Cite this dataset
SensSmartTech [Data set]. (n.d.). physionet. https://doi.org/10.13026/fy9p-n277
@misc{senssmarttechsenssmarttech,
title = {{SensSmartTech}},
howpublished = {physionet},
doi = {10.13026/fy9p-n277}
}SensSmartTech (Lazović et al.; PhysioNet v1.0.0, published 2024-12-19). First multisensory base systematically following heart relaxation dynamics across a wide HR range. CSV = original rates; WFDB = resampled to 1 kHz common axis.
The SensSmartTech database comprises cardiovascular signals synchronously recorded by electrocardiograph (ECG), phonocardiograph (PCG), photoplethysmograph (PPG) and accelerometer (ACC) at heart rates at rest and after activity (HRs). It is composed of 338 30-s recordings taken from 32 healthy volunteers. Recordings contain information from 10 channels: 4 ECG (limb, V3 and V4 leads), 1 PCG (measured at heart apex), 4 PPG (measured at carotid and brachial arteries at two light wavelengths each) and 1 ACC (measured between V3 and V4 ECG electrodes), along with the recording time of each signal. The original recordings are stored in CSV format. Resampled recordings are stored in WFDB format. The large HR range with the average minimum on the set of 83 ± 11 bpm and the average maximum on the set of 143 ± 14 bpm, along with several recordings per heart relaxation period, enable studying of the cardiovascular dynamics and gaining insights into the corresponding cardio-respiratory and electro-mechanical couplings. Of particular clinical significance are the opportunities to derive corrections of multiparameter biomarkers for HR.
Verbatim fromPhysioNet· Licence: Creative Commons Attribution 4.0 International Public License

No model in the hub reports results on this dataset yet.
Icons show the form factor: we have no openly licensed or manufacturer-cleared photo of these exact devices yet.
#131 of 186 most-used datasets by published papers and models · #65 of 88 PPG · #59 of 78 ECG · #59 of 84 IMU
SensSmartTech has data from 32 subjects, as listed in its research record.
SensSmartTech includes PPG, ECG, accelerometer and phonocardiogram (PCG) data. Sampling rate as recorded: PPG 100 Hz (carotid+brachial × 660/800 nm); ECG 500 Hz (4 leads); PCG 1 kHz; ACC (chest z) per MPU6050; WFDB resampled to 1 kHz common axis. Raw waveforms are included.
Research tasks it supports: cuffless blood pressure estimation and motion and signal quality. Reference labels: cuff blood pressure, resp rate and signal quality.
It is hosted on PhysioNet at https://physionet.org/content/senssmarttech/1.0.0/. No licence is recorded for it here, so check the terms on the source page before you use it.
SensSmartTech [Data set]. (n.d.). physionet. https://doi.org/10.13026/fy9p-n277
@misc{senssmarttechsenssmarttech,
title = {{SensSmartTech}},
howpublished = {physionet},
doi = {10.13026/fy9p-n277}
}Cite the dated snapshot 2026-10 for a fixed, reproducible version. Please also cite the original publications listed above.
ChatPPG. (2026). SensSmartTech: dataset record (Version 2026-10) [Data set]. ChatPPG Research Hub. https://chatppg.com/research/datasets/senssmarttech
@misc{chatppg_dataset_senssmarttech,
author = {{ChatPPG}},
title = {{SensSmartTech: dataset record}},
year = {2026},
month = nov,
version = {2026-10},
howpublished = {\url{https://chatppg.com/research/datasets/senssmarttech}},
note = {ChatPPG Research Hub, Snapshot 2026-10, https://chatppg.com/research/snapshots/2026-10}
}cff-version: 1.2.0 message: "If you use this resource, please cite it as below." type: dataset title: "SensSmartTech: dataset record" authors: - name: "ChatPPG" url: "https://chatppg.com/research/datasets/senssmarttech" repository-artifact: "https://chatppg.com/research/snapshots/2026-10" version: "2026-10" date-released: "2026-11-16"
Record updated