Paperdoi:10.1016/j.ijmedinf.2026.106758

A lightweight ECG model with teacher-derived integrated medical semantic preservation for cardiac disease screening (ECGFM-U-Lite)

Published articlePublished Jan 2027Added Oct 12, 2026

  • SM
  • WW
  • JY
  • JW
  • YW
  • YT

Authors: Shuangquan Ma, Wenyao Wang, Jie Yang, Jun Wen, Yawei Wang, Yi-Da Tang

International Journal of Medical Informatics

TL;DR

This study shrinks a unified ECG foundation model so it can run where compute and memory are limited. The result, ECGFM-U-Lite, is a compact 1D-MobileViT student built with a three-stage compression procedure. It reached an overall AUC of 0.862 against 0.918 for the teacher, keeping about 94% of the teacher's performance on rhythm and structure tasks.

  • Result: ECGFM-U-Lite achieved an overall AUC of 0.862, compared with 0.918 for the teacher, and retained 93.8% and 93.5% of teacher AUC for rhythm/morphology and structure/function tasks, respectively.

Abstract

Recent electrocardiogram (ECG) foundation models have extended ECG analysis from rhythm and morphology recognition to cardiac structure-function assessment, but the computational and memory requirements limit their use in resource-constrained settings. This study aimed to reduce the size and inference cost of a unified ECG foundation model while retaining its multitask performance and clinically relevant representations. We developed the ECGFM-U-Lite, a compact 1D-MobileViT student, using a three-stage compression procedure. Task outputs and intermediate representations were firstly transfered from teacher through structure-function consistent distillation, redundant channels were than removed by using physiologic attention-guided pruning while retaining anatomically informative pathways, and the structure-function-aware quantization strategy achieves adaptive precise quantification by leveraging the sensitivity discrepancies across different modules finally. The model was evaluated on six locked external cohorts. Its computational profile was examined on a laptop GPU and under Android- and Jetson-Nano-oriented ONNX Runtime simulations. ECGFM-U-Lite achieved an overall AUC of 0.862, compared with 0.918 for the teacher, and retained 93.8% and 93.5% of teacher AUC for rhythm/morphology and structure/function tasks, respectively. ECG-to-Text and Text-to-ECG R@1 values were 0.766 and 0.762 in the teacher-derived semantic consistency probe. The parameter count decreased from 86.4 M to 655.7 K, model size from 345.6 MB to 1.7 MB, and peak RAM from 320 MB to 4.4 MB. The inference process was 3.6-fold faster on the laptop GPU and approximately 3.7-fold faster in the simulated edge-oriented profiles. U-Lite substantially reduces the resource requirements of a unified ECG foundation model while preserving most of its external discrimination and teacher-derived cross-modal representation structure, providing a practical basis for subsequent evaluation on resource-constrained hardware.

Verbatim from Semantic Scholar (opens in a new tab) · Abstract via Semantic Scholar; © the authors/publisher

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Signals

Keywords

Foundation ModelKnowledge DistillationPruningQuantizationMobileViTEdgeECG Text RetrievalCardiac Screening

Models

How it works

How ECGFM-U-Lite (1D-MobileViT student distilled from a unified ECG FM) works: Setup → Method → ResultSetup: Signals (ECG). Method: ECGFM-U-Lite (1D-MobileViT student distilled from a unified ECG FM). Result: Result (ECGFM-U-Lite achieved an overall AUC of 0.862, compared with 0.918 for the teacher, and retained 93.8% and 93.5% of teacher AUC for rhythm/morphology and structure/function tasks, respectively.).SetupSignals: ECGSignalsECGMethodECGFM-U-Lite (1D-MobileViT…ResultResult: ECGFM-U-Lite achieved an overall AUC of 0.862, compared with 0.918 for the teacher, and retained 93.8% and 93.5% of teacher AUC for rhythm/morphology and structure/function tasks, respectively.ResultECGFM-U-Lite achieved an overall AUC of…

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Ma, S., Wang, W., Yang, J., Wen, J., Wang, Y., & Tang, Y.-D. (2027). A lightweight ECG model with teacher-derived integrated medical semantic preservation for cardiac disease screening (ECGFM-U-Lite). International Journal of Medical Informatics. https://doi.org/10.1016/j.ijmedinf.2026.106758
Ma, Shuangquan, Wenyao Wang, Jie Yang, Jun Wen, Yawei Wang, and Yi-Da Tang. 2027. "A lightweight ECG model with teacher-derived integrated medical semantic preservation for cardiac disease screening (ECGFM-U-Lite)." International Journal of Medical Informatics. https://doi.org/10.1016/j.ijmedinf.2026.106758.
Ma, S., Wang, W., Yang, J., Wen, J., Wang, Y. and Tang, Y.-D. (2027) 'A lightweight ECG model with teacher-derived integrated medical semantic preservation for cardiac disease screening (ECGFM-U-Lite)', International Journal of Medical Informatics. doi: 10.1016/j.ijmedinf.2026.106758.
Ma, Shuangquan, et al. "A lightweight ECG model with teacher-derived integrated medical semantic preservation for cardiac disease screening (ECGFM-U-Lite)." International Journal of Medical Informatics, 2027. https://doi.org/10.1016/j.ijmedinf.2026.106758.
S. Ma, W. Wang, J. Yang, J. Wen, Y. Wang, and Y.-D. Tang, "A lightweight ECG model with teacher-derived integrated medical semantic preservation for cardiac disease screening (ECGFM-U-Lite)," International Journal of Medical Informatics, 2027, doi: 10.1016/j.ijmedinf.2026.106758.
@article{ma2027lightweight,
  title         = {{A lightweight ECG model with teacher-derived integrated medical semantic preservation for cardiac disease screening (ECGFM-U-Lite)}},
  author        = {Ma, Shuangquan and Wang, Wenyao and Yang, Jie and Wen, Jun and Wang, Yawei and Tang, Yi-Da},
  year          = {2027},
  journal       = {International Journal of Medical Informatics},
  doi           = {10.1016/j.ijmedinf.2026.106758}
}

Added to the ChatPPG research hub