Dataset

Radboud PTT PPG+BP (Mol 2020)

wrist+finger PPG with Finapres BP

Official title: Pulse transit time as a proxy for vasoconstriction in younger and older adults (version 1). Creators: Arjen Mol, Carel G.M. Meskers, Sjoerd P.

At a glance
Type
Dataset
Licence
Not reported
Access
Not reported
Subjects
86
PPG sites
WristFinger
Setting
Lab
Wrist
Yes
Raw waveforms
Yes
Updated
Nov 13, 2026

Original description

Objectives: Changes of vasoconstriction may be measured non-invasively using pulse transit time. This study assessed the sensitivity, test-retest reliability and validity of pulse transit time during vasoconstriction provocation and active standing, and the predictive value of pulse transit time for blood pressure drop. Methods: Fifty-five younger (age 70 years) underwent electrocardiography, wrist and finger photoplethysmography and continuous blood pressure and total peripheral resistance measurements during vasoconstriction provocation using a cold pressor test (21 younger adults), or active stand tests (all other participants). Pulse transit time was defined as the time lag between the electrocardiography R-peak and the peak in the photoplethysmography first derivative; sensitivity as a significant decrease relative to baseline; test-retest reliability as the intra class correlation between different repeats of the same test; validity as the association between total peripheral resistance and pulse transit time; predictive value as the association between supine resting pulse transit time and mean arterial pressure drop during active standing. Results: Finger pulse transit time was sensitive and reliable (ICC 0.2-0.8) during vasoconstriction provocation, but wrist pulse transit time was poorly reliable (ICC 0 – 0.5); only finger pulse transit time was sensitive to and reliable (ICC 0.4 – 0.8) during active standing in both younger and older adults. Finger pulse transit time was not associated with total peripheral resistance. Supine resting pulse transit time had predictive value for blood pressure drop during active standing in older adults (β -0.16; p 0.025). Conclusions: Pulse transit time was sensitive to and reliable during vasoconstriction provocation and active standing, but did not significantly differ between younger and older adults. Pulse transit time could not be demonstrated to particularly reflect vasoconstriction, but it had predictive value for blood pressure drop during active standing.

Verbatim fromDataCite· Licence: info:eu-repo/semantics/restrictedAccess

Radboud PTT PPG+BP (Mol 2020): ChatPPG research summary card

Key numbers

86
Subjects
1
Reference labels
BP
50 Hz
Released sampling rate
custom PPG raw ~989 Hz (fs_s=970 in metadata), preprocessed 1000 Hz; Finapres NOVA ~200 Hz (fs_fp=197); ECG ~333 Hz; SpO2 pleth ~77 Hz (not the custom PPG); NIRS 50 Hz

How it works

How Radboud PTT PPG+BP (Mol 2020) works: Devices & body sites → Signals recorded → TasksDevices & body sites: Finapres NOVA (Finapres Medical Systems · Finger). PPG sites: Wrist, Finger. Signals recorded: Radboud PTT PPG+BP (Mol 2020), 86 subjects · 50 Hz, signals PPG, ECG, SpO₂, ABP, Respiration, Temperature. Tasks: Blood pressure; Panic sympathetic arousal; Sympathetic arousal.Devices & body sitesFinapres NOVA: Finapres Medical Systems · FingerFinapres NOVAFinapres Medical Systems · FingerPPG sites: Wrist, FingerPPG sitesWrist, FingerSignals recordedRadboud PTT PPG+BP (Mol 2020)86 subjects · 50 HzPPGECGR / IRSpO₂ABPRespirationTemperatureTasksBlood pressureBlood pressurePanic sympathetic arousalPanic sympathetic arousalSympathetic arousalSympathetic arousal

No model in the hub reports results on this dataset yet.

Sampling
custom PPG raw ~989 Hz (fs_s=970 in metadata), preprocessed 1000 Hz; Finapres NOVA ~200 Hz (fs_fp=197); ECG ~333 Hz; SpO2 pleth ~77 Hz (not the custom PPG); NIRS 50 Hz
Reference labels
bp
Device roles
Clinical reference (BP) · Clinical reference (ECG)

Devices· 1

Full photo credits, sources and licences are on each device page.

FAQ

How many subjects are in Radboud PTT PPG+BP?

Radboud PTT PPG+BP has data from 86 subjects, as listed in its research record.

What signals does Radboud PTT PPG+BP include?

Radboud PTT PPG+BP includes PPG, ECG, continuous blood pressure, total peripheral resistance (TPR), NIRS, SpO2 and respiration data. Sampling rate as recorded: custom PPG raw ~989 Hz (fs_s=970 in metadata), preprocessed 1000 Hz; Finapres NOVA ~200 Hz (fs_fp=197); ECG ~333 Hz; SpO2 pleth ~77 Hz (not the custom PPG); NIRS 50 Hz. Raw waveforms are included.

What can Radboud PTT PPG+BP be used for?

Research tasks it supports: cuffless blood pressure estimation. Reference labels: blood pressure.

How do I get Radboud PTT PPG+BP, and what is its licence?

It is available from https://data.ru.nl/collections/di/dcn/DSC_626810_0007_173. No licence is recorded for it here, so check the terms on the source page before you use it.

Cite this dataset

Cite this dataset with the fields recorded here. Check it against the publisher before submitting.

Radboud PTT PPG+BP (Mol 2020) [Data set]. (n.d.). radboud-data-repository. https://doi.org/10.34973/te70-x603
@misc{radboudpttppgbpradboud,
  title         = {{Radboud PTT PPG+BP (Mol 2020)}},
  howpublished  = {radboud-data-repository},
  doi           = {10.34973/te70-x603}
}

Cite the ChatPPG record

Cite the dated snapshot 2026-10 for a fixed, reproducible version. Please also cite the original publications listed above.

APA

ChatPPG. (2026). Radboud PTT PPG+BP (Mol 2020): dataset record (Version 2026-10) [Data set]. ChatPPG Research Hub. https://chatppg.com/research/datasets/radboud-ptt-ppg-bp

BibTeX
@misc{chatppg_dataset_radboud_ptt_ppg_bp,
  author       = {{ChatPPG}},
  title        = {{Radboud PTT PPG+BP (Mol 2020): dataset record}},
  year         = {2026},
  month        = nov,
  version      = {2026-10},
  howpublished = {\url{https://chatppg.com/research/datasets/radboud-ptt-ppg-bp}},
  note         = {ChatPPG Research Hub, Snapshot 2026-10, https://chatppg.com/research/snapshots/2026-10}
}
CITATION.cff
cff-version: 1.2.0
message: "If you use this resource, please cite it as below."
type: dataset
title: "Radboud PTT PPG+BP (Mol 2020): dataset record"
authors:
  - name: "ChatPPG"
url: "https://chatppg.com/research/datasets/radboud-ptt-ppg-bp"
repository-artifact: "https://chatppg.com/research/snapshots/2026-10"
version: "2026-10"
date-released: "2026-11-13"

History

  1. Record updated