Paperdoi:10.3390/s26206652

Sampling Frequency Requirements for Estimating Physical Activity Metrics from Wearable Accelerometer Data

Unconfirmed2026Added Oct 22, 2026

Licence: CC BY 4.0

TL;DR

315.4 h of labelled tri-axial ACC from 321 participants across 11 public datasets, harmonised to 50 Hz and anti-alias downsampled to 40/30/20/10/5 Hz. Compares MIMS, ENMO, Activity Index, dominant frequency and retained spectral power by activity and sensor location.

  • Form factor: any

Abstract

Accelerometers are widely used to quantify physical activity in population health research, yet the sampling frequency required to preserve commonly reported measures remains uncertain. We evaluated sampling frequency using 315.4 h of labelled tri-axial accelerometer data from 321 participants across 11 publicly available datasets. Signals were harmonized to a 50 Hz reference and downsampled to 40, 30, 20, 10, and 5 Hz using anti-aliased resampling. We compared Monitor-Independent Movement Summary (MIMS), Euclidean Norm Minus One (ENMO), Activity Index (AI), dominant spectral frequency, and retained spectral power across activities and sensor locations. For MIMS, 20 Hz remained within the prespecified 5% error margin for many walking, stair-climbing, cycling, jumping, household activities, and motorized-transportation conditions, whereas running exceeded this margin at 20 Hz at lower-limb and trunk locations. At 10 Hz, errors increased for most ambulatory activities, and only about 60–72% of reference spectral power was retained for walking and running, despite preservation of their dominant movement frequencies. MIMS error was not associated with age, sex/gender, or BMI, although small sex/gender associations were observed for ENMO and AI. Sampling-frequency requirements, therefore, depend on the metric, activity, and sensor location, supporting fit-for-purpose selection rather than use of a single universal sampling rate.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Activity recognition

Signals

Keywords

accelerometersampling-rateMIMSENMOactivity-indexdownsamplingphysical-activitysensor-locationpower-budget

How it works

How Method works: Setup → Method → TargetSetup: Signals (imu); Form factor (any). Method: Method. Target: Activity recognition.SetupSignals: imuxyzSignalsimuForm factor: anyForm factoranyMethodMethodTargetActivity recognitionActivity recognition

Cite this paper

APA

Sampling Frequency Requirements for Estimating Physical Activity Metrics from Wearable Accelerometer Data. (2026). https://doi.org/10.3390/s26206652

BibTeX

@misc{straczkiewiczacc2026sampling,
  title         = {{Sampling Frequency Requirements for Estimating Physical Activity Metrics from Wearable Accelerometer Data}},
  year          = {2026},
  doi           = {10.3390/s26206652}
}

Built from the hub record. Check it against the publisher before submitting.