The role of dataset integrity, calibration and signal quality in neural network-based blood pressure estimation
Activity counts measure attention, not model quality. Missing counts are unknown. Publication status follows the linked source; a listed venue alone does not confirm peer review.
MLP (PAT/HR/HRV scalars), ResNet and TCN on curated MIMIC-III and VitalDB sets that differ mainly in signal synchronization; subject-wise splits; calibration with 3–9 initial reference readings. VitalDB-trained models beat MIMIC-III ones (synchronization matters, especially for SBP). Calibration helps, with diminishing returns after 3 readings.
- Venue: Scientific Reports
- Signals: PPG, ECG
- Form factor: clinical_finger
- Venue
- Scientific Reports
- Published
- 2026
- arXiv
- Not reported
- PMID
- Not reported
- Licence
- Not reported
- Form factor
- Clinical finger
- Datasets
- Subjects
- Not reported
- Code
- Not reported
- Added
- Oct 11, 2026
Abstract
Cuffless blood pressure (BP) estimation via photoplethysmography (PPG) and machine learning has been widely studied, yet reported accuracy remains below clinically acceptable levels, limiting adoption in sport, ambient living, and telemedicine. This study systematically examines potential error sources underlying these performance gaps, with emphasis on: dataset selection, signal synchronization, subject-specific calibration, and data leakage. Three neural networks—a multilayer perceptron (MLP_BP), residual network (Res_BP), and temporal convolutional network (TCN_BP)—were evaluated on two curated public datasets derived from MIMIC III and VitalDB, differing primarily in signal synchronization. MLP_BP uses scalar features from ECG and PPG signals, including pulse arrival time, heart rate, and variability; Res_BP and TCN_BP additionally process PPG signals. Subject-wise splits prevent data leakage, and calibration is applied using three to nine initial reference measurements per subject. Models trained on VitalDB consistently outperform those trained on MIMIC III, particularly for systolic BP, underscoring the importance of synchronized signals. Subject-specific calibration improves performance, with diminishing returns beyond three measurements. Calibrated models reach clinically acceptable accuracy for diastolic BP, while systolic BP remains challenging using PPG alone. These findings suggest that dataset integrity and proper calibration may matter more than model architecture in cuffless BP estimation.
Verbatim fromthe publisher's DOI record· Publisher licence: https://creativecommons.org/licenses/by/4.0

How it works
Datasets used· 1
Cite
@article{datasetintegritycalibrat2026,
title = {{The role of dataset integrity, calibration and signal quality in neural network-based blood pressure estimation}},
author = {Christian Fritzsche and Veit Senner (Technical University of Munich)},
year = {2026},
journal = {Scientific Reports},
doi = {10.1038/s41598-026-66882-7}
}History
Added to the ChatPPG research hub
More on ChatPPG
- LIMA-Mamba: A lightweight and distribution-robust Mamba network for PPG-based biometrics
From the title only, it is a Mamba (selective state-space) network for PPG-based biometric recogniti
- A Comparative Study of Signal Representations Methods and Deep Learning Architectures for PPG-Based Cuffless Blood Pressure Estimation
Seven 1D→2D transforms × several CNN variants on the UCI BP database. Best: CWT, errors reported as
- A meta-learning method with reduced data requirements for training and updating deep learning models on wearable devices
This paper proposes a meta-learning method that cuts how much labelled data a new wearable needs bef