Paperdoi:10.3390/s26196169

ECG-Based Emotion Recognition Using Beat-Level Complementary Feature Fusion

Venue listedDated Sep 29, 2026Added Nov 23, 2026

Sensors 26(19):6169, 2026 (online 2026-09-29)

TL;DR

Dual-path ECG emotion recognition model that fuses a morphology-stable path built from weighted representative beats with a beat-wise attention path, plus adaptive dilated convolution and beat-oriented augmentation. On WESAD 3-class leave-one-subject-out it reached mean macro-F1 43.39%, close to the best comparator with the fewest operations, and 76.72% with short within-record personalization. Recognition mainly separated stress, and DREAMER results stayed below uniform random baselines.

Abstract

Physiological-signal-based emotion recognition has received attention in human–computer interaction. Electrocardiograms (ECGs) are readily acquired, and short windows contain repeated beat morphology and beat-wise variations that single-window encoding struggles to separate. Multiscale morphology modeling and training-sample diversity remain limited. We therefore propose Complementary Feature Fusion Dual-Path (CFF-DP), an ECG emotion recognition framework using beat-level complementary feature fusion, with three components: (1) a dual-path framework, where the morphology-stable path constructs representative beats with window-adaptive Gaussian weights, while the morphology-difference path combines beat-wise encoding, positional encoding, and additive attention; gated fusion integrates representations; (2) adaptive dilated convolution (ADConv), which extracts multiscale beat-morphology features using shared kernels and input-dependent scale weights; and (3) deviation-based beat-oriented augmentation (DBOA), which adjusts real-noise injection probability and target signal-to-noise ratio according to morphological deviation. CFF-DP achieved 43.39% mean Macro-F1, close to the best comparator, with the fewest multiply–accumulate operations in five-seed WESAD three-class leave-one-subject-out (LOSO) evaluation, although recognition mainly distinguishes stress, with limited amusement discrimination. With short-gap calibration and testing within the same recording, fine-tuning using 40 s per class achieved 76.72% Macro-F1, exceeding six comparators. Binary DREAMER LOSO retained WESAD hyperparameters: valence Macro-F1 exceeded six comparators, whereas arousal fell below four; both remained below uniform random baselines, indicating limited recognition under current experimental conditions. The framework combines computational efficiency with within-record personalization advantages, although cross-subject recognition remains limited.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Stress

Signals

Keywords

T AFFECTEmotion RecognitionWesadDreamerLosoPersonalizationData AugmentationLightweight

Datasets used

How it works

How Method works: Setup → Method → TargetSetup: Signals (ecg). Method: Method. Target: Stress.SetupSignals: ecgSignalsecgMethodMethodTargetStressStress

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

ECG-Based Emotion Recognition Using Beat-Level Complementary Feature Fusion. (2026). Sensors , 2026, 26(19), 6169. https://doi.org/10.3390/s26196169
@article{pengguocffdpbeat2026ecgbased,
  title         = {{ECG-Based Emotion Recognition Using Beat-Level Complementary Feature Fusion}},
  year          = {2026},
  journal       = {Sensors , 2026},
  volume        = {26},
  number        = {19},
  pages         = {6169},
  doi           = {10.3390/s26196169}
}

Added to the ChatPPG research hub