Paperdoi:10.1038/s41598-026-80803-8

Assessment of the MOMENTUM sport earbud for multi-parametric physiological tracking and exploratory lactate modeling during incremental exercise (Camargo et al., Sci Rep 2026)

Venue listedDated Nov 20, 2026Added Nov 24, 2026

  • CS
  • ZC
  • WC
  • ST

Authors: Camargo D (TUM + cosinuss° Research & Science), Zellhuber I (cosinuss°), Weber M (cosinuss°), Schönfelder M (TUM)

Scientific Reports 16:38902 (2026); online 2026-11-20

TL;DR

Thirty-six adults did an incremental cycling ramp wearing Sennheiser MOMENTUM Sport earbuds. Earbud heart rate matched a Polar H10 chest strap closely (MAE 0.89 bpm, bias 0.79 bpm, LoA −0.73 to 2.30 bpm, n = 35). Ear-canal temperature agreed with a tympanic infrared thermometer (MAE 0.35 °C, LoA −0.72 to 0.95 °C, n = 23), but that reference is not a true core measure.

Abstract

Continuous monitoring of heart rate (HR) and core temperature (

T_c

) is essential for optimizing athletic performance and preventing heat-related illness. However, traditional monitoring methods like chest straps and wrist-worn trackers often face accuracy challenges during exercise due to sweat, motion, and signal interference. Furthermore, few devices offer validated, synchronized HR and

T_c

monitoring during physical exertion. This study validates the MOMENTUM Sport (MSPORT) earbud, a novel multisensor wearable for synchronized HR and

T_c

tracking and investigates its utility in non-invasive blood lactate prediction. Thirty-six healthy adults (19 males, 17 females) performed an incremental cycling ramp test under controlled laboratory conditions. MSPORT HR and

T_c

were validated against Polar H10 and Braun ThermoScan 7 references. Predictive lactate modeling was implemented via a Leave-One-Subject-Out (LOSO) framework, with physiological significance assessed through Linear Mixed Models (LMM) and temporal coupling via cross-correlation analysis. MSPORT showed good inter-device agreement for HR (MAE: 0.89 bpm; RMSE: 1.10 bpm) compared to the Polar H10, and good ear-canal temperature agreement with the Braun ThermoScan 7 (MAE: 0.35

^

C; MAPE: 0.92%). The lactate prediction model achieved a correlation of

R = 0.84

(

$p

), with LMM confirming

T_c

as a highly significant independent predictor (

= 11.63

, SE = 1.00,

z = 11.65

,

p

, 95% CI [9.68, 13.59]), while HR also contributed significantly (

= -1.94

, SE = 0.29,

z = -6.78

,

$p

). The negative HR coefficient likely reflects collinearity or a suppression effect: once cumulative

T_c

accounts for the metabolic trend, HR becomes a corrective term. Sex was a significant covariate (

= -1.25

,

z = -2.00

,

p = 0.046

). The random intercept variance was 1.909, indicating substantial between-participant variability in baseline lactate (model converged; REML). An exploratory cross-correlation analysis suggested a preliminary temporal association between lactate and ear-canal temperature; the precise lag magnitude cannot be reliably estimated from three-minute lactate sampling intervals. Absolute lactate magnitude showed significant sex-based differences (

$$p

). The MSPORT earbud provides reliable HR tracking and good ear-canal temperature agreement with a co-located tympanic reference during laboratory cycling. The exploratory lactate model demonstrates group-level association (

R = 0.84

) and supports the feasibility of thermal-cardiac signal fusion for metabolic monitoring, though individual-level accuracy remains insufficient for clinical use. Further research is required to assess performance across diverse exercise protocols, environments, and populations.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Heart rate

Signals

Keywords

ValidationHeart RateIn EarEarbudEar Canal TemperatureLactateCyclingBland Altman

How it works

How Method works: Setup → Method → TargetSetup: Signals (ppg, temperature). Method: Method. Target: Heart rate.SetupSignals: ppg, temperatureSignalsppg, temperatureMethodMethodTargetHeart rateHeart rate

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Camargo, D., Zellhuber, I., Weber, M., & Schönfelder, M. (2026). Assessment of the MOMENTUM sport earbud for multi-parametric physiological tracking and exploratory lactate modeling during incremental exercise (Camargo et al., Sci Rep 2026). Scientific Reports, 16, 38902. https://doi.org/10.1038/s41598-026-80803-8
Camargo, D, I Zellhuber, M Weber, and M Schönfelder. 2026. "Assessment of the MOMENTUM sport earbud for multi-parametric physiological tracking and exploratory lactate modeling during incremental exercise (Camargo et al., Sci Rep 2026)." Scientific Reports 16: 38902. https://doi.org/10.1038/s41598-026-80803-8.
Camargo, D., Zellhuber, I., Weber, M. and Schönfelder, M. (2026) 'Assessment of the MOMENTUM sport earbud for multi-parametric physiological tracking and exploratory lactate modeling during incremental exercise (Camargo et al., Sci Rep 2026)', Scientific Reports, 16, p. 38902. doi: 10.1038/s41598-026-80803-8.
Camargo, D, et al. "Assessment of the MOMENTUM sport earbud for multi-parametric physiological tracking and exploratory lactate modeling during incremental exercise (Camargo et al., Sci Rep 2026)." Scientific Reports, vol. 16, 2026, p. 38902. https://doi.org/10.1038/s41598-026-80803-8.
D. Camargo, I. Zellhuber, M. Weber, and M. Schönfelder, "Assessment of the MOMENTUM sport earbud for multi-parametric physiological tracking and exploratory lactate modeling during incremental exercise (Camargo et al., Sci Rep 2026)," Scientific Reports, vol. 16, p. 38902, 2026, doi: 10.1038/s41598-026-80803-8.
@article{camargo2026assessment,
  title         = {{Assessment of the MOMENTUM sport earbud for multi-parametric physiological tracking and exploratory lactate modeling during incremental exercise (Camargo et al., Sci Rep 2026)}},
  author        = {Camargo, D. and Zellhuber, I. and Weber, M. and Schönfelder, M.},
  year          = {2026},
  journal       = {Scientific Reports},
  volume        = {16},
  pages         = {38902},
  doi           = {10.1038/s41598-026-80803-8}
}

Added to the ChatPPG research hub