This Mayo Clinic study followed 100,586 patients who had both an echocardiogram and an ECG, focusing on those whose AI-ECG score flagged low ejection fraction even though their measured EF was normal. These false-positive patients had an echocardiographic abnormality 97% of the time. Over a median of 2.7 years they had higher mortality than true negatives (age- and sex-adjusted HR 1.64), especially when their echo was also abnormal.
- Result: 97% of AI-ECG false positives had an echo abnormality
- Result: mortality HR 1.64 (95% CI 1.55-1.73) vs true negatives
Abstract
BackgroundAn artificial intelligence (AI)-based electrocardiogram (ECG) model identifies patients with a higher likelihood of low ejection fraction (EF). Patients with an abnormal AI-ECG score but normal EF (false positives; FP) more often developed future low EF.ObjectiveThe purpose of this study was to evaluate echocardiographic characteristics and all-cause mortality risk in FP patients.MethodsPatients with transthoracic echocardiography and ECG were classified retrospectively into FP, true negatives (TN) (EF ≥50%, normal AI-ECG), true positives (TP) (EF ResultsOf 100,586 patients (median age 63 years; 45.5% females), 79% were TN, 7% FP, 5% FN, and 8% TP. FPs had more echocardiographic abnormalities than TN but less than FN or TP patients. An echocardiographic abnormality was present in 97% of FPs. Over median 2.7 years, FPs had increased mortality risk (age and sex-adjusted HR: 1.64 [95% CI: 1.55-1.73]) vs TN. Age and sex-adjusted mortality was higher in FP with abnormal echocardiography than FP with normal echocardiography and to TN regardless of echocardiography result; FP with normal echocardiography had comparable mortality risk to TN with abnormal echocardiography.ConclusionsFP patients were more likely than TNs to have echocardiographic abnormalities with 97% of exams showing an abnormality. FP patients had higher mortality rates, especially when their echocardiograms also had an abnormality; the concomitant use of AI ECG and echocardiography helps in stratifying risk in patients with normal LVEF.
Verbatim from Europe PMC (opens in a new tab) · Licence: cc by-nc-nd
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Signals
How it works
- Cohort
- 100,586 patients (median age 63; 45.5% female)
Cite this paper