Dataset

SensSmartTech

ECG+PCG+dual-λ PPG+ACC polycardiograph (n=32, 338×30s)

SensSmartTech (Lazović et al.; PhysioNet v1.0.0, published 2024-12-19). First multisensory base systematically following heart relaxation dynamics across a wide HR range. CSV = original rates; WFDB = resampled to 1 kHz common axis.

At a glance
Type
Dataset
Licence
Not reported
Access
Not reported
Subjects
32
PPG sites
Other
Setting
Lab
Wrist
No
Raw waveforms
Yes
Updated
Nov 16, 2026

Original description

The SensSmartTech database comprises cardiovascular signals synchronously recorded by electrocardiograph (ECG), phonocardiograph (PCG), photoplethysmograph (PPG) and accelerometer (ACC) at heart rates at rest and after activity (HRs). It is composed of 338 30-s recordings taken from 32 healthy volunteers. Recordings contain information from 10 channels: 4 ECG (limb, V3 and V4 leads), 1 PCG (measured at heart apex), 4 PPG (measured at carotid and brachial arteries at two light wavelengths each) and 1 ACC (measured between V3 and V4 ECG electrodes), along with the recording time of each signal. The original recordings are stored in CSV format. Resampled recordings are stored in WFDB format. The large HR range with the average minimum on the set of 83 ± 11 bpm and the average maximum on the set of 143 ± 14 bpm, along with several recordings per heart relaxation period, enable studying of the cardiovascular dynamics and gaining insights into the corresponding cardio-respiratory and electro-mechanical couplings. Of particular clinical significance are the opportunities to derive corrections of multiparameter biomarkers for HR.

Verbatim fromPhysioNet· Licence: Creative Commons Attribution 4.0 International Public License

SensSmartTech: ChatPPG research summary card

Key numbers

32
Subjects
3
Reference labels
CUFF BP, RESP RATE, SQI
1 kHz
Released sampling rate
PPG 100 Hz (carotid+brachial × 660/800 nm); ECG 500 Hz (4 leads); PCG 1 kHz; ACC (chest z) per MPU6050; WFDB resampled to 1 kHz common axis

How it works

How SensSmartTech works: Devices & body sites → Signals recorded → TasksDevices & body sites: Maxim MAX86150 (Maxim Integrated / Analog Devices · Multi site). PPG sites: Other. Signals recorded: SensSmartTech, 32 subjects · 1 kHz, signals PPG, ECG, IMU, Audio. Tasks: Blood pressure; Signal quality.Devices & body sitesMaxim MAX86150: Maxim Integrated / Analog Devices · Multi siteMaxim MAX86150Maxim Integrated / Analog Devices ·…PPG sites: OtherPPG sitesOtherSignals recordedSensSmartTech32 subjects · 1 kHzPPGECGxyzIMUAudioTasksBlood pressureBlood pressureSignal qualitySignal quality

No model in the hub reports results on this dataset yet.

Sampling
PPG 100 Hz (carotid+brachial × 660/800 nm); ECG 500 Hz (4 leads); PCG 1 kHz; ACC (chest z) per MPU6050; WFDB resampled to 1 kHz common axis
Reference labels
cuff bp, resp rate, sqi
Device roles
Clinical reference (ECG) · Study wearable (IMU) · Clinical reference (BP)

Devices· 1

Icons show the form factor: we have no openly licensed or manufacturer-cleared photo of these exact devices yet.

Papers using this dataset· 1

#131 of 186 most-used datasets by published papers and models · #65 of 88 PPG · #59 of 78 ECG · #59 of 84 IMU

FAQ

How many subjects are in SensSmartTech?

SensSmartTech has data from 32 subjects, as listed in its research record.

What signals does SensSmartTech include?

SensSmartTech includes PPG, ECG, accelerometer and phonocardiogram (PCG) data. Sampling rate as recorded: PPG 100 Hz (carotid+brachial × 660/800 nm); ECG 500 Hz (4 leads); PCG 1 kHz; ACC (chest z) per MPU6050; WFDB resampled to 1 kHz common axis. Raw waveforms are included.

What can SensSmartTech be used for?

Research tasks it supports: cuffless blood pressure estimation and motion and signal quality. Reference labels: cuff blood pressure, resp rate and signal quality.

How do I get SensSmartTech, and what is its licence?

It is hosted on PhysioNet at https://physionet.org/content/senssmarttech/1.0.0/. No licence is recorded for it here, so check the terms on the source page before you use it.

Cite this dataset

Cite this dataset with the fields recorded here. Check it against the publisher before submitting.

SensSmartTech [Data set]. (n.d.). physionet. https://doi.org/10.13026/fy9p-n277
@misc{senssmarttechsenssmarttech,
  title         = {{SensSmartTech}},
  howpublished  = {physionet},
  doi           = {10.13026/fy9p-n277}
}

Cite the ChatPPG record

Cite the dated snapshot 2026-10 for a fixed, reproducible version. Please also cite the original publications listed above.

APA

ChatPPG. (2026). SensSmartTech: dataset record (Version 2026-10) [Data set]. ChatPPG Research Hub. https://chatppg.com/research/datasets/senssmarttech

BibTeX
@misc{chatppg_dataset_senssmarttech,
  author       = {{ChatPPG}},
  title        = {{SensSmartTech: dataset record}},
  year         = {2026},
  month        = nov,
  version      = {2026-10},
  howpublished = {\url{https://chatppg.com/research/datasets/senssmarttech}},
  note         = {ChatPPG Research Hub, Snapshot 2026-10, https://chatppg.com/research/snapshots/2026-10}
}
CITATION.cff
cff-version: 1.2.0
message: "If you use this resource, please cite it as below."
type: dataset
title: "SensSmartTech: dataset record"
authors:
  - name: "ChatPPG"
url: "https://chatppg.com/research/datasets/senssmarttech"
repository-artifact: "https://chatppg.com/research/snapshots/2026-10"
version: "2026-10"
date-released: "2026-11-16"

History