PaperarXiv:2605.22774
CogAdapt: Adapting Clinical ECG Foundation Models for Wearable Cognitive Load Assessment
arXiv preprint
Key results
All results0.626
Macro F1 ↑
Cognitive load · CLARE
adapted clinical ECG foundation model
0.768
Macro F1 ↑
Cognitive load · CL-Drive
adapted clinical ECG foundation model
Results as reported by the authors; not independently reproduced. A SOTA star marks the best value among results reported under the same evaluation protocol; ties go to the earlier publication.
TL;DR
This paper presents CogAdapt, which adapts a clinical ECG foundation model to estimate cognitive load from wearable ECG. Its ProFine strategy unfreezes encoder layers in stages to limit drift. On CLARE and CL-Drive with leave-one-subject-out testing it reached macro-F1 of 0.626 and 0.768, 11.2 and 16.1 points above models trained from scratch.
- Result: On two public datasets (CLARE and CL-Drive) under leave-one-subject-out cross-validation, CogAdapt reaches macro-F1 of 0.626 and 0.768, improving over from-scratch baselines by 11.2 and 16.1 percentage points.
Abstract
Assessing cognitive load continuously and at low latency would help adaptive human-computer interaction, but it remains hard because labeled data are scarce and models generalize poorly across subjects. Recent ECG foundation models, pre-trained on millions of clinical diagnostic ECG recordings, yet they do not apply directly to wearable devices when the sensor configuration and the task both differ. We present CogAdapt, a framework that adapts a clinical ECG foundation model to wearable cognitive load assessment. CogAdapt has two parts. LeadBridge is a learnable adapter that maps 3-lead wearable signals to a 12-lead-compatible representation. ProFine is a progressive fine-tuning strategy that unfreezes encoder layers in stages while limiting representational drift in the pre-trained model. On two public datasets (CLARE and CL-Drive) under leave-one-subject-out cross-validation, CogAdapt reaches macro-F1 of 0.626 and 0.768, improving over from-scratch baselines by 11.2 and 16.1 percentage points. The results show that a clinical ECG pretraining can support subject-independent cognitive load assessment from wearable sensors.
Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
Models
How it works
Cite this paper
Mousavi, A., Nourbakhsh, E., Sirjani, M. S., Xie, M., Slavin, R., Neely, L., Davis, J., & Quarles, J. (2026). CogAdapt: Adapting Clinical ECG Foundation Models for Wearable Cognitive Load Assessment. arXiv preprint. https://arxiv.org/abs/2605.22774
Mousavi, Amir, Erfan Nourbakhsh, Mohammad Sadegh Sirjani, Mimi Xie, Rocky Slavin, Leslie Neely, John Davis, and John Quarles. 2026. "CogAdapt: Adapting Clinical ECG Foundation Models for Wearable Cognitive Load Assessment." arXiv preprint. https://arxiv.org/abs/2605.22774.
Mousavi, A., Nourbakhsh, E., Sirjani, M. S., Xie, M., Slavin, R., Neely, L., Davis, J. and Quarles, J. (2026) 'CogAdapt: Adapting Clinical ECG Foundation Models for Wearable Cognitive Load Assessment', arXiv preprint. Available at: https://arxiv.org/abs/2605.22774
Mousavi, Amir, et al. "CogAdapt: Adapting Clinical ECG Foundation Models for Wearable Cognitive Load Assessment." arXiv preprint, 2026. https://arxiv.org/abs/2605.22774.
A. Mousavi et al., "CogAdapt: Adapting Clinical ECG Foundation Models for Wearable Cognitive Load Assessment," arXiv preprint, 2026, [Online]. Available: https://arxiv.org/abs/2605.22774.
@misc{mousavi2026cogadapt,
title = {{CogAdapt: Adapting Clinical ECG Foundation Models for Wearable Cognitive Load Assessment}},
author = {Mousavi, Amir and Nourbakhsh, Erfan and Sirjani, Mohammad Sadegh and Xie, Mimi and Slavin, Rocky and Neely, Leslie and Davis, John and Quarles, John},
year = {2026},
howpublished = {arXiv preprint},
eprint = {2605.22774},
archivePrefix = {arXiv}
}Added to the ChatPPG research hub