Foundation model

AI-PPG-ACC-HTN (Google Waveform Encoder + HTN probe)

Venue listedCatalog paper date: 2025Added to atlas: Nov 5, 2026Source

Activity counts measure attention, not model quality. Missing counts are unknown. Publication status follows the linked source; a listed venue alone does not confirm peer review.

Here the authors show that applying artificial intelligence (AI) to multimodal waveforms (photoplethysmography and accelerometry) recorded using a widely available consumer smartwatch (AI-PPG-ACC-HTN), without any cuff calibration, can detect hypertension with accuracy levels comparable to traditional cuffed blood pressure (BP) devices in the existing clinical framework. The authors validated AI-PPG-ACC-HTN in a prospective, multicenter study of 196 diverse participants free from known cardiovascular disease and antihypertensive medication against gold-standard 24-hour ambulatory BP monitoring. Over seven days of real-world monitoring, AI-PPG-ACC-HTN detected hypertension with a sensitivity of 65.8% (95% CI, 54.0%-76.3%), specificity of 90.0% (95% CI, 83.2%-94.7%), and positive predictive value (PPV) of 80.6% (95% CI, 68.6%-89.6%).

Published
Nature, 2026
Signals
PPG, IMU
Year
2025
Result

Over seven days of real-world monitoring, AI-PPG-ACC-HTN detected hypertension with a sensitivity of 65.8% (95% CI, 54.0%-76.3%), specificity of 90.0% (95% CI, 83.2%-94.7%), and positive predictive value (PPV) of 80.6% (95% CI, 68.6%-89.6%).

Result

In comparison, initial office BP screening achieved a sensitivity of 55.3% (95% CI, 43.4%-66.7%), specificity of 90.0% (95% CI, 83.2%-94.7%) and PPV of 77.8% (95% CI, 64.4%-88.0%).

At a glance
Type
Foundation model
Modalities
PPGIMU
Parameters
5.1M
Architecture
EfficientNet B1 1-D CNN Waveform Encoder (~5.1M params) → 256-d embedding from 15 s stacked green PPG + ACC magnitude; person-level mean aggregation (hour-of-day then user) + z-scored height → L2 logistic regression hypertension probe
Venue
Nature
Year
2025
arXiv
Not reported
Code
Not released
Weights
Not released
Licence
Not reported
Caveats
Not reported
Datasets
Not reported
Added
Nov 5, 2026
Updated
Nov 5, 2026
AI-PPG-ACC-HTN (Google Waveform Encoder + HTN probe): ChatPPG research summary card

Key results

0.658
sensitivity ↑ · Cuffless blood pressure
google-pixel-watch3-htn-abpm-196
#1 / 1
0.784
sensitivity ↑ · Cuffless blood pressure
google-pixel-watch3-htn-abpm-confirm-48
#1 / 1
65.8%
sensitivity
Over seven days of real-world monitoring, AI-PPG-ACC-HTN detected hypertension with a sensitivity of 65.8% (95% CI, 54.0%-76.3%), specifi…

How it works

How AI-PPG-ACC-HTN (Google Waveform Encoder + HTN probe) works: Input signals → Foundation model → Downstream tasksInput signals: PPG (Photoplethysmogram); IMU (Accelerometer, 3-axis). Foundation model: AI-PPG-ACC-HTN (Google Waveform Encoder + HTN probe), 5.1M parameters (Convolutional network). Downstream tasks: Blood pressure.Input signalsPPG: PhotoplethysmogramPPGPhotoplethysmogramIMU: Accelerometer, 3-axisxyzIMUAccelerometer, 3-axisFoundation modelAI-PPG-ACC-HTN (Google…5.1M parametersConvolutional networkDownstream tasksBlood pressureBlood pressure
Architecture
EfficientNet B1 1-D CNN Waveform Encoder (~5.1M params) → 256-d embedding from 15 s stacked green PPG + ACC magnitude; person-level mean aggregation (hour-of-day then user) + z-scored height → L2 logistic regression hypertension probe
Inputs
PPG, IMU
Approach
google · hypertension · cuffless bp · ppg acc · closed weights

Leaderboard rows· 2

All leaderboards
TaskDatasetMetricValueRank
Cuffless blood pressuregoogle-pixel-watch3-htn-abpm-196sensitivity ↑0.658#1 / 1
Cuffless blood pressuregoogle-pixel-watch3-htn-abpm-confirm-48sensitivity ↑0.784#1 / 1

Datasets used

No public datasets linked yet.

Papers· 2

Authors· 1

Cite this model

Cite the publication recorded for this model. Check it against the publisher before submitting.

Di Achille, P., Cai, L., Wu, J., Gao, M., Daryani, B., Wang, J., Khanna, U., Ko, H., Pathak, A., Malhotra, M., Patel, S., Shreibati, J. B., Juraschek, S. P., Rudrapatna, P., Thompson, M., & Poh, M.-Z. (2025). Opportunistically Detecting Signs of Hypertension on a Consumer Smartwatch (AI-PPG-ACC-HTN; Di Achille, Poh et al., Nature 2026). Nature. https://doi.org/10.1038/s41586-026-11336-3
Di Achille, Paolo, Lawrence Cai, Jiang Wu, Mingwu Gao, Bhavna Daryani, Jonathan Wang, and Utkarsh Khanna, et al. 2025. "Opportunistically Detecting Signs of Hypertension on a Consumer Smartwatch (AI-PPG-ACC-HTN; Di Achille, Poh et al., Nature 2026)." Nature. https://doi.org/10.1038/s41586-026-11336-3.
Di Achille, P., Cai, L., Wu, J., Gao, M., Daryani, B., Wang, J. and Khanna, U. et al. (2025) 'Opportunistically Detecting Signs of Hypertension on a Consumer Smartwatch (AI-PPG-ACC-HTN; Di Achille, Poh et al., Nature 2026)', Nature. doi: 10.1038/s41586-026-11336-3.
Di Achille, Paolo, et al. "Opportunistically Detecting Signs of Hypertension on a Consumer Smartwatch (AI-PPG-ACC-HTN; Di Achille, Poh et al., Nature 2026)." Nature, 2025. https://doi.org/10.1038/s41586-026-11336-3.
P. Di Achille et al., "Opportunistically Detecting Signs of Hypertension on a Consumer Smartwatch (AI-PPG-ACC-HTN; Di Achille, Poh et al., Nature 2026)," Nature, 2025, doi: 10.1038/s41586-026-11336-3.
@article{achille2025opportunistically,
  title         = {{Opportunistically Detecting Signs of Hypertension on a Consumer Smartwatch (AI-PPG-ACC-HTN; Di Achille, Poh et al., Nature 2026)}},
  author        = {Di Achille, Paolo and Cai, Lawrence and Wu, Jiang and Gao, Mingwu and Daryani, Bhavna and Wang, Jonathan and Khanna, Utkarsh and Ko, Ho and Pathak, Anupam and Malhotra, Mark and Patel, Shwetak and Shreibati, Jacqueline B. and Juraschek, Stephen P. and Rudrapatna, Pramod and Thompson, Matthew and Poh, Ming-Zher},
  year          = {2025},
  journal       = {Nature},
  doi           = {10.1038/s41586-026-11336-3}
}

History

  1. Added to the ChatPPG research hub