Paperdoi:10.1123/jmpb.2026-0037
Agreement between the third-generation Oura Ring and ActiGraph for moderate and vigorous physical activity (Blue et al., JMPB 2026)
Journal for the Measurement of Physical Behaviour 9 (2026)
TL;DR
Thirty-nine young adults wore an Oura Ring Gen3 and a waist ActiGraph for a week. Oura's daily moderate and MVPA minutes were close to ActiGraph on average (MVPA -2.8 min/day) but varied widely day to day (SD about 32 min/day, ICC 0.42), and Oura recorded slightly more vigorous activity.
- Form factor: ring
Abstract
Background :
Physical activity (PA) monitoring and promotion interventions commonly incorporate wearable fitness monitors. The Oura Ring is a commercially available smart ring, and although its accuracy for measuring heart rate variability and sleep is well-established, the accuracy of the Oura Ring’s PA estimates remain unknown. The purpose of this study was to evaluate the agreement between the third-generation Oura Ring and ActiGraph wGT3X-BT (reference method) estimates for moderate PA, vigorous PA, and moderate to vigorous PA (MVPA).
Methods :
Data from 39 adults (66% female, age: 24.6 ± 4.1 years) were analyzed. Participants wore an Oura Ring on their nondominant hand and Actigraph around their waist, simultaneously, for one week. 192 valid days were included in repeated-measures mixed effects models, comparing estimates of moderate, vigorous, and MVPA.
Results :
The mean difference between devices was −4.7 ± 30.0 min/day for moderate PA, 1.8 ± 8.5 min/day for vigorous PA, and −2.8 ± 31.9 min/day for MVPA. The Oura Ring predicted similar time in moderate PA ( b
0
= −3.35, 95% confidence interval, CI, [−9.9, 3.2], intraclass correlation coefficient [ICC] = .32, root mean square error = 22.9, p = .313) and MVPA ( b
0
= −0.91, 95% CI [−8.42, 6.60], ICC = .42, root mean square error = 22.48, p = .811) and significantly more time in vigorous PA than the ActiGraph ( b
0
= 1.99, 95% CI [0.41, 3.56], ICC = .15, root mean square error = 7.47, p = .014).
Conclusions :
The Oura Ring estimates of moderate PA, vigorous PA, and MVPA showed acceptable agreement with the ActiGraph reference method. The Oura Ring slightly underestimated moderate PA and MVPA and overestimated vigorous PA. Given its established accuracy for sleep and heart rate variability, the Oura Ring may offer a practical option for integrating MVPA assessment into multidomain behavioral monitoring.
Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: http://creativecommons.org/licenses/by-nc-nd/4.0
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
How it works
Cite this paper
Agreement between the third-generation Oura Ring and ActiGraph for moderate and vigorous physical activity (Blue et al., JMPB 2026). (2026). Journal for the Measurement of Physical Behaviour 9. https://doi.org/10.1123/jmpb.2026-0037
@article{bluebaezouragen32026agreement,
title = {{Agreement between the third-generation Oura Ring and ActiGraph for moderate and vigorous physical activity (Blue et al., JMPB 2026)}},
year = {2026},
journal = {Journal for the Measurement of Physical Behaviour 9},
doi = {10.1123/jmpb.2026-0037}
}Added to the ChatPPG research hub