Paperdoi:10.1159/pls/aeoag005
Ring-based cuffless BP: at the crossroads of innovation and clinical reality (Sung, Pulse 2026)
Pulse (Karger), 2026-10-05
TL;DR
A narrative review. Ring devices estimate BP from PPG and pulse-wave features but do not measure arterial pressure directly. Accuracy depends on physiological variability, calibration and population heterogeneity.
- Form factor: ring
Abstract
Background: Cuffless wearable technologies for blood pressure (BP) monitoring have emerged as a promising alternative to conventional cuff-based methods, offering the possibility of continuous, real-world assessment. Summary: Ring-based devices estimate BP from peripheral signals, including photoplethysmography and pulse wave features. Although early studies have shown encouraging correlations with reference standards, these systems do not directly measure arterial pressure. Their performance is affected by physiological variability, calibration dependence, and population heterogeneity. Current evidence suggests that these devices may provide useful information about BP dynamics, but their accuracy and reliability remain insufficient for routine clinical decision-making. Key Messages: Cuffless BP monitoring represents an important technological advance, but it remains constrained by fundamental methodological challenges. Broader validation in diverse populations and outcome-based clinical trials are needed before widespread clinical adoption.
Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
How it works
Cite this paper
Sung, K.-C. (2026). Ring-based cuffless BP: at the crossroads of innovation and clinical reality (Sung, Pulse 2026). Pulse. https://doi.org/10.1159/pls/aeoag005
Sung, Ki-Chul. 2026. "Ring-based cuffless BP: at the crossroads of innovation and clinical reality (Sung, Pulse 2026)." Pulse. https://doi.org/10.1159/pls/aeoag005.
Sung, K.-C. (2026) 'Ring-based cuffless BP: at the crossroads of innovation and clinical reality (Sung, Pulse 2026)', Pulse. doi: 10.1159/pls/aeoag005.
Sung, Ki-Chul "Ring-based cuffless BP: at the crossroads of innovation and clinical reality (Sung, Pulse 2026)." Pulse, 2026. https://doi.org/10.1159/pls/aeoag005.
K.-C. Sung, "Ring-based cuffless BP: at the crossroads of innovation and clinical reality (Sung, Pulse 2026)," Pulse, 2026, doi: 10.1159/pls/aeoag005.
@article{sung2026ringbased,
title = {{Ring-based cuffless BP: at the crossroads of innovation and clinical reality (Sung, Pulse 2026)}},
author = {Sung, Ki-Chul},
year = {2026},
journal = {Pulse},
publisher = {Karger},
doi = {10.1159/pls/aeoag005}
}Added to the ChatPPG research hub