Paperdoi:10.2196/105647
Passive Monitoring for Detecting Hypomanic Symptoms in Bipolar Disorder Using Explainable Machine Learning: Longitudinal Observational Study
JMIR mHealth and uHealth (2026-11-18)
TL;DR
178 people with bipolar disorder wore a wearable for activity and sleep over a mean of 540 days. In the 43 who had at least one hypomanic interval (Altman self-rating), 252 time- and frequency-domain wearable features detected those intervals with AUROC 0.93 vs 0.91 for daily self-report, sensitivity 92.0% vs 85.4% and NPV 97.8%. Sleep features alone gave AUROC 0.91.
- Form factor: wearable (device not named in the abstract)
Abstract
Background
When trying to intervene early to prevent manic episodes, clinicians are hindered by patients underreporting their symptoms as they are becoming hypomanic or manic (ie, emerging symptoms). Continuous passive monitoring using wearable technology offers a potential solution to address this problem by capturing behavioral signals that do not depend on self-awareness. However, its clinical usefulness requires validation before implementation.
Objective
This study aimed to evaluate whether passively collected wearable data can detect hypomanic symptoms using an explainable machine learning framework.
Methods
We applied explainable machine learning to densely sampled multimodal data from a 2-year observational study of digital monitoring in 178 patients with a diagnosis of bipolar disorder (mean follow-up 540 days; range 120-706 days). Data on activity and sleep were collected continuously using wearable technology. Self-reported data were collected daily on their mood, energy, and anxiety, and weekly using the Altman Self-Rating Mania Scale (ASRM). To identify robust digital markers of hypomanic symptoms, we analyzed 252 time- and frequency-domain features from 43 participants who experienced at least 1 ASRM-defined symptomatic interval.
Results
Passively collected data achieved high accuracy, comparable with daily self-reported data in detecting symptomatic intervals (area under the receiver operating characteristic curve 0.91 vs 0.93, respectively). Combined daily passive wearable data features achieved higher sensitivity (92.0% vs 85.4%), balanced accuracy (0.90 vs 0.89), and stronger rule-out usefulness (negative predictive value 97.8% vs 96.1%) than self-report data, with daily sleep features alone driving most of this signal (area under the receiver operating characteristic curve 0.91, sensitivity 91.8%). The high classification performance using wearable data was explained by reductions in spectral entropy and flux across domains, reflecting a decreased complexity and variability in mood, activity, and sleep patterns, consistent with a shift toward pathologically stable states.
Conclusions
Passive monitoring using wearable technology can detect hypomanic symptoms with high accuracy, supporting its potential as a clinically meaningful tool for continuous, objective monitoring in patients who underreport hypomanic symptoms. These findings are associative and concurrent in nature; they do not establish predictive validity. Prospective studies are needed to evaluate predictive validity for early detection of ASRM-defined symptomatic intervals.
Verbatim from the publisher's DOI record (opens in a new tab) · Abstract as deposited by the publisher with Crossref; © the authors/publisher
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
How it works
Cite this paper
Halabi, R., Alda, M., Tolend, M., O’Donovan, C., Hintze, A., Mulsant, B. H., & Ortiz, A. (2026). Passive Monitoring for Detecting Hypomanic Symptoms in Bipolar Disorder Using Explainable Machine Learning: Longitudinal Observational Study. JMIR mHealth and uHealth. https://doi.org/10.2196/105647
Halabi, Ramzi, Martin Alda, Mirkamal Tolend, Claire O’Donovan, Arend Hintze, Benoit H. Mulsant, and Abigail Ortiz. 2026. "Passive Monitoring for Detecting Hypomanic Symptoms in Bipolar Disorder Using Explainable Machine Learning: Longitudinal Observational Study." JMIR mHealth and uHealth. https://doi.org/10.2196/105647.
Halabi, R., Alda, M., Tolend, M., O’Donovan, C., Hintze, A., Mulsant, B. H. and Ortiz, A. (2026) 'Passive Monitoring for Detecting Hypomanic Symptoms in Bipolar Disorder Using Explainable Machine Learning: Longitudinal Observational Study', JMIR mHealth and uHealth. doi: 10.2196/105647.
Halabi, Ramzi, et al. "Passive Monitoring for Detecting Hypomanic Symptoms in Bipolar Disorder Using Explainable Machine Learning: Longitudinal Observational Study." JMIR mHealth and uHealth, 2026. https://doi.org/10.2196/105647.
R. Halabi et al., "Passive Monitoring for Detecting Hypomanic Symptoms in Bipolar Disorder Using Explainable Machine Learning: Longitudinal Observational Study," JMIR mHealth and uHealth, 2026, doi: 10.2196/105647.
@article{halabi2026passive,
title = {{Passive Monitoring for Detecting Hypomanic Symptoms in Bipolar Disorder Using Explainable Machine Learning: Longitudinal Observational Study}},
author = {Halabi, Ramzi and Alda, Martin and Tolend, Mirkamal and O’Donovan, Claire and Hintze, Arend and Mulsant, Benoit H. and Ortiz, Abigail},
year = {2026},
journal = {JMIR mHealth and uHealth},
doi = {10.2196/105647}
}Added to the ChatPPG research hub