Activity counts measure attention, not model quality. Missing counts are unknown. Publication status follows the linked source; a listed venue alone does not confirm peer review.
Not a new foundation model: these are the exact checkpoints used in the paper, fine-tuning three existing open ECG FMs (ecg-fm, hubert-ecg, ecgfounder) for 26-label multi-label 12-lead diagnosis on PhysioNet/CinC 2021, then testing transfer to young competitive athletes, where physiological "athlete's heart" findings (sinus bradycardia, sinus arrhythmia, incomplete RBBB) are common. Each checkpoint is a PyTorch statedict (bestmodel.pth, best validation AUROC; seed not fixed, so retraining gives similar but not identical models).
Signals
ECG
Form factor
clinical 12-lead resting ECG
Year
2026
Architecture
Three fine-tunes of existing ECG FMs with a 26-logit multi-label head: ECG-FM (wav2vec2/CMSC-style transformer, mimic_iv_ecg_physionet_pretrained.pt, full fine-tune); HuBERT-ECG small (conv feature extractor frozen, last 8 transformer blocks + head trained); ECGFounder (Net1D CNN, 12_lead_ECGFounder.pth, full fine-tune). Architecture class reflects two of three; ECGFounder is a CNN.
Pretraining data
Fine-tuned on PhysioNet/CinC Challenge 2021 training data: 87,662 recordings after preprocessing (PTB and St. Petersburg INCART subsets excluded), 80/10/10 label-stratified split. Base-model pretraining is unchanged: ECG-FM, a transformer pretrained with contrastive augmentation and masked reconstruction (the paper reports 2.5M samples from 1.66M ECGs, public plus private UHN data; the checkpoint used here is the public-data release mimicivecgphysionetpretrained.pt); HuBERT-ECG small, self-supervised masked discrete-token prediction on 9.1M ECGs from four countries; ECGFounder, supervised pretraining on HEEDB, 10,771,552 ECGs from 1,818,247 subjects with 150 cardiologist diagnostic categories.
License
mixed: ECG-FM and ECGFounder fine-tunes MIT; HuBERT-ECG (small) fine-tune CC BY-NC 4.0
Three fine-tunes of existing ECG FMs with a 26-logit multi-label head: ECG-FM (wav2vec2/CMSC-style transformer, mimic_iv_ecg_physionet_pretrained.pt, full fine-tune); HuBERT-ECG small (conv feature extractor frozen, last 8 transformer blocks + head trained); ECGFounder (Net1D CNN, 12_lead_ECGFounder.pth, full fine-tune). Architecture class reflects two of three; ECGFounder is a CNN.
Venue
npj Digital Medicine 9, 920 (2026), published 2026-11-21, CC BY 4.0
AI-powered cardiac screening could evolve sports medicine by boosting accuracy, efficiency, and cost-effectiveness, with automated ECG interpretation based on foundation models becoming key for large-scale athlete screening. Before deployment, it is crucial to verify whether these clinically developed models are applicable to this population. We evaluated whether ECG foundation models trained on general clinical populations can diagnose athlete-specific ECG findings. We fine-tuned three models (ECG-FM, HuBERT-ECG, ECGFounder) on PhysioNet/CinC 2021, 87,662 samples, and tested them on 43 expert-annotated ECGs from highly trained/national-level athletes. Performance was strong on PhysioNet/CinC 2021 (AUROC 0.97, AUPRC 0.57, Sensitivity 0.89) but dropped on athletes’ data, confirming domain shift. ECGFounder performed best (AUROC 0.84, AUPRC 0.72, Sensitivity 0.57) and detected the most frequent findings, Sinus Bradycardia (AUROC 0.87) and Sinus Arrhythmia (AUROC 0.95), well. Per-label estimates for rare classes must be interpreted cautiously, given the small cohort. This work contributes to developing athlete-focused AI frameworks for reliable ECG-based screening.
Datasets linked in the hub; pretraining vs evaluation roles follow the paper.
Pretraining data
Fine-tuned on PhysioNet/CinC Challenge 2021 training data: 87,662 recordings after preprocessing (PTB and St. Petersburg INCART subsets excluded), 80/10/10 label-stratified split. Base-model pretraining is unchanged: ECG-FM, a transformer pretrained with contrastive augmentation and masked reconstruction (the paper reports 2.5M samples from 1.66M ECGs, public plus private UHN data; the checkpoint used here is the public-data release mimicivecgphysionetpretrained.pt); HuBERT-ECG small, self-supervised masked discrete-token prediction on 9.1M ECGs from four countries; ECGFounder, supervised pretraining on HEEDB, 10,771,552 ECGs from 1,818,247 subjects with 150 cardiologist diagnostic categories.
Architecture
Three fine-tunes of existing ECG FMs with a 26-logit multi-label head: ECG-FM (wav2vec2/CMSC-style transformer, mimic_iv_ecg_physionet_pretrained.pt, full fine-tune); HuBERT-ECG small (conv feature extractor frozen, last 8 transformer blocks + head trained); ECGFounder (Net1D CNN, 12_lead_ECGFounder.pth, full fine-tune). Architecture class reflects two of three; ECGFounder is a CNN.
Inputs
ECG
Approach
ecg · 12 lead · ecg fm · hubert ecg · ecgfounder · fine tune
Cite the publication recorded for this model. Check it against the publisher before submitting.
Goelz, C., Lang, S., Schlichtiger, J., Brunner, S., & Vieluf, S. (2026). ECG foundation models for cardiovascular screening in a cohort of young competitive athletes. npj Digital Medicine 9, 920. https://doi.org/10.1038/s41746-026-03474-9
Goelz, Christian, Simon Lang, Jenny Schlichtiger, Stefan Brunner, and Solveig Vieluf. 2026. "ECG foundation models for cardiovascular screening in a cohort of young competitive athletes." npj Digital Medicine 9, 920. https://doi.org/10.1038/s41746-026-03474-9.
Goelz, C., Lang, S., Schlichtiger, J., Brunner, S. and Vieluf, S. (2026) 'ECG foundation models for cardiovascular screening in a cohort of young competitive athletes', npj Digital Medicine 9, 920. doi: 10.1038/s41746-026-03474-9.
Goelz, Christian, et al. "ECG foundation models for cardiovascular screening in a cohort of young competitive athletes." npj Digital Medicine 9, 920, 2026. https://doi.org/10.1038/s41746-026-03474-9.
C. Goelz, S. Lang, J. Schlichtiger, S. Brunner, and S. Vieluf, "ECG foundation models for cardiovascular screening in a cohort of young competitive athletes," npj Digital Medicine 9, 920, 2026, doi: 10.1038/s41746-026-03474-9.
@article{goelz2026foundation,
title = {{ECG foundation models for cardiovascular screening in a cohort of young competitive athletes}},
author = {Goelz, Christian and Lang, Simon and Schlichtiger, Jenny and Brunner, Stefan and Vieluf, Solveig},
year = {2026},
journal = {npj Digital Medicine 9, 920},
doi = {10.1038/s41746-026-03474-9}
}
History
Added to the ChatPPG research hub
Newsletter
Get new PPG datasets, papers and models
Get alerts when AIBAT-LMU ECG FM athletes fine-tunes is benchmarked on new datasets, plus the weekly digest.
New datasets, papers and models
Practical guides from the hub
Unsubscribe anytime
The waveform is an illustration of a PPG pulse, not a recording.