PaperarXiv:2608.23276
A Multidimensional Data-Driven Hybrid Transformer Framework for Non-invasive Continuous Blood Pressure Prediction
arXiv preprint
TL;DR
Models 10-step sequences of 8 engineered features (PTT, HR, PPG morphology, age, weight) — not raw waveforms — with Multi-Source Temporal Encoder (Transformer + KAN + XGBoost) and Dynamic Conditional Fusion-Decoder. MIMIC-III waveforms + clinical linkage. Held-out (segment-level, not subject-disjoint) ME±SD: DBP 0.41±3.74, SBP −1.60±5.95 mmHg; authors note numerical AAMI/BHS Grade A thresholds on this split but explicitly warn this is not formal device validation and subject-disjoint/external eval remains needed.
- Form factor: lab
Abstract
Objective. To develop and evaluate a cuffless continuous blood pressure (BP) estimator using temporal physiological and demographic features. We propose a hybrid Transformer framework to estimate diastolic and systolic BP from ECG/PPG-derived feature sequences. Approach. Rather than raw waveforms, the framework models 10-step sequences of six physiological descriptors and two demographic covariates. A Multi-Source Temporal Encoder Module combines Transformer, Kolmogorov-Arnold Network, and XGBoost branches to capture complementary temporal, nonlinear, and tabular information. A Dynamic Conditional Fusion-Decoder applies differential multi-head attention, token-weighted aggregation, and gated residual correction. A robust composite objective jointly optimizes DBP and SBP. Main results. Using the MIMIC-III Waveform and Clinical Databases, the source pool comprised 28,486 waveform segments from 203 subjects, and feature generation retained 53,621 observations from 166 subjects. On 2,431 segment-level held-out test windows, mean error +/- standard deviation was 0.41 +/- 3.74 mmHg for diastolic BP and -1.60 +/- 5.95 mmHg for systolic BP, with 95% limits of agreement of [-6.93, 7.74] and [-13.25, 10.06] mmHg, respectively. The proportions within 10 mmHg were 98.48% and 94.36%. The framework achieved the lowest standard deviations and narrowest limits of agreement among the locally retrained baselines. Significance. The feature-sequence fusion framework improved agreement with reference BP and fell within numerical AAMI and BHS Grade A thresholds on this split. This retrospective analysis is not formal device validation; subject-disjoint and external evaluation remain necessary before clinical use.
Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
How it works
Cite this paper
APA
Ma, Y., Hou, J., Kang, Y., & Liu, Z. (2026). A Multidimensional Data-Driven Hybrid Transformer Framework for Non-invasive Continuous Blood Pressure Prediction. arXiv preprint. https://arxiv.org/abs/2608.23276
BibTeX
@misc{ma2026multidimensional,
title = {{A Multidimensional Data-Driven Hybrid Transformer Framework for Non-invasive Continuous Blood Pressure Prediction}},
author = {Ma, Yuexin and Hou, Jingqi and Kang, Yuxuan and Liu, Zhaoying},
year = {2026},
howpublished = {arXiv preprint},
eprint = {2608.23276},
archivePrefix = {arXiv}
}Built from the hub record. Check it against the publisher before submitting.
Added to the ChatPPG research hub