Paperdoi:10.3390/info17090878

Calibration-Based Cuffless Blood Pressure Estimation Using a Dilated-Residual Attention U-Net

Published articlePublished Sep 10, 2026Added Oct 11, 2026

  • TS
  • NT

Authors: Thomas Stogiannopoulos, Nikolaos Mitianoudis (Democritus University of Thrace)

Information (MDPI) 17(9):878

Key results

All results

Results as reported by the authors; not independently reproduced. A SOTA star marks the best value among results reported under the same evaluation protocol; ties go to the earlier publication.

TL;DR

Dual-stream 1D encoder-decoder on raw PPG + ECG: dilated residual convs, FiLM cross-signal modulation at the bottleneck, learned scale-wise fusion, attention-gated skips, mean-attention pooling head. PulseDB calibration-based subset (SBP 57–180, DBP 25–100 mmHg). MAE SBP 3.81 (ME −0.28 ± 5.54), DBP 2.03 (ME 0.38 ± 3.13), R² 0.92/0.93; BHS and IEEE-1708 grade A.

  • Form factor: clinical_finger

Abstract

Non-invasive blood pressure (BP) monitoring using photoplethysmography (PPG) has significant potential, yet accurately predicting systolic (SBP) and diastolic (DBP) blood pressure using photoplethysmogram (PPG) and electrocardiogram (ECG) signals remains challenging. This work proposes a novel dual-stream 1D encoder–decoder architecture for cuffless BP estimation from raw photoplethysmography (PPG) and electrocardiography (ECG) signals. The model incorporates multi-scale temporal feature extraction via dilated residual convolutions, cross-signal feature modulation at the bottleneck using Feature-wise Linear Modulation (FiLM), learned scale-wise fusion across encoder levels, attention-gated skip connections, and a hybrid mean-attention pooling regression head. Evaluated under calibration-based conditions on the PulseDB dataset (with selected data values of SBP ∈ [57, 180] mmHg and DBP ∈ [25, 100]), the proposed model achieved a mean absolute error (MAE) of 2.03 mmHg, mean error (ME) of 0.38 ± 3.13 mmHg, and an R2 of 0.93 for diastolic BP (DBP) and an MAE of 3.81 mmHg, ME of −0.28 ± 5.54 mmHg, and an R2 of 0.92 for systolic BP (SBP). The results meet the British Hypertension Society (BHS) and IEEE-1708 standard and achieved an “A” Grade. ECG alone provides lower prediction errors than PPG alone under the evaluated conditions, while their combination yields the best performance. Gender- and age-stratified analyses reveal consistent model behavior across demographic subgroups, with prediction error increasing modestly in older cohorts, particularly among women. This study provides an accurate, calibration-based, cuffless BP estimation and highlights its potential for non-invasive BP monitoring applications.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/

Results on ChatPPG leaderboards · 1

All leaderboards
LeaderboardMethodResultRank
pulsedb-calbased MAE (mmHg)Cuffless blood pressure estimationDilated-residual attention U-Net3.81MAE (mmHg), lower is better#1 of 2

1 row is credited to this paper. Ranks apply within each leaderboard only, as reported by the source.

Tasks & signals

Signals

Keywords

Cuffless BPPulseDBCalibration BasedU NetFiLMPPG+ECG

Datasets used

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG, ECG); Form factor (clinical_finger). Method: Method (Convolutional network). Target: Blood pressure.SetupSignals: PPG, ECGSignalsPPG, ECGForm factor: clinical_fingerForm factorclinical_fingerMethodMethodConvolutional networkTargetBlood pressureBlood pressure

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Stogiannopoulos, T., & Mitianoudis, N. (2026). Calibration-Based Cuffless Blood Pressure Estimation Using a Dilated-Residual Attention U-Net. Information, 17(9), 878. https://doi.org/10.3390/info17090878
Stogiannopoulos, Thomas and Nikolaos Mitianoudis. 2026. "Calibration-Based Cuffless Blood Pressure Estimation Using a Dilated-Residual Attention U-Net." Information 17 (9): 878. https://doi.org/10.3390/info17090878.
Stogiannopoulos, T. and Mitianoudis, N. (2026) 'Calibration-Based Cuffless Blood Pressure Estimation Using a Dilated-Residual Attention U-Net', Information, 17(9), p. 878. doi: 10.3390/info17090878.
Stogiannopoulos, Thomas, and Nikolaos Mitianoudis "Calibration-Based Cuffless Blood Pressure Estimation Using a Dilated-Residual Attention U-Net." Information, vol. 17, no. 9, 2026, p. 878. https://doi.org/10.3390/info17090878.
T. Stogiannopoulos and N. Mitianoudis, "Calibration-Based Cuffless Blood Pressure Estimation Using a Dilated-Residual Attention U-Net," Information, vol. 17, no. 9, p. 878, 2026, doi: 10.3390/info17090878.
@article{stogiannopoulos2026calibrationbased,
  title         = {{Calibration-Based Cuffless Blood Pressure Estimation Using a Dilated-Residual Attention U-Net}},
  author        = {Stogiannopoulos, Thomas and Mitianoudis, Nikolaos},
  year          = {2026},
  journal       = {Information},
  volume        = {17},
  number        = {9},
  pages         = {878},
  publisher     = {MDPI},
  doi           = {10.3390/info17090878}
}

Added to the ChatPPG research hub