Flexible Ultrasound Transducers for Continuous Blood Pressure Monitoring: A Review of Wearable Architectures, Blood Pressure Inference, and Clinical Translation

Venue listed2026Added Nov 25, 2026

  • SZ
  • YL
  • SH

Authors: Syed Turab Haider Zaidi, Young Jin Lee, Shin Hur

Sensors 26(23):7442, published 2026-11-25 (review)

TL;DR

Reviews flexible/wearable ultrasound BP from a data-generation and inference perspective: BP is inferred from arterial wall displacement, diameter change, PWV and flow features, not measured directly. Covers transducer materials (piezo composites, polymer transducers, micromachined arrays), structural design and coupling, and how these affect signal stability during motion and long wear. Groups inference into diameter-, timing-, waveform- and hybrid-based approaches, with coupling variability, motion artefacts, calibration requirements and wearability as the limits.

  • Form factor: other

Abstract

Wearable ultrasound transducers offer a promising approach to cuffless, continuous blood pressure (BP) monitoring by measuring vascular structures and dynamics during on-body use. BP is inferred from arterial wall displacement, diameter changes, pulse wave velocity, and flow-related features rather than measured directly. This review examines flexible and wearable ultrasound technologies from a data generation and inference perspective, using BP monitoring as a representative application. It evaluates how transducer materials, structural designs, and coupling strategies affect signal stability and interpretation during motion and prolonged wear. Flexible piezoelectric composites, polymer-based transducers, and micromachined arrays are considered in terms of acoustic performance, mechanical compliance, and reliable arterial interrogation. The review highlights that BP estimation accuracy depends jointly on device architecture, vascular observables, physiological variability, and inference models. Diameter-, timing-, waveform-, and hybrid-based approaches are discussed alongside coupling variability, motion artifacts, calibration requirements, and long-term wearability. Although reported advances demonstrate commercial potential, clinical translation requires standardized assessment of accuracy, calibration stability, and performance under intended conditions of use. The review also examines validation requirements relevant to commercialization, distinguishing BP performance evaluation from ultrasound equipment safety and essential performance. These considerations identify priorities for developing clinically validated wearable ultrasound BP monitoring systems for sustained use.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Blood pressure

Signals

Keywords

Cuffless BPReviewWearable UltrasoundArterial DiameterPWVCalibrationValidationRegulatory

How it works

How Method works: Setup → Method → TargetSetup: Signals (ultrasound); Form factor (other). Method: Method. Target: Blood pressure.SetupSignals: ultrasoundSignalsultrasoundForm factor: otherForm factorotherMethodMethodTargetBlood pressureBlood pressure

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Zaidi, S. T. H., Lee, Y. J., & Hur, S. (2026). Flexible Ultrasound Transducers for Continuous Blood Pressure Monitoring: A Review of Wearable Architectures, Blood Pressure Inference, and Clinical Translation. Sensors, 26(23), 7442. https://doi.org/10.3390/s26237442
Zaidi, Syed Turab Haider, Young Jin Lee, and Shin Hur. 2026. "Flexible Ultrasound Transducers for Continuous Blood Pressure Monitoring: A Review of Wearable Architectures, Blood Pressure Inference, and Clinical Translation." Sensors 26 (23): 7442. https://doi.org/10.3390/s26237442.
Zaidi, S. T. H., Lee, Y. J. and Hur, S. (2026) 'Flexible Ultrasound Transducers for Continuous Blood Pressure Monitoring: A Review of Wearable Architectures, Blood Pressure Inference, and Clinical Translation', Sensors, 26(23), p. 7442. doi: 10.3390/s26237442.
Zaidi, Syed Turab Haider, et al. "Flexible Ultrasound Transducers for Continuous Blood Pressure Monitoring: A Review of Wearable Architectures, Blood Pressure Inference, and Clinical Translation." Sensors, vol. 26, no. 23, 2026, p. 7442. https://doi.org/10.3390/s26237442.
S. T. H. Zaidi, Y. J. Lee, and S. Hur, "Flexible Ultrasound Transducers for Continuous Blood Pressure Monitoring: A Review of Wearable Architectures, Blood Pressure Inference, and Clinical Translation," Sensors, vol. 26, no. 23, p. 7442, 2026, doi: 10.3390/s26237442.
@article{zaidi2026flexible,
  title         = {{Flexible Ultrasound Transducers for Continuous Blood Pressure Monitoring: A Review of Wearable Architectures, Blood Pressure Inference, and Clinical Translation}},
  author        = {Zaidi, Syed Turab Haider and Lee, Young Jin and Hur, Shin},
  year          = {2026},
  journal       = {Sensors},
  volume        = {26},
  number        = {23},
  pages         = {7442},
  doi           = {10.3390/s26237442}
}

Added to the ChatPPG research hub