Paperdoi:10.1038/s41598-017-11507-3

Pulse transit time based continuous cuffless blood pressure estimation: a new extension and a comprehensive evaluation

Venue listed2017Added Oct 29, 2026

  • XD
  • BY
  • YZ
  • JL
  • NZ
  • HT

Authors: Xiaorong Ding, Bryan P. Yan, Yuan‐Ting Zhang, Jing Liu, Ni Zhao, Hon Ki Tsang

Sci. Rep. 2017;7:11554

TL;DR

Adds the PPG intensity ratio (PIR) to pulse transit time (PTT) for cuffless BP and compares it against six PTT-only models. The test covered 33 subjects with and without hypertension, at rest, during BP-changing maneuvers and over a 24-hour calibration interval. PTT+PIR beat PTT-only at rest and over 24 h, but every method lost accuracy during dynamic maneuvers and over longer calibration intervals.

  • Form factor: finger + ECG

Abstract

Cuffless technique enables continuous blood pressure (BP) measurement in an unobtrusive manner, and thus has the potential to revolutionize the conventional cuff-based approaches. This study extends the pulse transit time (PTT) based cuffless BP measurement method by introducing a new indicator – the photoplethysmogram (PPG) intensity ratio (PIR). The performance of the models with PTT and PIR was comprehensively evaluated in comparison with six models that are based on sole PTT. The validation conducted on 33 subjects with and without hypertension, at rest and under various maneuvers with induced BP changes, and over an extended calibration interval, respectively. The results showed that, comparing to the PTT models, the proposed methods achieved better accuracy on each subject group at rest state and over 24 hours calibration interval. Although the BP estimation errors under dynamic maneuvers and over extended calibration interval were significantly increased for all methods, the proposed methods still outperformed the compared methods in the latter situation. These findings suggest that additional BP-related indicator other than PTT has added value for improving the accuracy of cuffless BP measurement. This study also offers insights into future research in cuffless BP measurement for tracking dynamic BP changes and over extended periods of time.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Blood pressurePulse arrival time

Signals

Keywords

Cuffless BPPTTPIRCalibration

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG); Form factor (finger + ECG). Method: Method. Target: Blood pressure; Pulse arrival time.SetupSignals: PPGSignalsPPGForm factor: finger + ECGForm factorfinger + ECGMethodMethodTargetBlood pressureBlood pressurePulse arrival timePulse arrival time

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Pulse transit time based continuous cuffless blood pressure estimation: a new extension and a comprehensive evaluation. (2017). Sci. Rep. 2017, 7, 11554. https://doi.org/10.1038/s41598-017-11507-3
@article{dingzhangpttpirc2017pulse,
  title         = {{Pulse transit time based continuous cuffless blood pressure estimation: a new extension and a comprehensive evaluation}},
  year          = {2017},
  journal       = {Sci. Rep. 2017},
  volume        = {7},
  pages         = {11554},
  doi           = {10.1038/s41598-017-11507-3}
}

Added to the ChatPPG research hub