion-related failure patterns in wrist PPG heart-rate monitoring (Xu, Theor. Nat. Sci. 2026)." Theoretical and Natural Science, 2026. https://doi.org/10.54254/2753-8818/2026.es37117.
A. Xu, "Beyond average accuracy: motion-related failure patterns in wrist PPG heart-rate monitoring (Xu, Theor. Nat. Sci. 2026)," Theoretical and Natural Science, 2026, doi: 10.54254/2753-8818/2026.es37117.
@article{xu2026beyond,
title = {{Beyond average accuracy: motion-related failure patterns in wrist PPG heart-rate monitoring (Xu, Theor. Nat. Sci. 2026)}},
author = {Xu, Angel},
year = {2026},
journal = {Theoretical and Natural Science},
doi = {10.54254/2753-8818/2026.es37117}
}Added to the ChatPPG research hub