TL;DR

The KubiosHRV app's smartphone-accelerometer HRV feature (iPhone 14) was compared with a Polar H10 chest strap in 52 people across performance tiers, using the second minute of a 2-minute rest in supine, seated and standing positions. Time-domain and non-linear measures agreed closely (ICC ≥ 0.985, no proportional bias), while frequency-domain measures showed larger errors.

  • Form factor: smartphone accelerometer vs Polar H10

Abstract

Heart rate variability (HRV) is widely used to monitor athlete recovery and adaptation. Recent technological advances have enabled HRV assessment through smartphone applications without the need for external devices. This study aimed to assess the concurrent agreement between the accelerometer-based HRV measurement feature of the KubiosHRV app and the Polar H10 in supine, seated, and standing positions. A total of 52 participants (30 males and 22 females) across performance tiers 0–4 completed a 2 min resting recording, with the first minute discarded and the second minute analysed in each position. HRV was measured simultaneously using a Polar H10 chest strap and the accelerometer-based feature of the KubiosHRV app on an iPhone 14. The analysed variables included Mean RR, RMSSD, SDNN, LF power, HF power, SD1, and SD2. Data were automatically processed by the KubiosHRV app and manually extracted into a database. Results showed excellent intraclass correlation coefficients (≥0.985) and small magnitudes of error for time-domains and non-linear variables in the three analysed positions with the reference criterion. Frequency-domain variables showed larger error estimates. Bland–Altman analysis showed no evidence of proportional bias across the measurement range (p > 0.05). These findings suggest that, during 1 min recordings, the accelerometer-based feature of the KubiosHRV app showed strong concurrent agreement with the Polar H10 for time-domain variables and acceptable agreement for selected non-linear variables across positions. Therefore, it may represent a practical alternative for routine monitoring of these HRV metrics when external hardware is unavailable.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Signals

Keywords

HRVRMSSDSDNNAccelerometerKubiosHRVPolar H10AgreementAthletes

How it works

How Method works: Setup → Method → TargetSetup: Signals (accelerometer (smartphone on chest, seismocardiographic), ECG chest strap (reference)); Form factor (smartphone accelerometer vs Polar H10). Method: Method.SetupSignals: accelerometer (smartphone on chest, seismocardiographic), ECG chest strap (reference)xyzSignalsaccelerometer (smartphone on chest…Form factor: smartphone accelerometer vs Polar H10Form factorsmartphone accelerometer vs Polar H10MethodMethod

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Cervantes-Mugüerza, A., Martínez-Cava, A., Pallarés, J. G., Conesa-Ros, E., & Ruiz-Navarro, J. J. (2026). Smartphone Accelerometer Assessment of HRV: Concurrent Agreement of the KubiosHRV App. Sensors, 26(21), 6837. https://doi.org/10.3390/s26216837
Cervantes-Mugüerza, Alfonso, Alejandro Martínez-Cava, Jesús G. Pallarés, Elena Conesa-Ros, and Jesús Juan Ruiz-Navarro. 2026. "Smartphone Accelerometer Assessment of HRV: Concurrent Agreement of the KubiosHRV App." Sensors 26 (21): 6837. https://doi.org/10.3390/s26216837.
Cervantes-Mugüerza, A., Martínez-Cava, A., Pallarés, J. G., Conesa-Ros, E. and Ruiz-Navarro, J. J. (2026) 'Smartphone Accelerometer Assessment of HRV: Concurrent Agreement of the KubiosHRV App', Sensors, 26(21), p. 6837. doi: 10.3390/s26216837.
Cervantes-Mugüerza, Alfonso, et al. "Smartphone Accelerometer Assessment of HRV: Concurrent Agreement of the KubiosHRV App." Sensors, vol. 26, no. 21, 2026, p. 6837. https://doi.org/10.3390/s26216837.
A. Cervantes-Mugüerza, A. Martínez-Cava, J. G. Pallarés, E. Conesa-Ros, and J. J. Ruiz-Navarro, "Smartphone Accelerometer Assessment of HRV: Concurrent Agreement of the KubiosHRV App," Sensors, vol. 26, no. 21, p. 6837, 2026, doi: 10.3390/s26216837.
@article{cervantesmuguerza2026smartphone,
  title         = {{Smartphone Accelerometer Assessment of HRV: Concurrent Agreement of the KubiosHRV App}},
  author        = {Cervantes-Mugüerza, Alfonso and Martínez-Cava, Alejandro and Pallarés, Jesús G. and Conesa-Ros, Elena and Ruiz-Navarro, Jesús Juan},
  year          = {2026},
  journal       = {Sensors},
  volume        = {26},
  number        = {21},
  pages         = {6837},
  doi           = {10.3390/s26216837}
}

Added to the ChatPPG research hub