Key results
All results- Beat-synchronous tokenization (Tok1)Table 1 (source, opens in a new tab)
0.8945
AUROC ↑
ECG diagnosis · PTB-XL (5 superclasses)
5 diagnostic superclasses, macro AUROC · transformer pretrained on MIMIC-IV-ECG, evaluated on PTB-XL
Results as reported by the authors; not independently reproduced. A SOTA star marks the best value among results reported under the same evaluation protocol; ties go to the earlier publication.
TL;DR
University of Minnesota group asks a narrow, well-controlled question: does tokenizing an ECG waveform at cardiac-cycle (beat) boundaries instead of fixed time patches change Transformer performance, holding everything else (encoder architecture, SSL objective, evaluation protocol) constant? They compare fixed patches against three beat-synchronous tokenizer designs — resampled beats, adaptive-pooled beats, and resampled beats plus explicit R-R interval timing — on two settings: 12-lead diagnostic classification (PTB-XL after MIMIC-IV-ECG masked pretraining) and single-lead rhythm classification (Icentia11k after patient-level contrastive pretraining). No wrist signal, no PPG, no accelerometer — this is a pure ECG tokenization ablation.
Abstract
Transformer-based electrocardiogram (ECG) models commonly tokenize waveforms into fixed temporal patches. Though convenient, fixed patching can split heartbeat structures across token boundaries. We study beat-synchronous tokenization as a physiologically grounded alternative, comparing fixed patches with three beat-aligned strategies: resampled beats, adaptive pooled beats, and resampled beats augmented with R–R interval information. Experiments span two settings: 10-second 12-lead diagnostic classification on PTB-XL after MIMIC-IV-ECG masked pretraining, and 60-second single-lead rhythm classification on Icentia11k after patient-level contrastive pretraining. On PTB-XL, resampled beat tokens achieve the highest mean macro Area Under the ROC Curve (AUROC; 0.8945) and nearly match the best fixed-patch macro Area Under the Precision-Recall Curve (AUPRC; 0.7414), reducing average sequence length from 100 to 11.2 tokens. On Icentia11k, beat-synchronous tokenizers obtain comparable AUPRC to fixed patching with better stability across runs. These results suggest morphology-preserving beat tokenization is a compact, competitive alternative to fixed temporal patching.
Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
Datasets used
Models
How it works
Cite this paper
Beat-Synchronous Tokenization for ECG Transformers. (2026). IEEE MLSP 2026. https://doi.org/10.48550/arXiv.2608.30367
@article{beatsynchronouse2026beatsynchronous,
title = {{Beat-Synchronous Tokenization for ECG Transformers}},
year = {2026},
journal = {IEEE MLSP 2026},
doi = {10.48550/arXiv.2608.30367},
eprint = {2608.30367},
archivePrefix = {arXiv}
}Record updated